Aim: To estimate the short-term cost-per-controlled-patient with type 2 diabetes mellitus with liraglutide 1.2mg/day vs. sitagliptin 100mg/day as add-on treatment to metformin in Italy.
View Article and Find Full Text PDFThe aim of this study was to compare GnRHa trigger and luteal addition of triptorelin to hCG trigger for final oocyte maturation in women at high risk for OHSS undergoing IVF. A total of 423 patients were divided in two groups both stimulated using antagonist short protocol. Gonadotropins 75-150 UI/day were started on day 2-5, GnRH antagonist was added when the lead follicle was >14 mm and the final trigger was obtained with hCG 250 µg or triptorelin 0.
View Article and Find Full Text PDFBackground: Previous reports revealed poor performance in identifying drugs of abuse users through first-level workplace drug testing (WDT), based on urine samples. In a cross-sectional study, we evaluated: (i) the effect of creatinine normalization of drug values from diluted urine samples (creatinine levels ≤ 20 mg/dL) on the prevalence of drug users; (ii) the independent procedure-related predictors of positivity and dilution.
Methods: Workers' urine samples were collected at the workplace or at our certified laboratory between 2008 and 2012.
Background: Identification of atrial fibrillation (AF) is a clinical imperative. Heartbeat interval time series are increasingly available from personal monitors, allowing new opportunity for AF diagnosis.
Goal: Previously, we devised numerical algorithms for identification of normal sinus rhythm (NSR), AF, and SR with frequent ectopy using dynamical measures of heart rate.
Atrial fibrillation (AF) is usually detected by inspection of the electrocardiogram waveform, a task made difficult when the signal is distorted by noise. The RR interval time series is more frequently available and accurate, yet linear and nonlinear time series analyses that detect highly varying and irregular AF are vulnerable to the common finding of frequent ectopy. We hypothesized that different nonlinear measures might capture characteristic features of AF, normal sinus rhythm (NSR), and sinus rhythm (SR) with frequent ectopy in ways that linear measures might not.
View Article and Find Full Text PDFA pulsed, tunable, narrow band radiation source with frequency in the THz region can be obtained collecting the coherent transition radiation produced by a train of ultra-short electron bunches having picosecond scale inter-distance. In this paper, we review the techniques feasible at the SPARC_LAB test facility to produce and manipulate the requested train of electron bunches and we examine the dynamics of their acceleration and compression. In addition, we show how the performances of the train compression and the radiation intensity and bandwidth can be significantly improved through the insertion of a fourth order harmonic cavity, working in the X-band and acting as a longitudinal phase space linearizer.
View Article and Find Full Text PDFThe incidence of coronary artery aneurysms (CAA) in the general population ranges from 0.3% to 5.3%.
View Article and Find Full Text PDFWe present the experimental evidence of the generation of coherent and statistically stable two-color free-electron laser radiation obtained by seeding an electron beam double peaked in energy with a laser pulse single spiked in frequency. The radiation presents two neat spectral lines, with time delay, frequency separation, and relative intensity that can be accurately controlled. The analysis of the emitted radiation shows a temporal coherence and a shot-to-shot regularity in frequency significantly enhanced with respect to the self-amplified spontaneous emission.
View Article and Find Full Text PDFIntroduction: Modifications of hearth rate variability (HRV) constitute a marker of the autonomic nervous system (ANS) deregulation, a promising pathway linking job strain (JS) and cardiovascular diseases (CVD). The study objective is to assess whether exposures to recent and prolonged JS reduce time-domain HRV parameters on working days (WD) among CVD-susceptible nurses and whether the association also persists on resting days (RD).
Material And Methods: 313 healthy nurses were investigated twice with one year interval to assess JS based on the demand-control and the effort-reward models.
Background: Non-linear heart rate variability (HRV) indices were hypothesized to correlate with cardiac function, fluid overload and physical performance in hemodialysis patients.
Methods: Twenty-four-hour Holter electrocardiograms were recorded in patients enrolled in the Frequent Hemodialysis Network (FHN) Daily Dialysis Trial. Correlations between non-linear HRV indices and left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), extracellular volume (ECV)/total body water (TBW) ratio, the SF-36 Physical Health Composite (PHC) and Physical Functioning (PF) scores were tested.
Objective: Due to the burden of coronary heart disease (CHD), the monitoring of CHD trends is required. This study sought to examine the acute myocardial infarction (AMI) trends in attack and mortality rates, and in 28-day case-fatality, in six European populations during 1985-2010.
Methods: Data consisted of 78 128 AMI events included in eight population-based registries from Finland (several populations), Italy (Brianza and Varese), Germany (Augsburg), France (Haute-Garonne), Spain (Girona) and Estonia (Tallinn).
