Objectives: Carotid plaque vulnerability is a strong predictor of recurrent ipsilateral stroke, but differentiation of plaque components using conventional computed tomography (CT) is suboptimal. The aim of our study was to evaluate the ability of dual-energy CT (DECT) to characterize atherosclerotic carotid plaque components based on the effective atomic number and effective electron density using magnetic resonance imaging (MRI) and, where possible, histology as the reference standard.
Materials And Methods: Patients with recent cerebral ischemia and a ≥2-mm carotid plaque underwent computed tomography angiography and MRI.
Objectives: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CT-imaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition.
Materials And Methods: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin.
Multienergy cardiovascular computed tomography (CT) imaging can be defined as data acquisition at two (dual-energy) or multiple x-ray energies. Multienergy cardiovascular CT imaging provides additional qualitative and quantitative information such as material maps or virtual monoenergetic images, which are supposed to further improve the quality and diagnostic yield of CT. Recently introduced photon-counting detector CT scanners further address some of the challenges and limitations of previous, conventional CT machines, hereby enhancing and extending the applications of CT for cardiovascular imaging.
View Article and Find Full Text PDFBackground: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has been increasingly utilized as a life-saving modality in patients with cardiopulmonary compromise. Acute limb ischemia (ALI) has been reported when the femoral artery was accessed, and it was associated with higher mortality in patients on extracorporeal membrane oxygenation (ECMO). However, prior studies were limited by small sample size and the lack of long-term follow-up.
View Article and Find Full Text PDFObjectives: The aim of this study was to evaluate the feasibility and efficacy of chronic pulmonary thromboembolism assessment using photon-counting detector computed tomography (PCD-CT) iodine maps of the lung parenchyma.
Materials And Methods: This institutional review board-approved retrospective study included 83 subjects (49.4% male, aged 62.
Background: The patency of intracranial stents may not be reliably assessed with either CT angiography or MR angiography due to imaging artifacts. We investigated the potential of ultra-high resolution CT angiography using a photon counting detector (PCD) CT to address this limitation by optimizing scanning and reconstruction parameters.
Methods: A phantom with different flow diverters was used to optimize PCD-CT reconstruction parameters, followed by imaging of 14 patients with intracranial stents using PCD-CT.
Objectives: To investigate the influence of kernels and iterative reconstructions on pericoronary adipose tissue (PCAT) attenuation in coronary CT angiography (CCTA).
Materials And Methods: Twenty otherwise healthy subjects (16 females; median age 52 years) with atypical chest pain, low risk of coronary artery disease (CAD), and without CAD in photon-counting detector CCTA were included. Images were reconstructed with a quantitative smooth (Qr36) and three vascular kernels of increasing sharpness levels (Bv36, Bv44, Bv56).
Pericoronary adipose tissue (PCAT) attenuation and the fat attenuation index (FAI) may serve as markers of inflammation and the risk of adverse cardiac events. However, standardization of relevant CT acquisition and reconstruction parameters is lacking. The purpose of this study was to investigate the influence of vessel attenuation, the virtual monoenergetic image (VMI) level, and the reconstruction kernel on PCAT attenuation and FAI by use of energy-integrating detector (EID) and photon-counting detector (PCD) CT systems in an ex vivo porcine heart model.
View Article and Find Full Text PDFObjectives: This study aims to demonstrate reduced iodine contrast media (CM) in routine abdominal CT scans in portal venous phase (PVP) using a photon-counting detector CT (PCD-CT) compared to total body weight (TBW) and kV-adapted CM injection protocols on a state-of-the-art energy-integrating detector CT (EID-CT) while maintaining sufficient image quality (IQ).
Materials And Methods: Consecutive contrast-enhanced abdominal PVP CT scans from an EID-CT (Nov 2022-March 2024) and a PCD-CT (Sep 2023-Dec 2023) were compared. CM parameters (total iodine load (TIL), iodine delivery rate (IDR) and dosing factor (DF)) were reported.
Purpose: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT).
Methods: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.
Purpose: To determine the value of an algorithm for reducing stair-step artifacts for advanced coronary analyses in sequential mode coronary CT angiography (CCTA).
Methods: Forty patients undergoing sequential mode photon-counting detector CCTA with at least one stair-step artifact were included. Twenty patients (14 males; mean age 57±17years) with 45 segments showing stair-step artifacts and without atherosclerosis were included for CT analysis.
Objective: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization.
View Article and Find Full Text PDFIntroduction: The pain associated with lower extremity arterial disease is difficult to treat, even with lower extremity revascularization. We sought to evaluate in-hospital and post-operative opioid usage in patients with different disease severities and treatments for lower extremity vascular disease.
Methods: A retrospective review was performed for all hospital encounters for patients with an International Classification of Diseases (ICD) code consistent with lower extremity arterial disease admitted to a single center between January 2018 and March 2023.
Purpose: To compare the diagnostic approach of acute pulmonary embolism (PE) with photon-counting-detector CT (PCD-CT) and energy-integrating-detector CT (EID-CT).
