Publications by authors named "Ferrando V"

In this work, we present two new multifocal intraocular lens (MIOL) designs, both based on the silver mean kinoform diffractive lens. We demonstrate that a single aperiodic diffractive profile can be used to create two different MIOLs: one with a kinoform structure and the other with a stepwise profile. Quantitative assessment of the designs was carried out using the through focus modulation transfer function and the area under the modulation transfer function for the prediction of their visual performance.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate, in distance runners, the acute effects of moderate durations (60 s per leg) of static (SS) and dynamic stretching (DS) on running economy (RE) and performance.

Methods: Twelve recreational runners completed a randomized crossover design. Initially, the second ventilatory threshold (VT2) and the speed associated with the maximal oxygen uptake (VO2max) (vVO2max) were determined through an incremental test.

View Article and Find Full Text PDF

Objective: The digital transformation of daily routines has increased visual demands, especially at intermediate and near distances. The Devil multifocal intraocular lens (MIOL) design was developed to enhance intermediate visual performance. This design is a novel trifocal intraocular lens inspired by the fractal structure known as the 'Devil's staircase'.

View Article and Find Full Text PDF

In this work, we present a new family of Zone Plates (ZPs) designed using the self-generating Kolakoski sequence. The focusing and imaging properties of these aperiodic diffractive lenses coined Kolakoski Zone Plates (KZPs) are extensively studied. It is shown that under monochromatic plane-wave illumination, a KZP produces two main foci of the same intensity along the axial axis.

View Article and Find Full Text PDF

The aim of this study was to investigate the effects on running performance of a within-session placebo procedure consisting of a conditioning treatment plus verbal communications. Twenty-six subjects were assigned to PLACEBO and CONTROL groups. Participants performed three sessions: Session 1-Cooper Test, Session 2-Baseline session and Session 3-Experimental session.

View Article and Find Full Text PDF

Background: The aim of this study was to assess the effectiveness of a new Short Intermittent Taekwondo Test (SITT) in 17 black belt athletes.

Methods: Maximal oxygen uptake (V̇O2max), carbon dioxide production (V̇CO2), respiratory exchange ratio (RER), heart rate (HR), and blood lactate concentration [La] during treadmill cardiopulmonary exercise test (CPET) and SITT were compared. SITT started with 10 sec of all-out kicks, alternating legs, and progressively increasing 5 s on each stage until the 4 stage.

View Article and Find Full Text PDF

The design and implementation of a multiplexed spiral phase mask in an experimental optical tweezers setup are presented. This diffractive optical element allows the generation of multiple concentric vortex beams with independent topological charges and without amplitude modulation. The generalization of the phase mask for multiple concentric vortices is also shown.

View Article and Find Full Text PDF

Purpose: To compare the effects between resisted sled sprint training (RSS) and unresisted sprint training (URS) on sprint and acceleration performance, vertical jump, and maximal strength during an 8-week period of preseason training.

Methods: Twenty-six recreational active rugby players were randomly divided into either RSS or URS training groups and then performed 8 weeks of training, 2 sessions/wk of sprint-specific training program. The RSS group performed sprints by towing a sled overloaded with 12.

View Article and Find Full Text PDF

Background: Corneal refractive surgery induces high-order aberrations, specifically spherical aberration (SA). These aberrations can have implications when patients later develop cataracts and require the implantation of multifocal intraocular lenses (MIOLs). MIOLs with asymmetric designs pose challenges in predicting outcomes, particularly in these cases.

View Article and Find Full Text PDF

Evaluating chromatic aberration for a multifocal intraocular lens (MIOL) in vitro is essential for studying its performance because it helps determine the most appropriate lens for each patient, enhancing surgical outcomes. While refractive MIOLs with angular power variation have shown positive clinical outcomes, studies of these MIOLs on optical benches primarily employed monochromatic green light, neglecting the impact of longitudinal chromatic aberration (LCA) on MIOL performance. To address this gap, we evaluated the through-focus modulation transfer function (TF-MTF) and the point spread function (PSF) of two refractive segmented extended depth of focus intraocular lenses (IOLs) (Femtis Comfort and Precizon Presbyopic), comparing the results with those obtained with two widely known diffractive multifocal intraocular lenses (AcrySof IQ ReSTOR and FineVision Pod F).