To face the increased demand for bandwidth, cost-effectiveness and simplicity of future Ethernet data communications, a comparison between two different solutions based on directly-modulated VCSEL sources and Silicon Photonics technologies is carried out. Also by exploiting 4-PAM modulation, the transmission of 50-Gb/s and beyond capacity per channel is analyzed by means of BER performance. Applications for optical backplane, very short reach and in case of client-optics networks and intra and inter massive data centers communications (up to 10 km) are taken into account.
View Article and Find Full Text PDFThe hypothesis that central volume plays a key role in the source of low frequency (LF) oscillations of heart rate variability (HRV) was tested in a population of end stage renal disease patients undergoing conventional hemodialysis (HD) treatment, and thus subject to large fluid shifts and sympathetic activation. Fluid overload (FO) in 58 chronic HD patients was assessed by whole body bioimpedance measurements before the midweek HD session. Heart Rate Variability (HRV) was measured using 24-hour Holter electrocardiogram recordings starting before the same HD treatment.
View Article and Find Full Text PDFIntroduction And Objectives: To estimate the cost-effectiveness of rosuvastatin versus simvastatin, atorvastatin and pitavastatin in Spain, according to the European guidelines for the treatment of dyslipidemias in patients with high and very high cardiovascular risk.
Methods: A Markov long-term cost-effectiveness model of rosuvastatin versus simvastatin, atorvastatin and pitavastatin in patients with high and very high cardiovascular risk defined according to 5 factors (sex, age, smoking habit, baseline cholesterol level, and systolic blood pressure) using the SCORE system. The incremental cost-effectiveness ratio is expressed in euros per quality adjusted life years and is calculated according to the perspective of the Spanish National Health System.
The two-dimensional single shot transverse coherence of the Self-Amplified Spontaneous Emission of the SPARC_LAB Free-Electron Laser was measured through the statistical analysis of a speckle field produced by heterodyning the radiation beam with a huge number of reference waves, scattered by a suspension of particles. In this paper we report the measurements and the evaluation of the transverse coherence along the SPARC_LAB undulator modules. The measure method was demonstrated to be precise and robust, it does not require any a priori assumptions and can be implemented over a wide range of wavelengths, from the optical radiation to the x-rays.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
June 2016
We have developed numerical approaches to dynamical analysis of heart rates, measured as interbeat or RR, intervals, based on entropy and fluctuation analyses in a large data base of consecutive Holter monitor recordings. In Part I, we present a RR interval-based classifier that distinguishes normal sinus rhythm (NSR), atrial fibrillation (AF) and sinus rhythm with ectopy with an accuracy of 99%, 81% and 77%respectively, using 10-minute segments. In Part II, we present 2-year mortality estimation based on the entropy calculations.
View Article and Find Full Text PDFBackground: Before introducing long-term cardiovascular disease (CVD) risk models in clinical practice, their external validity should be investigated. We assessed the validity of the CArdiovascular Monitoring Unit in Northern Italy (CAMUNI) 20-year risk score, developed in Northern Italy, and published previously, when applied to a population with different risk factors distribution and event incidence.
Methods: The validation sample consisted of 5307 35-69 year-old subjects (2418 men) enrolled in Central Italy during the 1980s (Malattia ATerosclerotica Istituto Superiore di Sanità (MATISS) study).
The aim of this study was to evaluate the effect of ultrasound (US) (600 W, 20 kHz and 95.2 μm wave amplitude; 10 or 30 min at 20, 30 or 44 ± 1 °C) and pulsed light (PL) (Xenon lamp; 3 pulses/s; 0.1 m distance; 2.
View Article and Find Full Text PDFInt Arch Occup Environ Health
July 2015
Objectives: Longitudinal studies have linked stress at work with a higher incidence of musculoskeletal pain. We aimed to explore the extent to which musculoskeletal pain is a cause as opposed to a consequence of perceived occupational stress.
Methods: As part of the international cultural and psychosocial influences on disability study, we collected information from 305 Italian nurses, at baseline and again after 12 months, about pain during the past month in the low-back and neck/shoulder, and about effort-reward imbalance (ERI) (assessed by Siegrist's ERI questionnaire).
The aim of this retrospective analysis was to evaluate the association between serum levels of various hormones and in vitro fertilization (IVF) parameters in poor responder patients. Serum levels of anti-Müllerian hormone (AMH), dehydroepiandrosterone sulfate (DHEAS), androstenedione and testosterone were measured before the start of IVF treatment cycle. We found that serum AMH and DHEAS levels were positively correlated with the number of mature oocytes, fertilized oocytes and developed embryos, both in pregnant and in non-pregnant patients.
View Article and Find Full Text PDFVery high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators.
View Article and Find Full Text PDFBackground: Erythropoiesis-stimulating agents (ESAs) have been investigated in small studies in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). Erythropoiesis-stimulating agents did not show a clear effect on left ventricular function or clinical outcome, but some studies suggested an increased risk of thromboembolic events.
Methods: A systematic literature search in MEDLINE was performed, until December 2012.