Publications by authors named "Flavio Neves"

This study aimed to evaluate the scanning time and marginal fit of CAD/CAM crowns fabricated using different intraoral scanning systems (IOS) (O1-Omnicam 1.0, O2-Omnicam 2.0, PS-Primescan).

View Article and Find Full Text PDF

The purpose of this study was to evaluate the impact of various mechanical surface treatments on the surface roughness and microtensile bond strength (µTBS) of aged composite resin cores bonded to CAD/CAM restorations. Composite resin specimens (Filtek Z350 XT, 3M-ESPE/Solventum) were thermally aged and subsequently divided into four groups (n = 36) according to surface treatments: UI-cleaning with ultrasonic diamond tip; AO-sandblasting with 50 µm AlO; DB-cleaning with diamond burs; and CG-positive control group, without aging or surface treatment. Surface roughness was assessed using a profilometer and interferometer, with measurements taken on both sides of each specimen (n = 12).

View Article and Find Full Text PDF

Computer-aided manufacturing (CAM) technology allows the use of different manufacturing techniques. This in vitro study aimed to evaluate the marginal fit of temporary restorations manufactured using conventional chairside methods, milling, and three-dimensional printing. Fifteen 3-element temporary restorations specimens were produced and categorized into three groups: non-digital, obtained using the conventional chairside method (GC); milled (GM); and three-dimensionally printed (GP).

View Article and Find Full Text PDF

Purpose: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers.

Materials And Methods: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner.

View Article and Find Full Text PDF

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations.

View Article and Find Full Text PDF

Objectives: This in vitro comparative study aimed to evaluate the physical and mechanical properties of four 3D-printed resins with two different thickness layers.

Methods: Four printed resins (VarseoSmile Crown Plus, VSC; NexDent C&B MFH, MFH; Nanolab 3D, NNL; and Resilab 3D Temp, RSL) were printed with 50 µm and 100 µm layer thickness, resulting in 80 bars measuring 25 × 2×2 mm. The specimens underwent a Raman spectroscopy for degree of conversion, confocal laser scanning microscopy for surface roughness (Sa), three-point bending test for flexural strength and elastic modulus, and a Vickers hardness test (VHN).

View Article and Find Full Text PDF

In the last few decades, there have been considerable improvements in the diagnosis and care of Duchenne muscular dystrophy (DMD), the most common childhood muscular dystrophy. International guidelines have been published and recently reviewed. A group of Brazilian experts has developed a standard of care based on a literature review with evidence-based graded recommendations in a two-part publication.

View Article and Find Full Text PDF

In this work, we present 5 cases of Kennedy Class I patients with atrophic posterior mandible treated with the placement of 01 short WS Neodent® implant and a healing screw to support the removable prosthesis, transforming them into Kennedy Class III patients. To quickly evaluate and verify the benefit of this treatment, masticatory performance was evaluated with maximum bite force and chewing ability. A VAS questionnaire was also applied for a practical preoperative and postoperative evaluation of overall quality of life-changing for the patient after this treatment.

View Article and Find Full Text PDF

The aim of this study was to evaluate the influence of the geometry of the screwdriver-screw connection on the reverse torque of UCLA screws after repeated cycles of tightening and loosening in an implant-supported prosthesis. Thirty sets of external hex titanium implants, UCLA abutments, and UCLA abutment screws were divided into 3 experimental groups (n = 10). In the square group, the implant and UCLA abutment system were mounted in an upright position using a screw with a square screwdriver-screw connection.

View Article and Find Full Text PDF

Objective: To evaluate the effect of exposure time and moving the light-curing unit (LCU) on the degree of conversion (DC) and Knoop microhardness (KH) of two resin cements that were light-cured through ceramic.

Methods: Two resin cements: AllCem Veneer APS (FGM) and Variolink Esthetic LC (Ivoclar Vivadent) were placed into a 0.3 mm thick matrix in 6 locations representing the canine to canine.

View Article and Find Full Text PDF

Statement Of Problem: Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear.

Purpose: The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs.

View Article and Find Full Text PDF

The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test.

View Article and Find Full Text PDF

This paper presents an omnidirectional RGB-D (RGB + Distance fusion) sensor prototype using an actuated LIDAR (Light Detection and Ranging) and an RGB camera. Besides the sensor, a novel mapping strategy is developed considering sensor scanning characteristics. The sensor can gather RGB and 3D data from any direction by toppling in 90 degrees a laser scan sensor and rotating it about its central axis.

View Article and Find Full Text PDF

Statement Of Problem: Narrow implants have limited indications, and implant fracture may occur when these indications are not followed.