View Article and Find Full Text PDF

In this work, we propose a new diffractive trifocal intraocular lens design with focus extension, conceived to provide a high visual performance at intermediate distances. This design is based on a fractal structure known as the "Devil's staircase". To assess its optical performance, numerical simulations have been performed with a ray tracing program using the Liou-Brennan model eye under polychromatic illumination.

View Article and Find Full Text PDF

Influenza A viruses (IAV) cause annual epidemics and occasional pandemics in humans. The most recent pandemic outbreak occurred in 2009 with H1N1pdm09. This virus, which most likely reassorted in swine before its transmission to humans, was reintroduced into the swine population and continues circulating ever since.

View Article and Find Full Text PDF

Purpose: To compare the effects of 2 small-sided games (SSGs), shuttle running within the bout (SSG-S) versus possession play only (SSG-P) on acute physiological and metabolic responses, perception of effort, and performance.

Methods: Ten young elite male soccer players (age 18.6 [1.

View Article and Find Full Text PDF

Paralympic powerlifting (PP), formerly known as "International Paralympic Committee" (IPC) powerlifting, is the format of powerlifting adapted for athletes with disabilities, and it differs from the version for able-bodied athletes in that it consists of bench press only. According to the mandate of the IPC, PP athletes should be enabled to achieve sporting excellence. As such, rigorous evidence is needed.

View Article and Find Full Text PDF

Optical manipulation is interfacing disciplines in the micro and nanoscale, from molecular biology to quantum computation. Versatile solutions for increasingly more sophisticated technological applications require multiple traps with which to maneuver dynamically several particles in three dimensions. The axial direction is usually overlooked due to difficulties in observing particles away from an objective-lens focal plane, a normal element in optical tweezers, and in managing interparticle distances along the trapping beam propagating direction, where strong radiation pressure and shadowing effects compromise the simultaneous and stable confinement of the particles.

View Article and Find Full Text PDF

Background: This study investigated the acute effects of two high-intensity interval training (HIIT) programs on physiological responses and internal workload. Methods: Ten national-level adolescent male rowers (age: 15.7 ± 0.

View Article and Find Full Text PDF

This study aimed to evaluate in vitro performance refractive segmented EDOF intraocular lenses under polychromatic light using an optical bench that complies with the ISO 11979-2 Norm. The through focus modulation transfer function (TF-MTF) of the Femtis Comfort LS-313 MF15 (Oculentis GmbH, Berlin, Germany) IOL was evaluated for IOLs with three different base powers. The effect of the asymmetry of the segmented designs was evaluated with 3 different wavelengths and with polychromatic light at a 3.

View Article and Find Full Text PDF

Most of the new premium models of intraocular lenses for presbyopia correction use diffractive optics in their optical design. The presence of multiple foci and the difference of the diffractive efficiency for different wavelengths have a great impact in the lens optical performance. In this context, there is a limited information available for clinicians to understand the optical principles that differentiate each design and their potential influence on clinical outcomes.

View Article and Find Full Text PDF

Research in infection biology aims to understand the complex nature of host-pathogen interactions. While this knowledge facilitates strategies for preventing and treating diseases, it can also be intentionally misused to cause harm. Such dual-use risk is potentially high for highly pathogenic microbes such as Risk Group-3 (RG3) bacteria and RG4 viruses, which could be used in bioterrorism attacks.

View Article and Find Full Text PDF

This study compared the effects of two breathing conditions during the freestyle turn approach phase in swimmers. Thirty-four prepubertal swimmers (mean ± SD: 10.59 ± 0.

View Article and Find Full Text PDF

This randomized crossover counterbalanced study investigated, in recreational runners, the acute effects of pre-exercise stretching on physiological and metabolic responses, endurance performance, and perception of effort. Eight male endurance runners (age 36 ± 11 years) performed three running-until-exhaustion tests, preceded by three warm-ups, including the following different stretching protocols: static (SS), dynamic (DS), and no-stretching (NS). During the SS and DS sessions, the warm-up consisted of 10 min of running plus 5 min of SS or DS, respectively, while during the NS session, the warm-up consisted of 15 min of running.

View Article and Find Full Text PDF

A crucial ability for athletes playing sports that involve coincidence timing actions is the motor timing ability. The efficiency of perceptual and motor processes underlying the motor timing ability has been related to the motor experience gained in interceptive sports, such as tennis. In the present study, the motor timing ability in young tennis players (TP) and age-matched control participants (CTRL) was compared by means of a synchronization paradigm.

View Article and Find Full Text PDF

Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate.

View Article and Find Full Text PDF