Publications by authors named "Florent Vanstapel"

Article Synopsis
  • The EN ISO 15189:2022 standard updates regulations for medical laboratories, replacing previous versions and aiming for better quality and competence.
  • The revision focuses on aligning with ISO/IEC 17025:2017, enhancing patient safety, and providing clearer guidelines while minimizing new requirements.
  • A guidance document from the EFLM Committee has been produced to help laboratories and accreditation bodies understand and implement these changes effectively.
View Article and Find Full Text PDF
Article Synopsis
  • Medical laboratories must document various activities to maintain service quality, leading to the generation of multiple documents, forms, and reports.
  • Each document's retention time must be specified, adhering to national laws or professional guidelines, with a defined retention schedule created when guidelines are lacking.
  • The EFLM Working Group offers recommendations for retention periods based on a risk-based approach (FMEA), aligning with ISO 15189:2022 for general quality management.
View Article and Find Full Text PDF

Objectives: According to ISO 15189:2022, analytical performance specifications (APS) should relate to intended clinical use and impact on patient care. Therefore, we aimed to develop a web application for laboratory professionals to calculate APS based on a simulation of the impact of measurement uncertainty (MU) on the outcome using the chosen decision limits, agreement thresholds, and data of the population of interest.

Methods: We developed the "APS Calculator" allowing users to upload and select data of concern, specify decision limits and agreement thresholds, and conduct simulations to determine APS for MU.

View Article and Find Full Text PDF
Article Synopsis
  • The EU Diagnostic Device Regulation (IVDR) emphasizes risk-based validation, traceability, and post-market monitoring of diagnostic devices while excluding medical services based on these devices.
  • Laboratory-developed tests (LDTs) can be used when commercial devices are unavailable, subjecting them to specific performance and safety guidelines under an ISO 15189-equivalent quality system.
  • The IVDR may lead to the disappearance of some commercial tests, necessitating urgent LDT replacements, while raising concerns about the potential loss of niche medical applications and increased costs within healthcare systems.
View Article and Find Full Text PDF

Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Laboratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use.

View Article and Find Full Text PDF

Laboratory medicine in the European Union is at the dawn of a regulatory revolution as it reaches the end of the transition from IVDD 98/79/EC (https://eur-lex.eur-opa.eu/legal-content/EN/TXT/?uri=CELEX%3A31998L0079&qid=1628781352814) to IVDR 2017/746 https://eur-lex.

View Article and Find Full Text PDF

The ISO 15189:2012 standard section 5.9.1 requires laboratories to review results before release, considering quality control, previous results, and clinical information, if any, and to issue documented procedures about it.

View Article and Find Full Text PDF

Background: There is a trend towards decentralisation of laboratory tests by means of Point-of-Care testing (POCT). Within hospitals, Belgian law requires a POCT policy, coordinated by the clinical laboratory. There is however no legal framework for POCT performed outside the hospital: no reimbursement, no compulsory quality monitoring and no limits nor control on the prices charged to the patient.

View Article and Find Full Text PDF

This paper reflects the opinion of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group Accreditation and ISO/CEN standards (WG-A/ISO). It aims to provide guidance for drawing up local/national documents about validation and verification of laboratory methods. We demonstrate how risk evaluation can be used to optimize laboratory policies to meet intended use requirements as well as requirements of standards.

View Article and Find Full Text PDF

ISO15189:2012 requires medical laboratories to document metrological traceability of their results. While the ISO17511:2003 standard on metrological traceability in laboratory medicine requires the use of the highest available level in the traceability chain, it recognizes that for many measurands there is no reference above the manufacturer's selected measurement procedure and the manufacturer's working calibrator. Some immunoassays, although they intend to measure the same quantity and may even refer to the same reference material, unfortunately produce different results because of differences in analytical selectivity as manufacturers select different epitopes and antibodies for the same analyte.

View Article and Find Full Text PDF

This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used.

View Article and Find Full Text PDF

Background: Accreditation is a valuable resource for medical laboratories. The development of quality systems based on ISO 15189 has taken place in many laboratories in the European countries but data about accreditation remain scarce. The EFLM Working Group "Accreditation and ISO/CEN standards" conducted a survey that reviews the current state of the accreditation process in European countries.

View Article and Find Full Text PDF

Background: We verified the analytical performance of strip-based handheld glucose meters (GM) for prescription use, in a comparative split-sample protocol using blood gas samples from a surgical intensive care unit (ICU).

Methods: Freestyle Precision Pro (Abbott), StatStrip Connectivity Meter (Nova), ACCU-CHEK Inform II (Roche) were evaluated for recovery/linearity, imprecision/repeatability. The GMs and the ABL90 (Radiometer) blood gas analyzer (BGA) were tested for relative accuracy vs.

View Article and Find Full Text PDF

The recent revision of ISO15189 has further strengthened its position as the standard for accreditation for medical laboratories. Both for laboratories and their customers it is important that the scope of such accreditation is clear. Therefore the European co-operation for accreditation (EA) demands that the national bodies responsible for accreditation describe the scope of every laboratory accreditation in a way that leaves no room for doubt about the range of competence of the particular laboratories.

View Article and Find Full Text PDF

Background: Systematic evidence of the contribution made by laboratory medicine to patient outcomes and the overall process of healthcare is difficult to find. An understanding of the value of laboratory medicine, how it can be determined, and the various factors that influence it is vital to ensuring that the service is provided and used optimally.

Content: This review summarizes existing evidence supporting the impact of laboratory medicine in healthcare and indicates the gaps in our understanding.

View Article and Find Full Text PDF

Background: With the use of a traditional blood gas analyzer (BGA) (ABL800 Radiometer) for blood glucose monitoring, tight glucose control (TGC) reduced in-hospital mortality and morbidity of surgical intensive care unit (ICU) adult and pediatric patients. Such BGAs are now superseded by cassette-based BGAs. We assessed the analytical reliability of cassette-based BGAs to monitor patient's metabolic status in an ICU setting.

View Article and Find Full Text PDF

1. Iodogen (tetrachloro-diphenyl glycoluril) dissolved in DMSO (dimethyl sulphoxide) appears indispensable in radioiodination of hypericin for a new anticancer strategy. We studied the safety of intravenously administered iodogen/DMSO in mice (n = 132).

View Article and Find Full Text PDF

Objective: Serum creatinine (Scr) reflects to a certain extent glomerular filtration rate in neonates, but postnatal observations also depends on the technique used to quantify Scr (Jaffe colorimetry or enzymatic quantification).

Methods: In an attempt to quantify differences between these techniques, we compared postnatal Scr trends in two consecutive cohorts of extremely low birth-weight (ELBW) neonates before and following a switch from uncompensated Jaffe to enzymatic Scr quantification. Postnatal Scr (Days 1, 2, 3, 4, 5, 6, 7, 8, 9, 14, 21, 28, and 42) in 151 ELBW neonates (uncompensated Jaffe) was compared to 116 more recently admitted ELBW neonates (enzymatic).

View Article and Find Full Text PDF