Individual ion mass spectrometry (IMS) is the Orbitrap-based extension of the niche mass spectrometry technique known as charge detection mass spectrometry (CDMS). While traditional CDMS analysis is performed on in-house-built instruments such as the electrostatic linear ion trap, IMS extends CDMS analysis to Orbitrap analyzers, allowing charge detection analysis to be available to the scientific community at large. IMS simultaneously measures the mass-to-charge ratios (m/z) and charges (z) of hundreds to thousands of individual ions within one acquisition event, creating a spectral output directly into the mass domain without the need for further spectral deconvolution.
View Article and Find Full Text PDFCharge detection mass spectrometry (CDMS) is a well-established technique that provides direct mass spectral outputs regardless of analyte heterogeneity or molecular weight. Over the past few years, it has been demonstrated that CDMS can be multiplexed on Orbitrap analyzers utilizing an integrated approach termed individual ion mass spectrometry (IMS). To further increase adaptability, robustness, and throughput of this technique, here, we present a method that utilizes numerous integrated equipment components including a Kingfisher system, SampleStream platform, and Q Exactive mass spectrometer to provide a fully automated workflow for immunoprecipitation, sample preparation, injection, and subsequent IMS acquisition.
View Article and Find Full Text PDFMotivation: Post-translational modifications (PTMs) on proteins regulate protein structures and functions. A single protein molecule can possess multiple modification sites that can accommodate various PTM types, leading to a variety of different patterns, or combinations of PTMs, on that protein. Different PTM patterns can give rise to distinct biological functions.
View Article and Find Full Text PDFExisting mass spectrometric assays used for sensitive and specific measurements of target proteins across multiple samples, such as selected/multiple reaction monitoring (SRM/MRM) or parallel reaction monitoring (PRM), are peptide-based methods for bottom-up proteomics. Here, we describe an approach based on the principle of PRM for the measurement of intact proteoforms by targeted top-down proteomics, termed proteoform reaction monitoring (PfRM). We explore the ability of our method to circumvent traditional limitations of top-down proteomics, such as sensitivity and reproducibility.
View Article and Find Full Text PDFThe molecular identification of tissue proteoforms by top-down mass spectrometry (TDMS) is significantly limited by throughput and dynamic range. We introduce AutoPiMS, a single-ion MS based multiplexed workflow for top-down tandem MS (MS) directly from tissue microenvironments in a semi-automated manner. AutoPiMS directly off human ovarian cancer sections allowed for MS identification of 73 proteoforms up to 54 kDa at a rate of <1 min per proteoform.
View Article and Find Full Text PDFBlood serum and plasma are arguably the most commonly analyzed clinical samples, with dozens of proteins serving as validated biomarkers for various human diseases. Top-down proteomics may provide additional insights into disease etiopathogenesis since this approach focuses on protein forms, or proteoforms, originally circulating in blood, potentially providing access to information about relevant post-translational modifications, truncations, single amino acid substitutions, and many other sources of protein variation. However, the vast majority of proteomic studies on serum and plasma are carried out using peptide-centric, bottom-up approaches that cannot recapitulate the original proteoform content of samples.
View Article and Find Full Text PDFAnalysis of intact proteins by mass spectrometry enables direct quantitation of the specific proteoforms present in a sample and is an increasingly important tool for biopharmaceutical and academic research. Interpreting and quantifying intact protein species from mass spectra typically involves many challenges including mass deconvolution and peak processing as well as determining optimal spectral averaging parameters and matching masses to theoretical proteoforms. Each of these steps can present informatic hurdles, as parameters often need to be tailored specifically to the data sets.
View Article and Find Full Text PDFAnnu Rev Biomed Data Sci
August 2023
Alternative splicing is pivotal to the regulation of gene expression and protein diversity in eukaryotic cells. The detection of alternative splicing events requires specific omics technologies. Although short-read RNA sequencing has successfully supported a plethora of investigations on alternative splicing, the emerging technologies of long-read RNA sequencing and top-down mass spectrometry open new opportunities to identify alternative splicing and protein isoforms with less ambiguity.
View Article and Find Full Text PDFNative mass spectrometry has recently moved alongside traditional structural biology techniques in its ability to provide clear insights into the composition of protein complexes. However, to date, limited software tools are available for the comprehensive analysis of native mass spectrometry data on protein complexes, particularly for experiments aimed at elucidating the composition of an intact protein complex. Here, we introduce ProSight Native as a start-to-finish informatics platform for analyzing native protein and protein complex data.
View Article and Find Full Text PDFMotivation: Post-translational modifications (PTMs) on proteins regulate protein structures and functions. A single protein molecule can possess multiple modification sites that can accommodate various PTM types, leading to a variety of different patterns, or combinations of PTMs, on that protein. Different PTM patterns can give rise to distinct biological functions.
View Article and Find Full Text PDFThe high-throughput quantification of intact proteoforms using a label-free approach is typically performed on proteins in the 0-30 kDa mass range extracted from whole cell or tissue lysates. Unfortunately, even when high-resolution separation of proteoforms is achieved by either high-performance liquid chromatography or capillary electrophoresis, the number of proteoforms that can be identified and quantified is inevitably limited by the inherent sample complexity. Here, we benchmark label-free quantification of proteoforms of by applying gas-phase fractionation (GPF) via field asymmetric ion mobility spectrometry (FAIMS).