Materials And Methods: Two cohorts underwent CT angiographic examinations with EID-CT (Group 1; n = 158) and PCD-CT (Group 2; n = 172), (b) with two options in Group 1, dual energy (Group 1a) or single energy (Group 1b) and a single option in Group 2 (spectral imaging with single source).
Results: In Group 2, all patients benefited from spectral imaging, only accessible to 105 patients (66.
Objectives: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels.
View Article and Find Full Text PDFObjective: With an aging patient population, an increasing number of octogenarians are undergoing elective endovascular abdominal aortic aneurysm repair (EVAR) in the United States. Multiple studies have shown that, for the general population, use of local anesthetic (LA) for EVAR is associated with improved short-term and long-term outcomes as compared with performing these operations under general anesthesia (GA). Therefore, this study aimed to study the association of LA for elective EVARs with perioperative outcomes, among octogenarians.
View Article and Find Full Text PDFCT of the heart, in particular ECG-controlled coronary CT angiography (cCTA), has become clinical routine due to rapid technical progress with ever new generations of CT equipment. Recently, CT scanners with photon-counting detectors (PCD) have been introduced which have the potential to address some of the remaining challenges for cardiac CT, such as limited spatial resolution and lack of high-quality spectral data. In this review article, we briefly discuss the technical principles of photon-counting detector CT, and we give an overview on how the improved spatial resolution of photon-counting detector CT and the routine availability of spectral data can benefit cardiac applications.
View Article and Find Full Text PDFPurpose: Advantages of virtual monoenergetic images (VMI) have been reported for dual energy CT of the head and neck, and more recently VMIs derived from photon-counting (PCCT) angiography of the head and neck. We report image quality metrics of VMI in a PCCT angiography dataset, expanding the anatomical regions evaluated and extending observer-based qualitative methods further than previously reported.
Methods: In a prospective study, asymptomatic subjects underwent contrast enhanced PCCT of the head and neck using an investigational scanner.
Topic Importance: Thoracic imaging with CT scan has become an essential component in the evaluation of respiratory and thoracic diseases. Providers have historically used conventional single-energy CT; however, prevalence of dual-energy CT (DECT) is increasing, and as such, it is important for thoracic physicians to recognize the utility and limitations of this technology.
Review Findings: The technical aspects of DECT are presented, and practical approaches to using DECT are provided.
Purpose: Imaging stents and in-stent stenosis remains a challenge in coronary computed tomography angiography (CCTA). In comparison to conventional Computed Tomography, Photon Counting CT (PCCT) provides decisive clinical advantages, among other things by providing low dose ultra-high resolution imaging of coronary arteries. This work investigates the image quality in CCTA using clinically established kernels and those optimized for the imaging of cardiac stents in PCCT, both for in-vitro stent imaging in 400 μm standard resolution mode (SRM) and 200 μm Ultra High Resolution Mode (UHR).
View Article and Find Full Text PDFPurpose: The aim of this study was to assess the effect of temporal resolution on subjective and objective image quality of coronary computed tomography angiography (CCTA) in the ultra-high-resolution (UHR) mode with dual-source photon-counting detector (PCD) CT.
Materials And Methods: This retrospective, institutional review board-approved study evaluated 30 patients (9 women; mean age, 80 ± 10 years) undergoing UHR CCTA with a clinical dual-source PCD-CT scanner. Images were acquired with a tube voltage of 120 kV and using a collimation of 120 × 0.
Background: We investigated about optimization of contrast media (CM) dose or radiation dose in thoracoabdominal computed tomography angiography (CTA) by automated tube voltage selection (ATVS) system configuration and CM protocol adaption.
Methods: In six minipigs, CTA-optimized protocols were evaluated regarding objective (contrast-to-noise ratio, CNR) and subjective (6 criteria assessed by Likert scale) image quality. Scan parameters were automatically adapted by the ATVS system operating at 90-kV semi-mode and configured for standard, CM saving, or radiation dose saving (image task, quality settings).
Novel photon-counting detector CT (PCD-CT) has the potential to address the limitations of previous CT systems, such as insufficient spatial resolution, limited accuracy in detecting small low-contrast structures, or missing routine availability of spectral information. In this review article, we explain the basic principles and potential clinical benefits of PCD-CT, with a focus on recent literature that has grown rapidly since the commercial introduction of a clinically approved PCD-CT.
View Article and Find Full Text PDFThe biogenesis of mitoribosomes is an intricate process that relies on the coordinated synthesis of nuclear-encoded mitoribosomal proteins (MRPs) in the cytosol, their translocation across mitochondrial membranes, the transcription of rRNA molecules in the matrix as well as the assembly of the roughly 80 different constituents of the mitoribosome. Numerous chaperones, translocases, processing peptidases, and assembly factors of the cytosol and in mitochondria support this complex reaction. The budding yeast Saccharomyces cerevisiae served as a powerful model organism to unravel the different steps by which MRPs are imported into mitochondria, fold into their native structures, and assemble into functional ribosomes.
View Article and Find Full Text PDF