To be accurate and equivalent among assays, laboratory results should be traceable to higher-order references and their quality should fulfill maximum allowable measurement uncertainty (MU) as defined to fit the intended clinical use. Accordingly, laboratory professionals should estimate and validate MU of performed tests using appropriate analytical performance specifications (APS). Current consensus supports the derivation of APS by using one of the three models established by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Strategic Conference held in Milan in 2014.
View Article and Find Full Text PDFFrom External Quality Assessment data, current harmonization of CRP measuring systems appears to be satisfactory, the inter-assay CV being well below 10%. The inter-method variability is even better (close to 3%) when the widely used measuring systems are compared at CRP concentrations employed as cut-off for detecting sub-clinical infection (i.e.
View Article and Find Full Text PDFLaboratories should estimate and validate [using analytical performance specifications (APS)] the measurement uncertainty (MU) of performed tests. It is therefore essential to appropriately define APS for MU, but also to provide a perspective on suitability of the practical application of these APS. In this study, 23 commonly ordered measurands were allocated to the models defined during the 2014 EFLM Strategic Conference to derive APS for MU.
View Article and Find Full Text PDFBackground: Serum ferritin is considered a suitable biomarker of iron-related disorders. However, data about the comparability of results among commercial measuring systems (MSs) are contradictory. We performed an intercomparison study aimed at verifying the current interassay variability and its impact on clinical application of the test.
View Article and Find Full Text PDFAlthough being the recommended laboratory test to diagnose acute pancreatitis, serum pancreatic lipase (LIP) is among the poorly standardized laboratory tests, and laboratory stakeholders often appear to not take enough care of the quality of its measurements. Here we discuss some important issues that, if not correctly managed and solved, make misdiagnosis of acute pancreatitis by using serum LIP a real possibility. First, the current unavailability of a suitable higher-order reference material to be used as common calibrator should be filled up to definitively improve the inter-method bias.
View Article and Find Full Text PDFTumors often show intra-tumor heterogeneity because of genotypic differences between all the cells that compose it and that derive from it. Recent studies have shown significant aspects of neuroblastoma heterogeneity that may affect the diagnostic-therapeutic strategy. Therefore, we developed a laboratory protocol, based on the combination of the advanced dielectrophoresis-based array technology and next-generation sequencing to identify and sort single cells individually and carry out their copy number variants analysis.
View Article and Find Full Text PDFBackground: Among the factors causing male infertility, one of the most debated is the exposure to environmental contaminants. Recently, the chemical compound Bisphenol A (BPA) has drawn attention from the reproductive science community, due to its ubiquitous presence in day-to-day life. Its toxic action appears to mainly affect the male reproductive system, directly impacting male fertility.
View Article and Find Full Text PDF