Background: As one of the most requested profiles of blood tests, there is a need for standardization among liver function tests (LFT). Alanine aminotransferase (ALT) and aspartate aminotransferase (AST) are key markers of hepatocellular injury. ALT and AST are used to calculate a Fibrosis-4 (FIB-4) score for assessing liver fibrosis.
View Article and Find Full Text PDFObjectives: Laboratories need to take into consideration the specificity and imprecision of assays not only in verification, but also of quality assessment. This study investigates the composition of serum used in EQA materials by comparing material from a single and multiple donors (pooled material), across multiple methods, using creatinine as an example.
Methods: Sixteen different serum matrices were distributed as 36 specimens through the UK NEQAS for Acute and Chronic Kidney Disease Scheme from March 2022 to March 2023.
Objectives: Current liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications for circulating androgen measurements are technically diverse. Previously, variable results have been reported for testosterone. Data are scarce for androstenedione and absent for dehydroepiandrosterone sulfate (DHEAS).
View Article and Find Full Text PDFIt is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs).
View Article and Find Full Text PDFA secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature.
View Article and Find Full Text PDFBackground: Inter-assay variation between different immunoassays and different mass spectrometry methods hampers the biochemical confirmation of male hypogonadism. Furthermore, some laboratories utilise assay manufacturer reference ranges that do not necessarily mirror assay performance characteristics, with the lower limit of normality ranging from 4.9 nmol/L to 11 nmol/L.
View Article and Find Full Text PDFInter-assay variation between different immunoassays and different mass spectrometry methods hampers the biochemical confirmation of male hypogonadism. Furthermore, some laboratories utilis eassay manufacturer reference ranges that do not necessarily mirror assay performance characteristics, with the lower limit of normality ranging from 4.9 nmol/L to 11 nmol/L.
View Article and Find Full Text PDFBackground: A sample received in the laboratory from a patient receiving total parenteral nutrition (TPN) indicated that the patient may have renal dysfunction, but the results were not considered to be reliable enough to report. Investigations using a reference method for measurement of creatinine confirmed positive interference in the creatinine assay and distribution of samples via an External Quality Assessment (EQA) Scheme showed that this positive interference was method dependent.
Methods: Residual TPN fluid (Nutriflex Lipid Special) left in the bag after the patient had completed the infusion was collected and added to a patient serum pool in increasing amounts and distributed to different laboratories for analysis of creatinine and glucose through an EQA Scheme.
Background: National Health Service England issued a Patient Safety Alert in 2014 mandating all acute Trusts in England to implement Acute Kidney Injury (AKI) warning stage results and to do so using a standardised algorithm. In 2021, the Renal and Pathology Getting It Right First Time (GIRFT) teams found significant variation in AKI reporting across the UK. A survey was designed to capture information on the entire AKI detection and alerting process to investigate the potential sources of this unwarranted variation.
View Article and Find Full Text PDFAnn Clin Biochem
September 2023
Background: UK Clinical laboratories have been routinely reporting an estimated glomerular filtration rate (eGFR) based on creatinine measurements using an eGFR equation since the early 2000s. Though there have been recommendations to use enzymatic based creatinine assays, and a recommendation of which equation to use, there still remains a high degree of variation in calculated eGFR results.
Methods: Data from the UK NEQAS for Acute and Chronic Kidney Disease Scheme have been reviewed to look at the CKD equations that are currently in use in the UK and the impact on eGFR results reported.
Objectives: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is recommended for measuring circulating steroids. However, assays display technical heterogeneity. So far, reproducibility of corticosteroid LC-MS/MS measurements has received scant attention.
View Article and Find Full Text PDFMale hypogonadism (MH) is a common endocrine disorder. However, uncertainties and variations in its diagnosis and management exist. There are several current guidelines on testosterone replacement therapy that have been driven predominantly by single disciplines.
View Article and Find Full Text PDFObjectives: External quality assessment (EQA) with commutable samples is used for assessing agreement of results for patients' samples. We investigated the feasibility to aggregate results from four different EQA schemes to determine the bias between different measurement procedures and a reference target value.
Methods: We aggregated EQA results for creatinine from programs that used commutable EQA material by calculating the relative difference between individual participant results and the reference target value for each sample.
Establishing metrological traceability to an assigned value of a matrix-based certified reference material (CRM) that has been validated to be commutable among available end-user measurement procedures (MPs) is central to producing equivalent results for the measurand in clinical samples (CSs) irrespective of the clinical laboratory MPs used. When a CRM is not commutable with CSs, the bias due to noncommutability will be propagated to the CS results causing incorrect metrological traceability to the CRM and nonequivalent CS results among different MPs. In a commutability assessment, a conclusion that a CRM is commutable or noncommutable for use with a specific MP is made when the difference in bias between the CRM and CSs meets or does not meet a criterion for that specific MP when compared to other MPs.
View Article and Find Full Text PDFDried blood spots (DBS) are used for the analysis of more than 2000 biomarkers. We assessed a range of analyte concentrations and diameters of DBS. DBS samples were created by the application of increasing volumes of whole blood prepared by the UK NEQAS Quality Assurance Laboratory.
View Article and Find Full Text PDFAims/hypothesis: The aim of this study was to provide data from a contemporary population-representative cohort on rates and predictors of renal decline in type 1 diabetes.
Methods: We used data from a cohort of 5777 people with type 1 diabetes aged 16 and older, diagnosed before the age of 50, and representative of the adult population with type 1 diabetes in Scotland (Scottish Diabetes Research Network Type 1 Bioresource; SDRNT1BIO). We measured serum creatinine and urinary albumin/creatinine ratio (ACR) at recruitment and linked the data to the national electronic healthcare records.
A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs.
View Article and Find Full Text PDFA process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP.
View Article and Find Full Text PDFCommutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs.
View Article and Find Full Text PDFError methods - compared with uncertainty methods - offer simpler, more intuitive and practical procedures for calculating measurement uncertainty and conducting quality assurance in laboratory medicine. However, uncertainty methods are preferred in other fields of science as reflected by the guide to the expression of uncertainty in measurement. When laboratory results are used for supporting medical diagnoses, the total uncertainty consists only partially of analytical variation.
View Article and Find Full Text PDFBackground: The IFCC Committee for Standardization of Thyroid Function Tests intended to standardize free thyroxine (FT) immunoassays. We developed a Système International d'Unités traceable conventional reference measurement procedure (RMP) based on equilibrium dialysis and mass spectrometry. We describe here the latest studies intended to recalibrate against the RMP and supply a proof of concept, which should allow continued standardization efforts.
View Article and Find Full Text PDFExternal Quality Assurance (EQA) is vital to ensure acceptable analytical quality in medical laboratories. A key component of an EQA scheme is an analytical performance specification (APS) for each measurand that a laboratory can use to assess the extent of deviation of the obtained results from the target value. A consensus conference held in Milan in 2014 has proposed three models to set APS and these can be applied to setting APS for EQA.
View Article and Find Full Text PDF