Publications by authors named "Francesca Campanelli"

Background: Posterior wall ablation (PWA) is commonly added to pulmonary vein isolation (PVI) during catheter ablation (CA) of persistent atrial fibrillation (AF).

Objective: The purpose of this study was to compare PVI plus PWA using very-high-power short-duration (vHPSD) vs standard-power (SP) ablation index-guided CA among consecutive patients with persistent AF and to determine the voltage correlation between microbipolar and bipolar mapping in AF.

Methods: We compared 40 patients undergoing PVI plus PWA using vHPSD to 40 controls receiving PVI plus PWA using SP.

View Article and Find Full Text PDF

Background: Pulsed field ablation (PFA) and very high-power short-duration (vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA vs vHPSD are currently unknown.

Objective: The study aimed to compare PFA with vHPSD for the treatment of paroxysmal or persistent AF.

View Article and Find Full Text PDF
Article Synopsis
  • * A total of 79 patients underwent ablation, showing a high percentage of PVC reduction, with athletes experiencing a reduction similar to non-athletes: median decrease of 98% for both groups.
  • * The results indicated that a significant number of athletes were able to return to their physical activities after 3 months, with many reporting symptom improvement after the procedure, confirming that PVC CA is effective and safe for athletes.
View Article and Find Full Text PDF

Background: Several novel technologies allowing catheter ablation (CA) with a favorable safety/efficacy profile have been recently developed, but not yet extensively clinically tested in the setting of ventricular tachycardia CA.

Methods: In this technical report, we overview technical aspects and preclinical/clinical information concerning the application of three novel CA technologies in the ventricular milieu: a pulsed field ablation (PFA) generator (CENTAURI™, Galaxy Medical) to be used with linear, contact force-sensing radiofrequency ablation catheters; a contact force-sensing radiofrequency ablation catheter equipped with six thermocouples and three microelectrodes (QDOT Micro™, Biosense-Webster), allowing high-resolution mapping and temperature-controlled CA; and a flexible and mesh-shaped irrigation tip, contact force-sensing radiofrequency ablation catheter (Tactiflex, Abbott). We also report three challenging VT cases in which CA was performed using these technologies.

View Article and Find Full Text PDF

Background: The clinical performance of high-power, short-duration (HPSD) pulmonary vein isolation (PVI) with the novel flexible tip TactiFlex™ (TFSE) catheter, as compared to standard-power, long-duration (SPLD) PVI using the TactiCath™ (TCSE) catheter among patients undergoing catheter ablation (CA) of atrial fibrillation (AF) is currently unknown.

Methods: We conducted a prospective, observational, single-centre study including 40 consecutive patients undergoing PVI for paroxysmal/persistent AF, using HPSD ablation with the novel TFSE catheter (HPSD/TFSE group). Based on propensity score-matching, forty patients undergoing SPLD PVI with the TCSE catheter were identified (SPLD/TCSE group).

View Article and Find Full Text PDF