Purpose: To evaluate color change in ceramic veneers luted to enamel with light-cured, dual-cured resin luting agents, or heated resin composites, as well as to evaluate microhardness and diametral tensile strength of these luting agents.
Methods: For color analysis, 0.5 mm-thick leucite-reinforced glass ceramic veneers (IPS Empress CAD) were cemented onto 40 bovine dental blocks (n= 10) using RelyX Ultimate (RU) or RelyX Veneer (RV) resin-based luting agents, or Gradia Direct (GD) and Palfique Lx5 (P) heated resin composites.
Diseases of the paranasal sinuses, nasal cavities, and those related to the skull base can be treated with nasal endoscopic surgery. Anatomical references are essential to safely perform these surgeries. To measure and compare the distance from the posterior wall of the maxillary sinus to the anterior skull base in cadavers and on computed tomography (CT) scans to determine a measurement as an anatomical reference in imaging exams for sinus and anterior skull base surgery.
View Article and Find Full Text PDFUnlabelled: Glass ceramics are widely used to manufacture esthetic veneers, inlays, onlays, and crowns. Although the clinical survival rates ofglass-ceramic restorations arefavorable,fractures or chips are common. Certain cases can be repaired with direct composite.
View Article and Find Full Text PDFBackground: There is no updated national data regarding the real impact of the COVID-19 pandemic on delaying diagnosis and treatment among patients with lung, and head, and neck cancers in Brazil. This study aimed to analyze the COVID-19 pandemic impact on cancer diagnosis and clinical outcomes among lung, head, and neck cancer patients assisted in a tertiary cancer center in Southeastern Brazil, as well as to analyze these patients' pretreatment clinical features.
Methods: Retrospective cohort of patients with lung or head and neck cancer assisted in a tertiary cancer center in southeastern Brazil between January/2019 and December/2021.
Unlabelled: During the manufacture of ceramic restorations there is an important step of finishing and polishing and the effects of different types of these procedures on the surface characteristics of ceramics are not known for sure.
Aim: To evaluate the effects of various surface treatments and immersion in coloring substances on the roughness, microhardness, and color stability of CAD-CAM monolithic ceramics.
Materials And Method: The ceramics used were lithium disilicate reinforced with zirconium dioxide (Suprinity), lithium disilicate (E.
Purpose: To evaluate over time the bond strength to dentin of different resin composites (RBCs) associated with the universal adhesive system applied with self-etching or total-etching strategies.
Methods: 60 human third molars were obtained, randomly divided into experimental groups (n= 10) according to RBCs: methacrylate-based nanofilled (Z350 XT); low-viscosity Ormocer-based bulk-fill (Admira Fusion X-base Universal); or high-viscosity Ormocer-based bulk-fill composite (Admira Fusion X-tra). The adhesion procedure was performed using a universal adhesive (Futurabond U) applied in self-etching or total-etching mode.
Purpose: To evaluate the effect of different varnishes on dentin permeability to erosive/abrasive challenges.
Methods: 60 superficial dentin discs were randomly allocated to six groups (n=10): Duraphat, PRG Barrier Coat, Clinpro XT, Profluorid, Fluor Protector S and untreated (control). Permeability tests were carried out: after acid conditioning, after treatment, and after abrasive/erosive challenges.
J Mech Behav Biomed Mater
August 2023
Aims: To evaluate the influence of the type of preparation and mechanical cycling on the fracture load and failure mode of semi-direct posterior resin composite restorations.
Methods: In total, 70 healthy third molars were used; 10 belonging to the control group (C - unprepared teeth) and 60 teeth prepared and restored with nanoparticle resin composite, divided into 3 groups (n = 20): O - exclusively occlusal preparation (Table Top); OV - occlusal preparation with buccal extension (Veneerlay); OVP - Occlusal preparation with chamfer on the proximal and buccal-lingual/palatal surfaces (Overlay). The preparations were performed with diamond burs with a thickness of 1 mm.
Unlabelled: After ozone therapy for bleaching, it is important to evaluate enamel surface properties, to ensure that bleaching provides adequate conditions for sound dental substrate. Aim: The aim of this in vitro study was to evaluate the effects of a bleaching treatment with 10% carbamide peroxide (CP), with or without ozone (O), on the microhardness, roughness and micromorphology of the enamel surface.
Materials And Method: Bovine enamel blocks were planed and distributed among the following three bleaching treatment groups (n=10): CP - 1 hour per day/14 days (Opalescence PF 10%/ Ultradent); O - 1 hour per day every 3 days/3 sessions (Medplus V Philozon, 60 mcg/mL and oxygen flow rate of 1 L/min); and OCP - CP with O, 1 hour per day every 3 days/3 sessions.
