Publications by authors named "Fides R Schwartz"

Photon-counting computed tomography (PCCT) has shown promising advancements in abdominal imaging in clinical use. Though more peer-reviewed primary literature is needed, this commentary explores PCCT's potential applications, focusing on enhancing diagnostic accuracy, optimizing radiation dose management, and improving patient care. PCCT offers improved spatial and contrast resolution, lower image noise, and reduced radiation dose.

View Article and Find Full Text PDF

Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130-138.

View Article and Find Full Text PDF

Objective: Different methods can be used to condition imaging systems for clinical use. The purpose of this study was to assess how these methods complement one another in evaluating a system for clinical integration of an emerging technology, photon-counting computed tomography (PCCT), for thoracic imaging.

Methods: Four methods were used to assess a clinical PCCT system (NAEOTOM Alpha; Siemens Healthineers, Forchheim, Germany) across 3 reconstruction kernels (Br40f, Br48f, and Br56f).

View Article and Find Full Text PDF

Purpose: Photon-counting detector CT (PCD CT) is a promising technology for abdominal imaging due to its ability to provide high spatial and contrast resolution images with reduced patient radiation exposure. However, there is currently no consensus regarding the optimal imaging protocols for PCD CT. This article aims to present the PCD CT abdominal imaging protocols used by two tertiary care academic centers in the United States.

View Article and Find Full Text PDF

CSF-venous fistulas (CVFs), which are an increasingly recognized cause of spontaneous intracranial hypotension (SIH), are often diminutive in size and exceedingly difficult to detect by conventional imaging. This purpose of this study was to compare energy-integrating detector (EID) CT myelography and photon-counting detector (PCD) CT myelography in terms of image quality and diagnostic performance for detecting CVFs in patients with SIH. This retrospective study included 38 patients (15 men and 23 women; mean age, 55 ± 10 [SD] years) with SIH who underwent both clinically indicated EID CT myelography (slice thickness, 0.

View Article and Find Full Text PDF

Purpose: To prospectively compare the image quality of high-resolution, low-dose photon-counting detector CT (PCD-CT) with standard energy-integrating-detector CT (EID) on the same patients.

Method: IRB-approved, prospective study; patients received same-day non-contrast CT on EID and PCD-CT (NAEOTOM Alpha, blinded) with clinical protocols. Four blinded radiologists evaluated subsegmental bronchial wall definition, noise, and overall image quality in randomized order (0 = worst; 100 = best).

View Article and Find Full Text PDF

Objectives: To determine whether image reconstruction with a higher matrix size improves image quality for lower extremity CTA studies.

Methods: Raw data from 50 consecutive lower extremity CTA studies acquired on two MDCT scanners (SOMATOM Flash, Force) in patients evaluated for peripheral arterial disease (PAD) were retrospectively collected and reconstructed with standard (512 × 512) and higher resolution (768 × 768, 1024 × 1024) matrix sizes. Five blinded readers reviewed representative transverse images in randomized order (150 total).

View Article and Find Full Text PDF

Photon-counting computed tomography (PCCT) offers better high-resolution and noise performance than energy integrating detector (EID) CT. In this work, we compared both technologies for imaging of the temporal bone and skull base. A clinical PCCT system and 3 clinical EID CT scanners were used to image the American College of Radiology image quality phantom using a clinical imaging protocol with matched CTDI vol (CT dose index-volume) of 25 mGy.

View Article and Find Full Text PDF

Introduction: Biomarkers are needed to identify patients with metastatic renal cell carcinoma (mRCC) most likely to benefit from immune checkpoint inhibitors. We examined associations between radiographically assessed body composition (BC) variables and body mass index (BMI) with clinical outcomes for patients with mRCC receiving first-line ipilimumab + nivolumab (ipi/nivo).

Patients And Methods: We retrospectively reviewed all patients with mRCC treated with first-line ipi/nivo at one institution before June 1, 2021 with an analyzable baseline computed tomography (CT) scan.

View Article and Find Full Text PDF

Objectives: Evaluate a novel algorithm for noise reduction in obese patients using dual-source dual-energy (DE) CT imaging.

Methods: Seventy-nine patients with contrast-enhanced abdominal imaging (54 women; age: 58 ± 14 years; BMI: 39 ± 5 kg/m, range: 35-62 kg/m) from seven DECT (SOMATOM Flash or Force) were retrospectively included (01/2019-12/2020). Image domain data were reconstructed with the standard clinical algorithm (ADMIRE/SAFIRE 2), and denoised with a comparison (ME-NLM) and a test algorithm (rank-sparse kernel regression).

View Article and Find Full Text PDF

Purpose: To compare liver fat quantification between MRI and photon-counting CT (PCCT).