View Article and Find Full Text PDFG protein-coupled receptors (GPCRs) are the largest family of membrane receptors in humans. They mediate nearly all aspects of human physiology and thus are of high therapeutic interest. GPCR signaling is regulated in space and time by receptor phosphorylation.
View Article and Find Full Text PDFUnraveling the complexity of biological systems relies on the development of new approaches for spatially resolved proteoform-specific analysis of the proteome. Herein, we employ nanospray desorption electrospray ionization mass spectrometry imaging (nano-DESI MSI) for the proteoform-selective imaging of biological tissues. Nano-DESI generates multiply charged protein ions, which is advantageous for their structural characterization using tandem mass spectrometry (MS/MS) directly on the tissue.
View Article and Find Full Text PDFIt is important for the proteomics community to have a standardized manner to represent all possible variations of a protein or peptide primary sequence, including natural, chemically induced, and artifactual modifications. The Human Proteome Organization Proteomics Standards Initiative in collaboration with several members of the Consortium for Top-Down Proteomics (CTDP) has developed a standard notation called ProForma 2.0, which is a substantial extension of the original ProForma notation developed by the CTDP.
View Article and Find Full Text PDFThe effectiveness of any proteomics database search depends on the theoretical candidate information contained in the protein database. Unfortunately, candidate entries from protein databases such as UniProt rarely contain all the post-translational modifications (PTMs), disulfide bonds, or endogenous cleavages of interest to researchers. These omissions can limit discovery of novel and biologically important proteoforms.
View Article and Find Full Text PDFHuman biology is tightly linked to proteins, yet most measurements do not precisely determine alternatively spliced sequences or posttranslational modifications. Here, we present the primary structures of ~30,000 unique proteoforms, nearly 10 times more than in previous studies, expressed from 1690 human genes across 21 cell types and plasma from human blood and bone marrow. The results, compiled in the Blood Proteoform Atlas (BPA), indicate that proteoforms better describe protein-level biology and are more specific indicators of differentiation than their corresponding proteins, which are more broadly expressed across cell types.
View Article and Find Full Text PDFThe Human Proteoform Atlas (HPfA) is a web-based repository of experimentally verified human proteoforms on-line at http://human-proteoform-atlas.org and is a direct descendant of the Consortium of Top-Down Proteomics' (CTDP) Proteoform Atlas. Proteoforms are the specific forms of protein molecules expressed by our cells and include the unique combination of post-translational modifications (PTMs), alternative splicing and other sources of variation deriving from a specific gene.
View Article and Find Full Text PDFMethods of antibody detection are used to assess exposure or immunity to a pathogen. Here, we present Ig-MS, a novel serological readout that captures the immunoglobulin (Ig) repertoire at molecular resolution, including entire variable regions in Ig light and heavy chains. Ig-MS uses recent advances in protein mass spectrometry (MS) for multiparametric readout of antibodies, with new metrics like Ion Titer (IT) and Degree of Clonality (DoC) capturing the heterogeneity and relative abundance of individual clones without sequencing of B cells.
View Article and Find Full Text PDFMethods of antibody detection are used to assess exposure or immunity to a pathogen. Here, we present Ig-MS , a novel serological readout that captures the immunoglobulin (Ig) repertoire at molecular resolution, including entire variable regions in Ig light and heavy chains. Ig-MS uses recent advances in protein mass spectrometry (MS) for multi-parametric readout of antibodies, with new metrics like Ion Titer (IT) and Degree of Clonality (DoC) capturing the heterogeneity and relative abundance of individual clones without sequencing of B cells.
View Article and Find Full Text PDFProtein fragmentation is a critical component of top-down proteomics, enabling gene-specific protein identification and full proteoform characterization. The factors that influence protein fragmentation include precursor charge, structure, and primary sequence, which have been explored extensively for collision-induced dissociation (CID). Recently, noticeable differences in CID-based fragmentation were reported for native versus denatured proteins, motivating the need for scoring metrics that are tailored specifically to native top-down mass spectrometry (nTDMS).
View Article and Find Full Text PDFAn Orbitrap-based ion analysis procedure determines the direct charge for numerous individual protein ions to generate true mass spectra. This individual ion mass spectrometry (IMS) method for charge detection enables the characterization of highly complicated mixtures of proteoforms and their complexes in both denatured and native modes of operation, revealing information not obtainable by typical measurements of ensembles of ions.
View Article and Find Full Text PDFTop-down proteomics studies intact proteoform mixtures and offers important advantages over more common bottom-up proteomics technologies, as it avoids the protein inference problem. However, achieving complete molecular characterization of investigated proteoforms using existing technologies remains a fundamental challenge for top-down proteomics. Here, we benchmark the performance of ultraviolet photodissociation (UVPD) using 213 nm photons generated by a solid-state laser applied to the study of intact proteoforms from three organisms.
View Article and Find Full Text PDF