Publications by authors named "Floriani F"

Purpose: The purpose of this study was to analyze gingival fibroblast proliferation on additively manufactured polymethylmethacrylate (PMMA) groups with different surface characteristics namely no treatment group (NTG) and customized 250 µm diameter porosity (AM-250G) group.

Materials And Methods: 3D-printed NTG was compared for its influence on growth of cells to a additively manufactured surface with porosity (AM-250G). For each group (NTG, AM-250G) 20 samples of material were tested.

View Article and Find Full Text PDF

Purpose: To evaluate the color match and stability of single-shade resin-based composites (RBCs) in Class V restorations before and after ultra-violet light artificial aging.

Methods: Acrylic resin teeth of A1 and A3 were randomly assigned into seven groups to be restored with single-shade RBCs and universal-shade RBCs, shades A1 and A3. Standardized Class V cavities were restored using RBC and underwent accelerated aging for 480 hours.

View Article and Find Full Text PDF

This case report features a female patient with the chief complaint of needing to replace an anterior crown. After a comprehensive oral assessment and cone beam computed tomography (CBCT) radiographic examination, it was determined that the crown on Tooth #9 was subgingivally fractured. The procedure involved atraumatic extraction of Tooth #9, followed by immediate implant placement.

View Article and Find Full Text PDF

Objectives: This case report describes the clinical protocols for the removal of crowns, tooth extraction, immediate implant placement, and cementation of new crowns, all performed under total or partial isolation with a dental dam.

Clinical Considerations: The patient's chief complaint was dissatisfaction with her smile. Radiographic and clinical evaluations led to the recommendation to replace the porcelain-fused-to-metal crowns on the maxillary central and lateral incisors with all-ceramic crowns.

View Article and Find Full Text PDF
Article Synopsis
  • This study assesses the fracture strength of implant-supported fixed dental prostheses (FDPs) made from 3D-printed resin, comparing those with and without fiber-reinforced composite (FRC) frameworks.
  • Forty FDPs were made in two types: monolithic (all resin) and bi-layer (resin with FRC framework), with testing conducted on aging and control samples to measure their resistance to bending.
  • Results showed that FDPs with the FRC framework had significantly higher fracture strength, while aging didn't affect strength but influenced failure patterns, mainly occurring at the connectors, especially in the premolar area.
View Article and Find Full Text PDF

Background: This study aimed to evaluate the color stability of bulk-fill flowable resin composites with 2 difference shades at baseline and after artificial aging.

Methods: Disk-shaped specimens (Ø10 × 4 mm) were fabricated from three bulk-fill flowable resin resin composites (Filtek Bulk-Fill Flow, Venus Bulk-Fill Flow, and Estelite Bulk-Fill Flow). The specimens in each bulk-fill resin composite group were divided into two subgroups (n = 10 per subgroup) with two different shades, A1 (N = 30) and A3 (N = 30), and were polymerized with light curing (800 mW/cm/Valo LED Unit, Ultradent) and polished.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the prevalence and severity of sleep bruxism (SB) in edentulous patients, who are those without natural teeth, using a definitive measurement method.* -
  • Conducted with 23 edentulous patients using new complete dentures, the research assessed SB through a portable device while patients slept at home.* -
  • Results showed that 78.26% of participants had SB, with 55.5% experiencing light bruxism and 39% showing moderate to severe cases.*
View Article and Find Full Text PDF

The esthetics of immediate implant dentistry can be challenging. Clinical considerations for immediate implant placement have demonstrated long-term success rates comparable to traditional delayed implant protocols. However, it is a sensitive technique that requires proper treatment planning as well as meticulous execution to be predictable and successful in the long term.

View Article and Find Full Text PDF

Aim: Current CAD/CAM techniques allow clinicians to design and 3D print tooth reduction guides that facilitate controlled preparations in the esthetic zone. The present case report describes the workflow for designing and printing a tooth reduction guide intended to assist ceramic veneer preparations. This 3D-printed guide divides the facial surface of the teeth into four areas and allows the measuring of all areas, including the incisal edge, with a periodontal probe.

View Article and Find Full Text PDF

This report describes multidisciplinary care combining orthodontics and restorative dentistry for a patient with Class II occlusion and stained mandibular and maxillary resin composite veneers. The orthodontic treatment improved severe overjet and malocclusion prior to restorative care. Occlusal assessment was provided with a novel digital device (PlaneSystem, Zirkonzahn) that is integrated with digital workflows for the evaluation of the occlusal plane and condylar path inclination.

View Article and Find Full Text PDF

Purpose: This systematic review and meta-analysis aimed to evaluate the depth distortion and angular deviation of fully-guided tooth-supported static surgical guides (FTSG) in partially edentulous arches compared to partially guided surgical guides or freehand.

Material And Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, and outcome (PICO) question was: "In partially edentulous arches, what are the depth distortion and angular deviation of FTSG compared to partially guided surgical guides or freehand?" The search strategy involved four main electronic databases, and an additional manual search was completed in November 2023 by following an established search strategy.

View Article and Find Full Text PDF

Background: To evaluate the effectiveness of three minimally invasive techniques for managing patients with myofascial pain dysfunction, determine their association with sociodemographic factors, habits, medication usage, comorbidities, treatment history, pain duration, complaint intensity, and diagnosis limitations.