Purpose: The purpose of this in vitro study was to investigate the mechanical behavior of a 2.9-mm-diameter implant using a fatigue limit test and to investigate the Morse effect of 2 different Morse taper systems, 2.

View Article and Find Full Text PDF

Wire-mesh sensors are used to determine the phase fraction of gas⁻liquid two-phase flow in many industrial applications. In this paper, we report the use of the sensor to study the flow behavior inside an offshore oil and gas industry device for subsea phase separation. The study focused on the behavior of gas⁻liquid slug flow inside a flow distribution device with four outlets, which is part of the subsea phase separator system.

View Article and Find Full Text PDF

Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge.

View Article and Find Full Text PDF

Significant advances in the understanding and management of Duchenne muscular dystrophy (DMD) have occurred since the publication of international guidelines for DMD care in 2010. Our objective was to provide an evidence-based national consensus statement for multidisciplinary care of DMD in Brazil. A combination of the Delphi technique with a systematic review of studies from 2010 to 2016 was employed to classify evidence levels and grade of recommendations for the guideline.

View Article and Find Full Text PDF

Statement Of Problem: The manufacturers of computer-aided design and computer-aided manufacturing (CAD-CAM) systems emphasize that new technologies can improve the marginal fit of dental crowns. However, data supporting this claim are limited.

Purpose: The purpose of this in vitro study was to investigate the differences among the following fabrication methods on the marginal discrepancy of dental crowns: intraoral optical scanners, powder application, and adjustments of intaglio surface.

View Article and Find Full Text PDF

Purpose: This study evaluated the microleakage at different implant-abutment (I-A) connections under unloaded and loaded conditions.

Materials And Methods: Forty implants, specially designed with an opening at the apex, were grouped according to the I-A and screw device: external hexagon implants with titanium (EH) or EH diamond-like carbon screws fixing the abutment; internal hexagon implants with titanium screws (IH); and Morse taper implants with solid (MT) or MT passing screws (MTps) abutments. The implants were fixed in a 2-compartment device, and toluidine blue solution (1.

View Article and Find Full Text PDF

The aim of this study was to evaluate the influence of abutments with a prosthetic index on the fracture resistance of Morse taper dental implants. Morse taper implants were divided into 2 groups (n = 5 per group): a group with an indexed implant and a nonindexed abutment (solid Morse taper universal post; WIS group), and a group with an indexed implant and an indexed abutment (WIP group). Both groups were subjected to bending tests for fracture strength until 5 mm of displacement or implant fracture occurred.

View Article and Find Full Text PDF

The aim of this study is to evaluate the effects of replacing poorly fitting dentures on patient's masticatory function, satisfaction and oral health-related quality of life. Fourteen patients with conventional maxillary complete dentures and mandibular overdentures retained by two implants bar clip system had their dentures replaced. The laboratory tests for the analysis of masticatory performance were conducted using an "Optocal" food simulator test.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the effectiveness of fabrication methods (computer-aided design/computer-aided manufacture [CAD/CAM], copy-milling, and conventional casting) in the fit accuracy of three-unit, screw-retained fixed dental prostheses.

Materials And Methods: Sixteen three-unit implant-supported screw-retained frameworks were fabricated to fit an in vitro model. Eight frameworks were fabricated using the CAD/CAM system, four in zirconia and four in cobalt-chromium.

View Article and Find Full Text PDF

In this paper the extended autocorrelation velocity estimator is evaluated and compared using a nondestructive ultrasonic device. For this purpose, three velocity estimators are evaluated and compared. The autocorrelation method (ACM) is the most used and well established in current ultrasonic velocity profiler technology, however, the technique suffers with phase aliasing (also known as the Nyquist limit) at higher velocities.

View Article and Find Full Text PDF

This study sought to assess the effect of different surface finishing and polishing protocols on the surface roughness and bacterial adhesion (S. sanguinis) to polymethyl methacrylates (PMMA). Fifty specimens were divided into 5 groups (n = 10) according to their fabrication method and surface finishing protocol: LP (3 : 1 ratio and laboratory polishing), NF (Nealon technique and finishing), NP (Nealon technique and manual polishing), MF (3 : 1 ratio and manual finishing), and MP (3 : 1 ratio and manual polishing).

View Article and Find Full Text PDF

Objectives: To evaluate clinical, radiographic, microbiologic, and biomechanical parameters related to bone remodeling around implants with external hexagon (EH) and Morse-taper (MT) connections.

Materials And Methods: Twelve totally edentulous patients received four custom-made implants in the interforaminal region of the mandible. Two of those implants had the same macroscopic design, but different prosthetic connections.

View Article and Find Full Text PDF