Method: A cylindrical phantom with inserts containing six concentrations of oil (0, 10, 20, 30, 50 and 100%) and oil-iodine mixtures (0, 10, 20, 30 and 50% fat +3 mg/mL iodine) was imaged with a PCCT (NAEOTOM Alpha) and a 1.5 T MRI system (MR 450w, IDEAL-IQ sequence), using clinical parameters.

View Article and Find Full Text PDF

Photon-counting computed tomography (PCCT) imaging uses a new detector technology to provide added information beyond what can already be obtained with current CT and MR technologies. This review provides an overview of PCCT of the abdomen and focuses specifically on applications that benefit the most from this new imaging technique. We describe the requirements for a successful abdominal PCCT acquisition and the challenges for clinical translation.

View Article and Find Full Text PDF

Prospective head-to-head comparison of coronary calcium scores between standard computed tomography (CT) and photon-counting CT show no significant differences, while photon-counting CT administers substantially lower radiation dose.

View Article and Find Full Text PDF

Purpose To determine whether photon-counting CT (PCCT) acquisition of whole-body CT images provides similar quantitative image quality and reader satisfaction for multiple myeloma screening at lower radiation doses than does standard energy-integrating detector (EID) CT. Materials and Methods Patients with monoclonal gammopathy of undetermined significance prospectively underwent clinical noncontrast whole-body CT with EID and same-day PCCT (August-December 2021). Five axial scan locations were evaluated by seven radiologists, with 11% (eight of 70) of images including osteolytic lesions.

View Article and Find Full Text PDF

Objectives: To compare the image quality and hepatic metastasis detection of low-dose deep learning image reconstruction (DLIR) with full-dose filtered back projection (FBP)/iterative reconstruction (IR).

Methods: A contrast-detail phantom consisting of low-contrast objects was scanned at five CT dose index levels (10, 6, 3, 2, and 1 mGy). A total of 154 participants with 305 hepatic lesions who underwent abdominal CT were enrolled in a prospective non-inferiority trial with a three-arm design based on phantom results.

View Article and Find Full Text PDF

Photon-counting detector (PCD) CT represents the most recent generational advance in CT technology. PCD CT has the potential to reduce image noise, improve spatial resolution and contrast resolution, and provide multispectral capability, all of which may be achieved with an overall decrease in the radiation dose. These effects may be used to reduce the iodinated contrast media dose and potentially obtain multiphase images through a single-acquisition technique.

View Article and Find Full Text PDF

Background Current imaging methods for prediction of complete margin resection (R0) in patients with pancreatic ductal adenocarcinoma (PDAC) are not reliable. Purpose To investigate whether tumor-related and perivascular CT radiomic features improve preoperative assessment of arterial involvement in patients with surgically proven PDAC. Materials and Methods This retrospective study included consecutive patients with PDAC who underwent surgery after preoperative CT between 2012 and 2019.

View Article and Find Full Text PDF

Background Reliance on examination reporting of unexpected imaging findings does not ensure receipt of findings or appropriate follow-up. A closed-loop communication system should include provider and patient notifications and be auditable through the electronic health record (EHR). Purpose To report the initial design of and results from using an EHR-integrated unexpected findings navigator (UFN) program that ensures closed-loop communication of unexpected nonemergent findings.

View Article and Find Full Text PDF

This article will review critical components for the successful completion of a multi-institution, multiauthor collaborative paper. Best practices for the creation and publication of a collaborative paper will be addressed.

View Article and Find Full Text PDF

Objective: To assess the diagnostic performance and reader confidence in determining the resectability of pancreatic cancer at computed tomography (CT) using a new deep learning image reconstruction (DLIR) algorithm.

Methods: A retrospective review was conduct of on forty-seven patients with pathologically confirmed pancreatic cancers who underwent baseline multiphasic contrast-enhanced CT scan. Image data sets were reconstructed using filtered back projection (FBP), hybrid model-based adaptive statistical iterative reconstruction (ASiR-V) 60 %, and DLIR "TrueFidelity" at low(L), medium(M), and high strength levels(H).

View Article and Find Full Text PDF
Article Synopsis
  • Liver transplantation is a key treatment for severe liver disease in kids, with living donor liver transplantation (LDLT) being a common option involving the left lateral segment (LLS) of the liver.
  • The study examined 50 patients to find a reliable formula for estimating LLS volume (LLSV) using CT scans, but ultimately found that traditional demographic factors did not effectively predict LLSV.
  • The conclusion suggests that donor candidates should be evaluated on an individual basis without excluding them due to their size, as LLSV was difficult to accurately predict.
View Article and Find Full Text PDF