Annu Int Conf IEEE Eng Med Biol Soc
May 2012
In this paper, we propose the use of black box models for the system identification of the cardiopulmonary baroreflex control of arterial resistance and of ventricular contractility and of arterial baroreflex control of heart rate (HR) from invasive, continuous measurements of arterial blood pressure (ABP) and central venous pressure (CVP), and non invasive, continuous recordings of ECG and respiration. Two crucial phases of the abdominal aortic aneurism (AAA) repair were investigated: the clamping and declamping of aorta. The objective of the present work is to evaluate and to test the ability to monitor baroreflex responses to clamping and declamping maneuvers preceding and following aneurism removal.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2012
This paper presents the analysis of the autonomic nervous system (ANS) control and cardiac baroreflex sensitivity in patients undergoing general anesthesia for major surgery, with the goal of evaluating the effects of anesthesia bolus induction with propofol on autonomic control of heart rate (HR) and arterial blood pressure (ABP). The increase in baroreflex gain in the LF band observed through two different methods hints at the fact that the baroreflex may increase heart period (HP) following a transient ABP decrease, but its response displays a larger amplitude, to compensate for the blunting of the sympathetic action on heart rate and vascular resistance.
View Article and Find Full Text PDF