Publications by authors named "Ferrario D"

Numerous studies are focused on nanoparticle penetration into the brain functionalizing them with ligands useful to cross the blood-brain barrier. However, cell targeting is also crucial, given that cerebral pathologies frequently affect specific brain cells or areas. Functionalize nanoparticles with the most appropriate targeting elements, tailor their physical parameters, and consider the brain's complex anatomy are essential aspects for precise therapy and diagnosis.

View Article and Find Full Text PDF
Article Synopsis
  • - Chronic ulcers greatly impact patients' quality of life and result in significant healthcare costs, necessitating a thorough approach to treatment that considers the wound's cause and characteristics.
  • - During the wound's healing phase, especially epithelialization, techniques such as grafting are recommended to speed up healing, enhance scar quality, and manage pain effectively.
  • - Follicular unit auto-grafting using a scalp punch is a preferred minimally invasive method for wound repair, offering benefits for patient recovery and comfort compared to traditional methods.
View Article and Find Full Text PDF

Introduction: Chronic lymphocytic leukemia (CLL), the most common leukemia in Western countries, is a mature B-cell chronic lymphoproliferative disorder characterized by the accumulation of neoplastic CD5+ B lymphocytes, functionally incompetent and usually monoclonal in origin, in bone marrow, lymph nodes and blood. Diagnosis occurs predominantly in elderly patients, with a median age reported between 67 and 72 years. CLL has a heterogeneous clinical course, which can vary from indolent to, less frequently, aggressive forms.

View Article and Find Full Text PDF

The use of 24-h ambulatory blood pressure monitoring (ABPM) has been continuously increasing over the last decades. However, cuff-based devices may cause discomfort, particularly at night, leading to potentially non-representative blood pressure (BP) values. We investigated the feasibility of a cuff-less BP monitoring solution in 67 subjects undergoing conventional 24-h ABPM.

View Article and Find Full Text PDF

This work presents a method to minimize the inadvertent cutting of tissues in surgeries involving bone drilling. We present electrical impedance measurements as an assistive technology to image-guided surgery to achieve online guidance. Proposed concept is to identify and localize the landmarks via impedance measurements and then use this information to superimpose the estimated drilling trajectory on the offline maps obtained by pre-operative imaging.

View Article and Find Full Text PDF

Peripheral oxygen saturation (SpO2) plays a key role in diagnosing sleep apnea. It is mainly measured via transmission pulse oximetry at the fingertip, an approach less suited for long-term monitoring over several nights.In this study we tested a more patient-friendly solution via a reflectance pulse oximetry device.

View Article and Find Full Text PDF

The state-of-the-art non-invasive measurement of peripheral oxygen saturation (SpO2) during sleep is mainly based on pulse oximetry at the fingertip. Although this approach is noninvasive, it can still be obtrusive and cumbersome to apply, in particular for ambulatory monitoring over several nights.We developed a wrist-worn reflectance pulse oximetry device which can be embedded in a watch, making it less obtrusive and easy to apply.

View Article and Find Full Text PDF

Classical approaches for measuring high-quality ECG require the use of gel electrodes and individually shielded cables, which limit patient comfort, especially in long-term use. We recently introduced a novel sensing architecture-so-called cooperative sensors-that allow the use of active dry electrodes connected by two unshielded wires. The aim of this work is to qualitatively evaluate an ECG recorded with a dry-electrode cooperative-sensor system.

View Article and Find Full Text PDF

The current non-invasive gold standard for the measurement of blood pressure (BP) is the oscillometric cuff at the upper arm, despite its known limitations. In particular, its poor adequacy with continuous monitoring and its measurement incommodity call for the development of simpler and more convenient solutions. Among these, solutions based on pulse wave analysis (PWA) and photoplethysmography (PPG) are of particular interest, due to their low-cost, strong patient compliance, and applicability in and out of clinical settings.

View Article and Find Full Text PDF

The measurement of peripheral oxygen saturation (SpO2) in neonatal intensive care units (NICUs) poses a significant challenge. Motion artifacts due to the patient's limb motion induce many false alarms, which in turn cause an additional workload for the medical staff and anxiety for the parents. We developed a reflectance pulse oximeter dedicated to be placed at the patient's forehead, which is less prone to such artifacts.

View Article and Find Full Text PDF

Background: Nodular fasciitis is a benign pseudosarcomatous, self-limited, and reactive process. Based on its clinical and histological features - a fast-growing, solitary tumor with high cellularity and mitotic count - nodular fasciitis is considered to be a benign mimic of sarcoma.