Material And Methods: This five-year observational study scrutinized 1,000 medical records from individuals treated at the TMD Orofacial Dental Research Center. TMD treatments were organized into Group 1 (thermotherapy, exercises, and CBT), Group 2 (Group 1 plus intramuscular manual therapy), and Group 3 (Group 1 and Group 2 plus occlusal appliances) and correlated with sociodemographic factors, habits, prior medication usage, comorbidities, history of prior treatments, duration of pain, intensity of complaint, and diagnosis limitations or without limitations regarding the symptoms of muscular temporomandibular disorders (TMD).

View Article and Find Full Text PDF

Objectives: Conceptualizing the next patient interaction is logical, essential, and largely done intuitively with limited literature. The first objective is to elicit student thought experiences to four questions. The secondary objective is to classify responses for respective questions and to review faculty assessments.

View Article and Find Full Text PDF

Aim: This in vitro study aimed to compare the light-transmission properties of two chairside CAD/CAM lithium disilicate (LD) ceramics (a novel fully crystallized and a traditional pre-crystallized) across varying thicknesses.

Materials And Methods: One hundred flat specimens were obtained from precrystallized (e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and fully crystallized (LiSi GC Block; GC, Tokyo, Japan) LD at five different thicknesses (0.

View Article and Find Full Text PDF

Purpose: This systematic review aims to compare clinical outcomes of digital dentures with conventional dentures.

Materials And Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in Prospero. The formulated population, intervention, comparison, outcome (PICO) question was "What is the clinical outcome of digital versus conventional complete dentures (CDs) in edentulous patients?".

View Article and Find Full Text PDF

This case report details the esthetic rehabilitation of a 32-year-old male patient suffering from sleep bruxism, primarily manifesting as a fracture and significant loss of tooth structure in the anterior maxillary central incisors. To address these concerns, the patient underwent a restorative treatment involving the application of semidirect resin composite veneers on the maxillary incisors and direct resin composite restoration on the incisal regions of the maxillary canines. This approach not only restored the functional integrity of the teeth but also significantly enhanced the patient's esthetic appearance.

View Article and Find Full Text PDF

Background: We compared the repeatability of the shade determination of resin composite restorations and acrylic teeth in light and darker shades at baseline and after an aging process through two digital tooth color-matching methods: using a Trios 3Shape intraoral scanner and using a Vita Easyshade Compact spectrophotometer.

Material And Methods: Forty upper central incisor acrylic teeth in the shade A1 ( = 10) and A3 ( = 10) were randomly assigned to be restored with Filtek Bulk Fill in the shade A1 ( = 10) or A3 ( = 10). Subsequently, 20 Class V cavities were prepared in a standardized manner (mesio-distal = 3.

View Article and Find Full Text PDF

With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures.

View Article and Find Full Text PDF

Purpose: This systematic review was conducted to evaluate the prevalence of interproximal contact loss (ICL) between implant restorations and adjacent teeth in relation to age, gender, follow-up time, and arch location.

Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, outcome (PICO) question was "What is the prevalence of the ICL between implant restoration and adjacent teeth?" The search strategy used four main electronic databases and an additional manual search was performed until February 2023.

View Article and Find Full Text PDF

Liquid-liquid phase separation (LLPS) of biopolymers to form condensates is a widespread phenomenon in living cells. Agents that target or alter condensation can help uncover elusive physiological and pathological mechanisms. Owing to their unique material properties and modes of interaction with biomolecules, nanoparticles represent attractive condensate-targeting agents.

View Article and Find Full Text PDF

Deficit of human ornithine aminotransferase (hOAT), a mitochondrial tetrameric pyridoxal-5'-phosphate (PLP) enzyme, leads to gyrate atrophy of the choroid and retina (GA). Although 70 pathogenic mutations have been identified, only few enzymatic phenotypes are known. Here, we report biochemical and bioinformatic analyses of the G51D, G121D, R154L, Y158S, T181M, and P199Q pathogenic variants involving residues located at the monomer-monomer interface.

View Article and Find Full Text PDF

This article compares the accuracy of intraoral scanners (IOSs) used in the digital impression of full arches to fabricate implant-supported complete prostheses. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and was registered in the Open Science Framework (DOI 10.17605/OSF.

View Article and Find Full Text PDF

In Alzheimer's disease and related disorders called tauopathies, the microtubule-associated protein tau accumulates in the brain in the form of amyloid-like supramolecular filaments. As an intrinsically disordered protein, tau undergoes many post-translational modifications, including ubiquitination. Alterations to the levels of ubiquitination of tau have been observed at various stages of neurodegenerative conditions.

View Article and Find Full Text PDF

Objectives: To compare the degree of satisfaction (SD) and the impact on oral health-related quality of life (OHRQoL) of edentulous patients treated with conventional complete dentures (CCDs) and mandibular overdentures (IODs) with a short anteroposterior spread (S-APS) or a large antero-posterior spread (L-APS).

Materials And Methods: Edentulous patients were treated with CCDs and subsequently randomly allocated to receive a bar clip mandibular overdenture retained by 2 interforaminal implants (Control) or 4 (Test: 2 additional implants distal to the mental foramen). The Oral Health Impact Profile Edent questionnaire (OHIP-20E) and the Visual Analogue Scale (VAS) were applied at a mean follow-up of 38.

View Article and Find Full Text PDF

Background: The purpose of this in vitro study was to evaluate the color difference between the Vita Classical Shade Guide and composite veneers using the dual-layer technique.

Material And Methods: Thirty samples were fabricated using a custom-made mold (Easy Layering Shade Guide Kit, 3M) using two resin composites: Filtek Supreme Ultra (3M); and Estelite Omega (Tokuyama) (n=3). The composite veneers were made by layering the different enamel and body or dentin shades from each composite.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session221g7ovev3pc7o8ud1ldj11gc9ra4llr): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once