Introduction: Expanded hemodialysis (HDx), being based on medium cut-off (MCO) membranes, improves the removal of medium molecule uremic toxins. HDx efficacy has been proven with blood flow rates (Qb) of 350-400 ml/min, while low Qb have only been assessed in single sessions. We evaluated the effectiveness of HDx in patients with tunneled central venous catheters (CVCs) and low Qb over six months, comparing it with high-flux hemodialysis (HF-HD).
View Article and Find Full Text PDFAims: The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test.
View Article and Find Full Text PDFSARS-CoV-2 transmission has been high, especially among healthcare workers worldwide during the first wave. Vaccination is recognized as the most effective approach to combat the pandemic, but hesitation to get vaccinated represents an obstacle. Another important issue is the duration of protection after administration of the full vaccination cycle.
View Article and Find Full Text PDFGEM Premier ChemSTAT is a whole-blood analyzer designed for providing a rapid basic metabolic panel, inclusive of creatinine and blood urea nitrogen, with the unique characteristic of providing measured bicarbonate (HCO) levels. The aim of this work was to evaluate the clinical performance of HCO assessment with this analyser in a real-life hemodialysis setting. Imprecision was calculated at different HCO levels, along with assay comparison with Gem Premier 4000 analysers.
View Article and Find Full Text PDFObjectives: The current literature on diagnosis of periprosthetic joint infection (PJI) provides controversial evidence on the diagnostic accuracy of D-dimer. Therefore, this critical literature search and meta-analysis was aimed to summarize the diagnostic accuracy of D-dimer for diagnosing PJI.
Content: We searched MEDLINE, Scopus, and Web of Science, for studies on D-dimer for diagnosing PJI, according to the PRISMA flowchart.
Background Filling of citrate tubes with appropriate amount of blood is essential for obtaining reliable results of coagulation testing. This study aimed to verify whether results of routine coagulation tests are comparable when the new Becton Dickinson Vacutainer® Citrate Plus tubes are filled at minimum or optimal volume. Methods The study population consisted of 133 patients (40 on oral anticoagulant therapy), who had blood collected for routine coagulation testing.
View Article and Find Full Text PDFThis study aimed to verify glucose stability within centrifuged serum and lithium-heparin tubes stored at room temperature (RT) or 4 °C. Sixty paired serum (plus gel separator), lithium-heparin (plus gel separator) and K-EDTA tubes were centrifuged within 30 min from collection. Thirty serum and lithium-heparin tubes were then stored at RT, whilst the other 30 serum and lithium-heparin tubes were kept at 4 °C.
View Article and Find Full Text PDFWith these recommendations the Interdisciplinary Urinalysis Group (GIAU) aims to stimulate the following aspects : improvement and standardization of the post analytical approach to physical, chemical and morphological urine examination (ECMU); emphasize the value added to ECMU by selection of clinically significant parameters, indication of analytical methods, of units of measurement, of reference values; improvement of interpretation of dip stick urinalysis with particular regard to the reconsideration of the diagnostic significance of the evaluated parameters together with an increasing awareness of the limits of sensitivity and specificity of this analytical method. Accompanied by the skills to propose and carry out in-depth investigations with analytical methods that are more sensitive and specific;increase the awareness of the importance of professional skills in the field of urinary morphology and their relationships with the clinicians. through the introduction, in the report, of descriptive and interpretative comments depending on the type of request, the complexity of the laboratory, the competence of the pathologist;implement a policy of evaluation of the analytical quality by using, in addition to traditional internal and external controls, a program for the evaluation of morphological competence.
View Article and Find Full Text PDFAims: The presence of cold agglutinin in blood samples can cause a spontaneous agglutination of red blood cells (RBCs) when low temperature occurs. This phenomenon causes a spurious lowering of RBC count on the automated haematological analysers that are detected by incongruous values (≥370 g/L) of the mean cellular haemoglobi concentration (MCHC). A preheating at 37°C can remove the RBC agglutination generally resulting in a reliable count.
View Article and Find Full Text PDFIn clinical laboratories performing routine activities, the need to answer the burning clinical question in emerging field may be limited by lack of technology support or assays accessibility. Commercially available methods, although originally validated for specific biological matrices, may be employed for other matrices, following appropriate guidelines such as Clinical and Laboratory Standards Institute (CLSI) EP 19. We investigated the use of a vancomycin assay with synovial fluid samples, in view of a possible employment in vancomycin release study.
View Article and Find Full Text PDFIntroduction: This retrospective study was undertaken to define cut-off values for synovial fluid (SF) leukocyte count and neutrophil percentage for differentiating aseptic failure and periprosthetic joint infection (PJI) and to evaluate the diagnostic accuracy of blood inflammatory markers, and microbiological testing according to the criteria proposed by the International Consensus Meeting (ICM) of Philadelphia.
Methods: All patients who underwent revision total knee arthroplasty from January 2010 to July 2015 were included: we identified and classified 31 PJIs and 136 aseptic joints. The diagnostic performance of single test was assessed by receiver operating characteristic curve analyses.
In recent years, several automated analysers that prepare and stain blood smears have been introduced in clinical laboratories. Despite the use of instrumental settings based on physical characteristic of individual samples, traumatic injuries of neutrophil and lymphocytes can be observed. Some samples present a very high percentage of damaged cells, allowing the speculation that a cellular susceptibility may enhance mechanical traumatism.
View Article and Find Full Text PDFBackground: This study was planned to assess the impact of pre-treating synovial fluid (SF) samples with hyaluronidase (HY), defining the best procedure for optical microscopy (OM) analysis and evaluating the performance of Sysmex XN-9000 Body Fluid module (XN-BF).
Methods: The cell count by OM was carried out both with and without HY pre-treatment, and using 3 different types of staining reagents. The evaluation of XN-BF included data comparison with OM (100 SFs), carryover, Limit of Blank (LoB), Limit of Detection (LoD), Limit of Quantitation (LoQ) and linearity.