Methods: We present four cases of nodular fasciitis and a review of the literature.

View Article and Find Full Text PDF

Bone's resistance to fracture depends on several factors, such as bone mass, microarchitecture, and tissue material properties. The clinical assessment of bone strength is generally performed by Dual-X Ray Photon Absorptiometry (DXA), measuring bone mineral density (BMD) and trabecular bone score (TBS). Although it is considered the major predictor of bone strength, BMD only accounts for about 70% of fragility fractures, while the remaining 30% could be described by bone "quality" impairment parameters, mainly related to tissue microarchitecture.

View Article and Find Full Text PDF

Reported studies pertaining to needle guidance suggest that tissue impedance available from neuromonitoring systems can be used to discriminate nerve tissue proximity. In this pilot study, the existence of a relationship between intraoperative electrical impedance and tissue density, estimated from computer tomography (CT) images, is evaluated in the mastoid bone of in vivo sheep. In five subjects, nine trajectories were drilled using an image-guided surgical robot.

View Article and Find Full Text PDF

Classical approaches to make high-quality measurements of biopotential signals require the use of shielded or multi-wire cables connecting the electrodes to a central unit in a star arrangement. Consequently, increasing the number of leads increases cabling and connector complexity which is not only limiting patient comfort but also anticipated as the main limiting factor for future miniaturization and cost reduction of tomorrow's wearables. We have recently introduced a novel sensing architecture that significantly reduces cabling complexity by eliminating shielded or multi-wire cables as well as by allowing simple connectors thanks to a bus arrangement.

View Article and Find Full Text PDF

This study presents a modelling system to evaluate the impact of weight reduction in light commercial vehicles with diesel engines on air quality and greenhouse gas emissions. The PROPS model assesses the emissions of one vehicle in the aforementioned category and its corresponding reduced-weight version. The results serve as an input to the RIAT+ tool, an air quality integrated assessment modelling system.

View Article and Find Full Text PDF

Knowledge of an individual's skin condition is important for pressure ulcer prevention. Detecting early changes in skin through perfusion, oxygen saturation values, and pressure on tissue and subsequent therapeutic intervention could increase patients' quality of life drastically. However, most existing sensing options create additional risk of ulcer development due to further pressure on and chafing of the skin.

View Article and Find Full Text PDF

Increasing evidence suggests that inorganic arsenic, a major environmental pollutant, exerts immunosuppressive effects in epidemiological, in vitro, and animal models. The mechanisms, however, remain unclear, and little is known about variation in susceptibilities due to age and sex. We performed a review of the experimental and epidemiologic evidence on the association of arsenic exposure and immune diseases.

View Article and Find Full Text PDF
Article Synopsis
  • LTMS-S is an innovative wearable system that tracks multiple physiological signals like ECG, heart rate, breathing rate, SpO2, core body temperature, and physical activity, all using just three sensors in a vest.
  • Each sensor operates independently with features like a rechargeable battery, memory, and wireless communication, and can run for over 24 hours on a single charge.
  • The paper discusses the clinical validation results of the LTMS-S system, showing its effectiveness in monitoring these vital signs.
View Article and Find Full Text PDF

Hypothesis: A multielectrode probe in combination with an optimized stimulation protocol could provide sufficient sensitivity and specificity to act as an effective safety mechanism for preservation of the facial nerve in case of an unsafe drill distance during image-guided cochlear implantation.

Background: A minimally invasive cochlear implantation is enabled by image-guided and robotic-assisted drilling of an access tunnel to the middle ear cavity. The approach requires the drill to pass at distances below 1  mm from the facial nerve and thus safety mechanisms for protecting this critical structure are required.

View Article and Find Full Text PDF

Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a multi-lead electrocardiogram or a thoracic bioimpedance.This paper starts by analysing the state-of-the-art methods to simultaneously measure biopotential and bioimpedance signals, and justifies why currently (1) passive electrodes require the use of shielded or double-shielded cables, and (2) active electrodes require the use of multi-wired cabled technologies, when aiming at high quality physiological measurements.

View Article and Find Full Text PDF

This glossary was developed to provide technical references to support work in the field of the alternatives to animal testing. It was compiled from various existing reference documents coming from different sources and is meant to be a point of reference on alternatives to animal testing. Giving the ever-increasing number of alternative test methods and approaches being developed over the last decades, a combination, revision, and harmonization of earlier published collections of terms used in the validation of such methods is required.

View Article and Find Full Text PDF