Publications by authors named "Fernando Leyton"

The aim of this work was to propose a preliminary local diagnostic reference levels (DRL) for pediatric interventional cardiology (PIC) procedures in Argentina, for different ranges of age and weight. This work has been conducted in the framework of the "Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean" (OPRIPALC) program coordinated by the World Health Organization and the Pan American Health Organization in cooperation with the International Atomic Energy Agency to ensuring that radiation exposures of pediatric patients are the minimum necessary during fluoroscopy-guided interventional procedures. The local DRL values presented in this paper by weight group and age group were 7.

View Article and Find Full Text PDF

Studies have reported cases of radiation-induced cataract among cardiology professionals. In view of the evidence of epidemiological studies, the ICRP recommends a new threshold for opacities and a new radiation dose to eye lens limit of 20mSv per year for occupational exposure. The aim of this paper is to report scattered radiation doses at the height of the operator's eye in an interventional cardiology facility without considering radiation protection devices and to correlate these values with different angiographic projections and operational modes.

View Article and Find Full Text PDF

Area monitoring is a fundamental test at radiodiagnostic facilities to maintain an acceptable level of radiation exposure for employees and members of the public. Experimental measurements were taken in an ionising radiation calibration laboratory. Four area monitor instruments were used.

View Article and Find Full Text PDF

The purpose of this paper was to estimate mean glandular dose levels (DG) in six digital mammography systems in Santiago, Chile, and to propose preliminary reference levels to execute mammography in Chile. The study was carried out assessing two direct digital systems and four computer-based radiography (CR) systems. Estimates of DG were calculated for different thicknesses of polymethyl methacrylate according to the quality control protocol in digital mammography of the Spanish Society of Medical Physics and NHSBSP Equipment Report 0604 Version 3.

View Article and Find Full Text PDF

Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey.

View Article and Find Full Text PDF

Purpose: The aim of this study was to present the results of a pilot program on patient dosimetry carried out in Chile during the last 5 yr, using a biplane x-ray angiography system settled for pediatrics. This research was conducted in Latin America under the auspices of the International Atomic Energy Agency (IAEA) supporting programs on radiological protection (RP) of patients.

Methods: Patient age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time, and two dosimetric quantities [air kerma-area product (P(ka)) and cumulative dose (CD) at the patient entrance reference point] were recorded for each procedure.

View Article and Find Full Text PDF

The aim of this work is to present a methodology and some initial results for a pilot program on radiation protection (RP) in pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. The starting point of the program was a workshop involving several pediatric cardiologists leading this specialty in 11 Latin American countries. The workshop included a pilot RP training course and additional sessions during which the objectives of the program and the methodology to collect and process data on patient and staff radiation doses were discussed.

View Article and Find Full Text PDF

Radiation dose and image quality for paediatric protocols in all five X-ray fluoroscopy systems used for interventional cardiology procedures existing in Chile have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object (TO) and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-16 cm of PMMA). Images from fluoroscopy (low (FL), medium and high) and cine (CI) modes have been archived in DICOM format.

View Article and Find Full Text PDF

Interventional cardiology procedures usually imply high doses to the staff, as paediatric cardiologists need to stay closer to the patient than during adult procedures. Also, biplane systems are used that imply an additional source of staff doses. The objective of this paper is to measure scatter doses in four X-ray systems, using polymethyl methacrylate phantoms with thicknesses ranging from 4 to 16 cm to simulate paediatric patients, for the different acquisition modes.

View Article and Find Full Text PDF

In pediatric interventional cardiology, cardiologists need to stay closer to the patient than during adult catheterization, and the use of biplane systems increases the scatter radiation. Occupational radiation risk is rather high, and estimation of lens doses becomes necessary. Deriving factors for assessing these doses from the patient doses displayed in catheterization laboratories can help in preserving staff radiation safety.

View Article and Find Full Text PDF