Publications by authors named "Franceries X"

Convolutional neural networks (CNNs) are gradually being recognized in the neuroimaging community as a powerful tool for image analysis. Despite their outstanding performances, some aspects of CNN functioning are still not fully understood by human operators. We postulated that the interpretability of CNNs applied to neuroimaging data could be improved by investigating their behavior when they are fed data with known characteristics.

View Article and Find Full Text PDF

Purpose: To develop an alternative computational approach for EPID-based non-transit dosimetry using a convolutional neural network model.

Method: A U-net followed by a non-trainable layer named True Dose Modulation recovering the spatialized information was developed. The model was trained on 186 Intensity-Modulated Radiation Therapy Step & Shot beams from 36 treatment plans of different tumor locations to convert grayscale portal images into planar absolute dose distributions.

View Article and Find Full Text PDF

Background: There is an unfulfilled need to find the best way to automatically capture, analyze, organize, and merge structural and functional brain magnetic resonance imaging (MRI) data to ultimately extract relevant signals that can assist the medical decision process at the bedside of patients in postanoxic coma. We aimed to develop and validate a deep learning model to leverage multimodal 3D MRI whole-brain times series for an early evaluation of brain damages related to anoxoischemic coma.

Methods: This proof-of-concept, prospective, cohort study was undertaken at the intensive care unit affiliated with the University Hospital (Toulouse, France), between March 2018 and May 2020.

View Article and Find Full Text PDF

Purpose: Monte Carlo (MC) is the reference computation method for medical physics. In radiotherapy, MC computations are necessary for some issues (such as assessing figures of merit, double checks, and dose conversions). A tool based on GATE is proposed to easily create full MC simulations of the Varian TrueBeam STx.

View Article and Find Full Text PDF

Purpose: In modulated radiotherapy, breathing motion can lead to Interplay (IE) and Blurring (BE) effects that can modify the delivered dose. The aim of this work is to present the implementation, the validation and the use of an open-source Monte-Carlo (MC) model that computes the delivered dose including these motion effects.

Methods: The MC model of the Varian TrueBeam was implemented using GATE.

View Article and Find Full Text PDF

Purpose: This study aims at investigating the dosimetric characteristics of a Varian aS1000 EPID, focusing on its continuous acquisition mode under the challenging conditions that can be met in stereotactic radiotherapy verification.

Methods: An aS1000 EPID installed on a Varian TrueBeamSTx was irradiated with 6 and 10 MV unflattened and flattened photon beams. In order to avoid detector saturation, the source-to-detector distance (SDD) was set to 150 or 180 cm depending on the dose rate.

View Article and Find Full Text PDF

Purpose: To assess the accuracy of volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) when treating moving targets (such as lung or liver lesions), focusing on the impact of the interplay effect in the event of complex breathing motion and when a gating window is used.

Methods: A dedicated programmable motion platform was implemented. This platform can carry large quality assurance (QA) phantoms and achieve complex three-dimensional (3D) motion.

View Article and Find Full Text PDF

Astronauts are exposed to microgravity and chronic irradiation but experimental conditions combining these two factors are difficult to reproduce on earth. We have created an experimental device able to combine chronic irradiation and altered gravity that may be used for cell cultures or plant models in a ground based facility. Irradiation was provided by thorium nitrate powder, conditioned so as to constitute a sealed source that could be placed in an incubator.

View Article and Find Full Text PDF

Purpose: Commercial algorithms used in Radiotherapy include approximations that are generally acceptable. However their limits can be seen when confronted with small fields and low-density media. These conditions exist during the treatment of lung cancers with Stereotactic Body Radiation Therapy (SBRT) achieved with the "Deep Inspiration Breath Hold" (DIBH) technique.

View Article and Find Full Text PDF

A new alternative set of elastic and inelastic cross sections has been added to the very low energy extension of the Geant4 Monte Carlo simulation toolkit, Geant4-DNA, for the simulation of electron interactions in liquid water. These cross sections have been obtained from the CPA100 Monte Carlo track structure code, which has been a reference in the microdosimetry community for many years. They are compared to the default Geant4-DNA cross sections and show better agreement with published data.

View Article and Find Full Text PDF

The study of cell survival following exposure to nonuniform radiation fields is taking on particular interest because of the increasing evidence of a nonlinear relationship at low doses. We conducted in vitro experiments using the MCF7 breast cancer cell line. A 2.

View Article and Find Full Text PDF

Purpose: This work presents an original algorithm that converts the signal of an electronic portal imaging device (EPID) into absorbed dose in water at the depth of maximum.

Methods: The model includes a first image pre-processing step that accounts for the non-uniformity of the detector response but also for the perturbation of the signal due to backscatter radiation. Secondly, the image is converted into absorbed dose to water through a linear conversion function associated with a dose redistribution kernel.

