The erythrocyte sedimentation rate (ESR) is a widely used diagnostic test, influenced by all physiological and pathological conditions that can bias blood rheology by interfering factors. This study aimed to evaluate the performance of the CUBE 30 touch ESR analyzer in samples with preanalytical variables, as lipemia, hemolysis, and icterus or in presence of fibrinogen., Moreover we focused to define the maximum time limits to ensure a reliable ESR measure.
View Article and Find Full Text PDFBackground: Erythrocyte Sedimentation Rate (ESR) is an easy test used to diagnose and monitor inflammatory and infectious diseases. The aim of this study was the evaluation of the performance of three ESR automated analyzers, VES-MATIC 5, CUBE 30 TOUCH, and MINI-CUBE, involving four Italian polyclinics in Rome, Siena, Como, and Arezzo, as well as inter-site variability assessment to detect possible device-dependent and operator-dependent influences.
Methods: Accuracy analysis was carried out by analyzing the same samples with all three instruments and comparing them with the Westergren method.
(1) Background: Hepatitis C virus (HCV) screening mostly uses a one-assay anti-HCV testing approach, which has a higher probability of false-positive results in populations with low HCV prevalence. (2) Methods: In this investigation, 17,926 participants were screened for HCV, and the reactives were tested using a two-assay anti-HCV approach: Elecsys ElectroChemiLuminescence (ECL) and a ChemiLuminescence ImmunoAssay (CLIA), respectively. A recombinant immunoblot assay (RIBA) was performed to confirm anti-HCV positivity.
View Article and Find Full Text PDF(1) Background: The erythrocyte sedimentation rate (ESR) is widely diffused in hematology laboratories to monitor inflammatory statuses, response to therapies (such as antibiotics), and oncologic diseases. However, ESR is not a specific diagnostic marker but needs to be contextualized and compared with clinical and other laboratory findings. This study aimed to investigate the performance of two automated instruments, namely the DIESSE CUBE 30 TOUCH (DIESSE, Siena, Italy) and the Alifax Test 1 (Alifax Srl, Polverara, Italy), in comparison with the gold standard, the Westergren method, in lymphoproliferative and myeloproliferative patients.
View Article and Find Full Text PDFBackground: Erythrocyte sedimentation rate (ESR) indirectly measures blood fibrinogen, and it is altered by all those pathological conditions that modify the aggregation of red blood cells. The international guidelines by the International Council for Standardization in Hematology (ICSH) define the Westergren method as the gold standard for ESR, although it is completely operator-dependent, time-consuming, and requires a patient's blood consumption. Therefore, the validation of new ESR analyzers is needed.
View Article and Find Full Text PDFThe use of vaccines has allowed the containment of coronavirus disease 2019 (COVID-19) at a global level. The present work aims to add data on vaccination by evaluating the level of neutralizing antibodies in individuals who have received a three-vaccination series. For this purpose, we ran a surveillance program directed at measuring the level of IgG Abs against the Receptor Binding Domain (RBD) and surrogate virus neutralizing Ab (sVNT) anti-SARS-CoV-2 in the serum of individuals undergoing vaccination.
View Article and Find Full Text PDFSaliva is a very complex fluid and it is essential to maintain several physiological processes and functions, including oral health, taste, digestion and immunological defenses. Saliva composition and the oral microbiome can be influenced by several factors, like diet and smoking habits, and their alteration can represent an important access point for pathogens and, thus, for systemic illness onset. In this review, we explore the potentiality of saliva as a new tool for the early detection of some pathological conditions, such as oral diseases, chronic degenerative non-communicable diseases, among these chronic kidney disease (CKD).
View Article and Find Full Text PDFThe World Health Organization has recently identified three categories of pathogens, namely: critical, high, and medium priority, according to the need for new antibiotics. Critical priority pathogens include carbapenem-resistant microorganism (CPO) such as and , , and spp., whereas vancomycin-resistant (VRE) methicillin and vancomycin-resistant (MRSA) are in the high priority list.
View Article and Find Full Text PDFInt J Environ Res Public Health
November 2022
(1) Background: A clinical laboratory index to assess gut dysbiosis is the F/B ratio < 0.8. In fact, an elevated proportion of Firmicutes and a reduced population of Bacteroides in diabetes type 2 (T2D) subjects has been observed.