This study aimed to evaluate the effect of endodontic sealer (ES) on bond strength (BS) of prefabricated or milled-CAD-CAM (computer-aided design and computer-aided manufacturing) glass-fiber-posts (GFP). Canals of 90 single-rooted teeth were prepared for filling by the single-cone technique with gutta-percha and one of the following ES: AH Plus (epoxy resin), Endofill (zinc-oxide and eugenol), and Bio-C Sealer (calcium-silicate). After post-space preparation, tooth-specimens were equally divided in half according to type of GFP to be used.
View Article and Find Full Text PDFAim: This study evaluated the influence of chitosan added to a universal adhesive system used in totaletch (TE) or self-etch (SE) mode on dentin permeability, and on the micromorphology of the adhesive layer.
Materials And Method: Dentin discs were obtained from human third molars and randomly distributed according to bonding strategy (TE or SE), and to whether or not 1% chitosan (C) was added to a universal adhesive system (Single Bond Universal/3M ESPE), to create the following groups (n=10): TE, TEC, SE, and SEC. Dentin permeability was measured at baseline and after application of dentin treatments.
Photodiagnosis Photodyn Ther
March 2023
Background: The purpose of this study was: 1) to analyze the physical-chemical properties of hydrogen peroxide (HP) agents at 7.5% (HP7) and 35% (HP35), and the association with or without TiO nanotubes; 2) to evaluate dental bleaching effectiveness by using HP7 and HP35 together with or without TiO nanotubes, and applied with or without violet LED (VL).
Methodology: 80 bovine incisors were treated according to groups (n = 10): HP35; HP35 + VL; HP35T (HP35 + TiO); HP35T + VL; HP7; HP7 + VL; HP7T (HP7 + TiO); HP7T + VL.
Background And Purpose: Neutrophil overstimulation plays a crucial role in tissue damage during severe infections. Because pathogen-derived neuraminidase (NEU) stimulates neutrophils, we investigated whether host NEU can be targeted to regulate the neutrophil dysregulation observed in severe infections.
Experimental Approach: The effects of NEU inhibitors on lipopolysaccharide (LPS)-stimulated neutrophils from healthy donors or COVID-19 patients were determined by evaluating the shedding of surface sialic acids, cell activation, and reactive oxygen species (ROS) production.
Clin Oral Investig
April 2023
Objectives: The effects of different concentrations of titanium dioxide (TiO) into 40% hydrogen peroxide (HP) were evaluated as regards the effectiveness of dental color change either associated with activation by polywave LED light or not.
Materials And Methods: TiO (0, 1, 5, or 10%) was incorporated into HP to be applied during in-office bleaching (3 sessions/40 min each). Polywave LED light (Valo Corded/Ultradent) was applied or not in activation cycles of 15 s (total time of 2 min).
Exp Parasitol
December 2022
Arthropod-borne viral diseases are important public health threats in tropical countries. In the Americas, diseases such as Dengue, Zika, Chikungunya, Mayaro, and Yellow fever, which are mainly transmitted by Aedes aegypti L. are responsible for high rates of morbidity and mortality in the populations.
View Article and Find Full Text PDFAcidic conditions can cause hydrolysis and accelerate degradation of resin composites (RCs). Since there are limited and controversial data on the effect of acids on bulk-fill RCs, this study assessed the surface roughness (SR) and flexural strength (FS) of these RCs under simulated carious and erosion conditions. Bars of Filtek Bulk Fill (FBF, 3M/ESPE), X-tra fil (XTF, Voco), Tetric N-Ceram Bulk Fill (TBF, Ivoclar/Vivadent), and Aura Bulk Fill (ABF, SDI) and a conventional RC [Filtek Z350XT (FZ, 3M/ESPE)] were allocated (n=15) to undergo caries or erosion conditions.
View Article and Find Full Text PDFMaterials (Basel)
August 2022
This study aimed to evaluate the influence of thermomechanical cycling (TMC) and type of abutment on the misfit and compressive strength of the implant−abutment interface. Forty 3.75-mm external hexagon implants with 25° angled abutments were divided into four groups (N = 10).
View Article and Find Full Text PDFIntroduction: Head and neck cancer is considered one of the most common types, and its treatment includes radiotherapy, which can trigger side effects and undesirable sequelae in the oral cavity and dental tissues.
Objective: This study aimed to make an in vitro evaluation of the shear strength and failure mode of ceramic orthodontic brackets bonded with two different composites in enamel submitted to ionizing radiation.
Methods: After the study was approved by the Research Ethics Committee, 60 healthy human premolars were selected and divided into two groups, based on the absence or presence of ionizing irradiation of the enamel.
Am J Dent
February 2022
Purpose: To evaluate the effect of polishing systems (discs or rubbers) on surface roughness (Ra) and color change (ΔE) of two bulk fill and one conventional resin composite after immersion in a dye solution.