View Article and Find Full Text PDF

The aim of this study is to evaluate microMOSFET as in-vivo dosimeter in 6 MV shaped-beam radiosurgery for field sizes down to 6 × 6 mm2. A homemade build-up cap was developed and its use with microMOSFET was evaluated down to 6 × 6 mm2. The study with the homemade build-up cap was performed considering its influence on field size over-cover occurring at surface, achievement of the overall process of electronic equilibrium, dose deposition along beam axis and dose attenuation.

View Article and Find Full Text PDF

The purpose of our work was to investigate the feasibility of using an EPID-based in-vivo dosimetry method initially designed for conformal fields on pelvic dynamic IMRT fields. The method enables a point dose delivered to the patient to be calculated from the transit signal acquired with an electronic portal imaging device (EPID). After defining a set of correction factors allowing EPID pixel values to be converted into absolute doses, several tests on homogeneous water-equivalent phantoms were performed to estimate the validity of the method in reference conditions.

View Article and Find Full Text PDF

Nowadays MOSFET dosimeters are widely used for dose verification in radiotherapy procedures. Although their sensitive area satisfies size requirements for small field dosimetry, their use in radiosurgery has rarely been reported. The aim of this study is to propose and optimize a calibration method to perform surface measurements in 6 MV shaped-beam radiosurgery for field sizes down to 18 × 18 mm(2).

View Article and Find Full Text PDF

Background: To integrate 3D MR spectroscopy imaging (MRSI) in the treatment planning system (TPS) for glioblastoma dose painting to guide simultaneous integrated boost (SIB) in intensity-modulated radiation therapy (IMRT).

Methods: For sixteen glioblastoma patients, we have simulated three types of dosimetry plans, one conventional plan of 60-Gy in 3D conformational radiotherapy (3D-CRT), one 60-Gy plan in IMRT and one 72-Gy plan in SIB-IMRT. All sixteen MRSI metabolic maps were integrated into TPS, using normalization with color-space conversion and threshold-based segmentation.

View Article and Find Full Text PDF

The T1 head template model used in Statistical Parametric Mapping Version 2000 (SPM2), was segmented into five layers (scalp, skull, CSF, grey and white matter) and implemented in 2 mm voxels. We designed a resistor mesh model (RMM), based on the finite volume method (FVM) to simulate the electrical properties of this head model along the three axes for each voxel. Then, we introduced four dipoles of high eccentricity (about 0.

View Article and Find Full Text PDF

Objective: We hypothesized that a single dose of methylphenidate (MP) would modulate cerebral motor activation and behavior in patients having suffered a subcortical stroke.

Methods: Eight men with a single stroke on the corticospinal tract resulting in a pure motor hemiparesia were included in a randomized, cross-over, double-blind, placebo-controlled study. Patients were first evaluated 17 days after stroke onset by validated neurological scales, motor tests and fMRI (flexion/extension of the digits) after 20 mg MP or placebo.

View Article and Find Full Text PDF

A resistor mesh model (RMM) has been validated with reference to the analytical model by consideration of a set of four dipoles close to the cortex. The application of the RMM to scalp potential interpolation was detailed in Part 1. Using the RMM and the same four dipoles, the different methods of cortical mapping were compared and have shown the potentiality of this RMM for obtaining current and potential cortical distributions.

View Article and Find Full Text PDF

A resistor mesh model (RMM) has been implemented to describe the electrical properties of the head and the configuration of the intracerebral current sources by simulation of forward and inverse problems in electroencephalogram/event related potential (EEG/ERP) studies. For this study, the RMM representing the three basic tissues of the human head (brain, skull and scalp) was superimposed on a spherical volume mimicking the head volume: it included 43 102 resistances and 14 123 nodes. The validation was performed with reference to the analytical model by consideration of a set of four dipoles close to the cortex.

View Article and Find Full Text PDF

Unlabelled: SSRIs are postulated to modulate motor behavior. A single dose of selective serotoninergic reuptake inhibitors (SSRIs) like fluoxetine, paroxetine, or fluvoxamine, has been shown to improve motor performance and efficiency of information processing for simple sensorimotor tasks in healthy subjects. At a cortical level, a single dose of SSRI was shown to induce a hyperactivation of the primary sensorimotor cortex (S1M1) involved in the movement (Loubinoux, I.

View Article and Find Full Text PDF

Studies investigating the cerebral areas involved in visual processes generally oppose either different tasks or different stimulus types. This work addresses, by fMRI, the interaction between the type of task (discrimination vs. categorization) and the type of stimulus (Latin letters, well-known geometrical figures, and Korean letters).

View Article and Find Full Text PDF

Bone thickness, anisotropy, and inhomogeneity have been reported to induce important variations in electroencephalogram (EEG) scalp potentials. To study this effect, we used an original three-dimensional (3-D) resistor mesh model described in spherical coordinates, consisting of 67,464 elements and 22,105 nodes arranged in 36 different concentric layers. After validation of the model by comparison with the analytic solution, potential variations induced by geometric and electrical skull modifications were investigated at the surface in the dipole plane and along the dipole axis, for several eccentricities and bone thicknesses.

View Article and Find Full Text PDF