View Article and Find Full Text PDFBackground: SARS-CoV-2 T-cells are crucial for long-term protection against reinfection. The aim was to demonstrate the Interferon-gamma Release Assay (IGRA) test could be useful for vaccination monitoring. Methods: In a prospective cohort of 98 vaccinated healthcare workers for SARS-CoV-2, we selected 23 people in low-antibodies (Group 1, N = 8), high-antibodies (Group 2, N = 9), and negative control groups (Group 3, N = 6).
View Article and Find Full Text PDF(1) Background: The production of anti-SARS-CoV-2 antibodies should help minimize the severity of COVID-19 disease. Our focus was to investigate and compare different vaccination schedules, monitoring circulating S-RBD Ab (antibodies anti-Spike protein-Receptor Binding Domain) levels after administering two doses in naïve patients. Likewise, vaccine-stimulated immunity in naïve and previously infected patients was compared.
View Article and Find Full Text PDFWith the widespread use of coronavirus disease 2019 (COVID-19) vaccines, a rapid and reliable method to detect SARS-CoV-2 neutralizing antibodies (NAbs) is extremely important for monitoring vaccine effectiveness and immunity in the population. The purpose of this study was to evaluate the performance of the RapiRead™ reader and the TestNOW™ COVID-19 NAb rapid point-of-care (POC) test for quantitative measurement of antibodies against the spike protein receptor-binding domain of severe respiratory syndrome coronavirus 2 (SARS-CoV-2) in different biological matrices compared to chemiluminescence immunoassay (CLIA) methods. Ninety-four samples were collected and analyzed using a RapiRead™ reader and TestNOW™ COVID-19 NAb kits for detecting neutralizing antibodies, and then using two CLIAs.
View Article and Find Full Text PDFBackground: Several commercial surrogate Virus Neutralization Tests (sVNTs) have been developed in the last year. Neutralizing anti-SARS-CoV-2 antibodies through interaction with Spike protein Receptor Binding Domain (S-RBD) can block the virus from entering and infecting host cells. However, there is a lack of information about the functional activity of SARS-CoV-2 antibodies that may be associated with protective responses.
View Article and Find Full Text PDFClin Immunol
January 2022
The Spike-Receptor Binding Domain (S-RBD) is considered the most antigenic protein in SARS-CoV-2 and probably the key player in SARS-CoV-2 immune response. Quantitative immunoassays may help establish an anti-RBD Abs threshold as an indication of protective immunity. Since different immunoassays are commercial, the standard reference method for the neutralizing activity is the live Virus Neutralization Test (VNT).
View Article and Find Full Text PDFBackground: Data from literature shows that antigen tests are rapid and helpful tools for diagnosis of COVID-19.
Aim: This work aimed to evaluate the performances of the Elecsys SARS-CoV-2 Antigen test, in comparison to RT-qPCR, the gold standard.
Methods: A total of 110 swabs were tested; according to rRT-PCR, 76 were positive, and 34 were negative.
Int Immunopharmacol
December 2021
A large number of immunoassays have been developed to detect specific anti-SARS-CoV-2 antibodies; however, not always they are functional to neutralize the virus. The reference test for the anti-spike neutralizing antibodies (nAbs) ability to counteract the viral infection is the virus neutralization test (VNT). Great interest is developing on reliable serological assays allowing antibodies concentration and antibody protective titer correlation.
View Article and Find Full Text PDFBackground And Aims: SARS-CoV-2 antibody assays are relevant in managing the COVID-19 pandemic, providing valuable data on the immunization status of the population. However, current serology tests are highly variable, due to their different characteristics and to the lack of reference materials. The aim of the World Health Organization (WHO) first International Standard (IS) for anti-SARS-CoV-2 immunoglobulin is to harmonize humoral immune response assessment after natural infection or vaccination, and recommend reporting the results for binding activity in Binding Antibody Units (BAU).
View Article and Find Full Text PDFThe antibody response to SARS-CoV-2 has not yet fully defined, but the availability of sensitive and specific serological assays is crucial to observe the presence of specific antibodies against the human receptor binding domain (S-RBD) and high specificity ACE-2-binding antibodies or neutralizing antibodies (NT) in response to vaccines. Indeed, these peculiar antibodies should prevent viral interaction between RBD and Angiotensin-Converting Enzyme 2 (ACE2) receptor, located on surface of host cells. In this study, 72 samples from 37 hospitalized COVID-19 patients and 35 not-hospitalized patients were analyzed longitudinally.
View Article and Find Full Text PDF