Publications by authors named "Fernando Garay"

This work reports an amperometric enzyme-electrode prepared with glucose oxidase, which have been immobilized by a cross-linking step with glutaraldehyde in a mixture containing albumin and a novel carbon nanotubes-mucin composite (CNT-muc). The obtained hydrogel matrix was trapped between two polycarbonate membranes and then fixed at the surface of a Pt working electrode. The developed biosensor was optimized by evaluating different compositions and the analytical properties of an enzymatic matrix with CNT-muc.

View Article and Find Full Text PDF

Under International Atomic Energy Agency regional programme TSA3 Radiological Protection of Patients in Medical Exposures, Latin American countries evaluated the image quality and glandular doses for digital mammography equipment with the purpose of seeing the performance and compliance with international recommendations. Totally, 24 institutions participated from Brazil, Chile, Costa Rica, El Salvador, Mexico, Paraguay and Venezuela. Signal difference noise ratio results showed for CR poor compliance with tolerances; better results were obtained for full-field digital mammography equipment.

View Article and Find Full Text PDF

Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey.

View Article and Find Full Text PDF

Propofol is a widely used, potent intravenous anesthetic for ambulatory anesthesia and long-term sedation. The target steady state concentration of propofol in blood is 0.25-10 μg/mL (1-60 μM).

View Article and Find Full Text PDF

2,6-Diisopropylphenol (propofol) is a potent anesthetic drug with fast onset of the anesthetic effect and short recovery time for the patients. Outside of the United States, propofol is widely used in performing target controlled infusion anesthesia. With the long term vision of an electrochemical sensor for in vivo monitoring and feedback controlled dosing of propofol in blood, different alternatives for the electrochemical quantification of propofol using diverse working electrodes and experimental conditions are presented in this contribution.

View Article and Find Full Text PDF

An amperometric sensor for lactate quantification is presented. The developed biosensor requires only 0.2 U of lactate oxidase, which is immobilized in a mucin/albumin hydrogel matrix.

View Article and Find Full Text PDF

Robust surface-bound insulating polymer films with controlled thickness in <5 nm range are important for technological advances in diverse disciplines such as electrochemical sensors, molecular electronics, separations and anti-corrosive coatings. Creating these films by simple methods from readily available materials has been a significant challenge. Here we report a newly synthesized molecule combining a styrene and thiol moieties, joined via a short linker, that binds to the gold surface, polymerizes and crosslinks polymer chains to form robust films with uniform and controlled thickness and complete surface coverage.

View Article and Find Full Text PDF

This article presents a simple chronoamperometric immunosensor for the quantitative assessment of creatine kinase MB (CK-MB) in 50 microL undiluted serum samples. The immunosensor consists of gold working and counter electrodes patterned onto a glass chip by thin-film photolithography and an external Ag|AgCl reference electrode. The detection limit (DL) of the chronoamperometric method is 13 ng mL(-1) (DL = 2xRMSD/S, where RMSD is the residual mean standard deviation of the measured points around a calibration curve with a slope of S).

View Article and Find Full Text PDF

The theoretical model presented in part 1 of this work is employed to simulate and fit experimental probe beam deflection (PBD) data of Fe(CN)6(3-)/Fe(CN)6(4-) and Fe3+/Fe2+ couples. Current and beam deviation dependency on time at constant potential (chronoamperometry and chronodeflectometry) is analyzed via a new treatment based on the migration and diffusion properties of all the species involved. The diffusion coefficients of electroactive species are obtained by fitting chronoamperometric curves.

View Article and Find Full Text PDF

The theoretical framework of a general model for the simulation of concentration profiles of electroactive and nonelectroactive species, driven by an electrochemical process under potentiostatic conditions, is presented. Based on this analysis, finite differences simulations are performed to calculate the actual profiles under different experimental conditions. Furthermore, the effect of experimental parameters (diffusion coefficients of the ions of the redox couple or the supporting electrolyte, charge of the different species, etc.

View Article and Find Full Text PDF

A probe beam deflection (PBD) study of ion exchange between an electroactive polymer poly(allylamine)-bipyridyl-pyridine osmium complex film and liquid electrolyte is reported. The PBD measurements were made simultaneously to chronoamperometric oxidation-reduction cycles, to be able to detect kinetic effects in the ion exchange. Layer-by-layer (LbL) self-assembled redox polyelectrolyte films with osmium bipyridyl complex covalently attached to poly(allylamine) (PAH-Os) and poly(styrene sulfonate) (PSS) have been built by alternate electrostatic adsorption from soluble polyelectrolytes.

View Article and Find Full Text PDF