Methods: 180 samples (10 mm x 2 mm) were separated into three groups: (1) Resin composite: Filtek One Bulk Fill (FO), Tetric N-Ceram Bulk Fill (TNC), Filtek Z350 XT (FXT) (n= 60); (2) polishing system: unpolished (control); aluminum oxide discs (Sof-Lex, AOD); cup-shaped abrasive rubber polishers (Astropol, CSA) (n= 20), and (3) immersion solutions: coffee or distilled water (n= 10). Immersion was under 5 mL of each solution for 3 hours daily, for 30 days.
J Adhes Dent
March 2022
Purpose: To evaluate the influence of dimethyl sulfoxide (DMSO) solutions used as dentin pretreatments on microtensile bond strength (µTBS), as well as the dentin/restoration interface micromorphology of a universal adhesive in etch-and-rinse or self-etch mode.
Materials And Methods: Eighty blocks of dentin were submitted to acid conditioning with 35% phosphoric acid (etch-and-rinse), or not (self-etch), and distributed among the treatments (n = 10): CON: Scotchbond Universal/3M Oral Care; DMSO: pretreatment with DMSO; DMSO/water: pretreatment with DMSO in water (1:1); DMSO/ethanol: pretreatment with DMSO in ethanol (1:1). Microtensile bond strength and failure tests were performed after 24-h and 6-month storage.
Int J Esthet Dent
February 2022
Background: Due to controversial results in relation to the influence of desensitizing agents on sensitivity during bleaching, the present study evaluated the degree of tooth bleaching sensitivity, color change, and patient acceptability of desensitizing agents containing potassium nitrate/sodium fluoride (PNF) or nanostructured calcium phosphate (N) associated with in-office bleaching with 35% hydrogen peroxide (HP).
Materials And Methods: Seventy-five patients were randomly distributed into three groups (n = 25): 1) Group W - in-office bleaching (Whiteness HP Maxx - three sessions of 45 min); 2) Group WD - associated with PNF desensitizing gel (Desensibilize KF 2%) applied for 10 min before each session; 3) Group WDN - associated with N desensitizing paste (Desensibilize Nano P) applied after bleaching for 5 min. The degree of sensitivity and patient acceptability of the desensitizing treatments were evaluated using a visual analog scale.
Purpose: To evaluate the color, surface roughness and microhardness of human dental enamel subjected to brushing with whitening dentifrices.
Methods: The enamel samples (4 x 4 x 2 mm) were darkened using 0.2% chlorhexidine and black tea, and were randomly divided into seven groups (n= 15) for brushing cycles with only water; control; conventional dentifrice (Colgate Maximum Anticaries Protection); dentifrice containing 2% hydrogen peroxide (Colgate Luminous White Advanced); dentifrice containing sodium tripolyphosphate (Sensodyne True White); dentifrice containing activated charcoal (Black is White); and dentifrice containing blue covarine (Close Up White Now).
Several mechanical and biological factors may change the orthodontic wire frictional resistance (FR). Titanium dioxide (TiO ) and silica dioxide (SiO ) nanoparticle (NP) coatings may be used to improve the characteristics of materials, reducing FR between archwire and bracket. This in vitro study aimed to evaluate the FR of orthodontic wires with and without coating in both dry and wet environments and measure the surface roughness (SR).
View Article and Find Full Text PDFBackground: To evaluate the microshear bond strength (μ-SBS) between resin-based cements and core build-up materials after water storage.
Material And Methods: Cylinders (1x1 mm) of conventional dual-cure resin cement (RelyX ARC, 3M ESPE), universal dual-cure resin cement (RelyX Ultimate, 3M ESPE) or self-adhesive resin cement (RelyX U200, 3M ESPE) were adhered to disks (6x2 mm) made with commercial core build-up materials (Bis-Core, Bisco or LuxaCore Z, DMG) or conventional nanocomposite resin (Filtek Z350 XT, 3M ESPE). The specimens (n=10) were submitted to μ-SBS test using a universal testing machine and fracture pattern analysis at 48 hours or after 9 months of water storage.
The aim of this study was to compare low- and high-viscosity bulk-fill composites for Knoop microhardness (KHN), microtensile bond strength (MTBS) to dentin in occlusal cavities, and fracture strength (FS) in molars with mesialocclusal- distal restoration. Disk-shaped samples with different thicknesses (2 or 4 mm) of low-viscosity (SDR Flow, Dentsply) and high-viscosity bulk-fill composites (Filtek BulkFill, 3M ESPE; and Tetric-N Ceram Bulk Fill, Ivoclar Vivadent) were prepared for top and bottom KHN analysis (n=10). MTBS to dentin and fracture pattern was evaluated in human molars with occlusal cavities restored with (n=10): conventional nanocomposite (Z350XT, 3M ESPE), low-viscosity (Filtek Bulk-fill Flow, 3M ESPE) or high-viscosity bulk-fill composites (Filtek BulkFill).
View Article and Find Full Text PDF