Aims: The use of ultrasound (US)-guided venous puncture for cardiac pacing/defibrillation lead placement may minimize the risk of periprocedural complications and radiation exposure. However, none of the published studies have been sufficiently powered to recommend this approach as the standard of care. We compare the safety and efficacy of ultrasound-guided axillary venous puncture (US-AVP) vs.
View Article and Find Full Text PDFBackground: Nowadays, 49% of patients with pacemakers are older than 80 years old. Nevertheless, mortality and change in functional status after pacemaker implantation are not well documented in elderly patients.
Objective: We designed a prospective study to analyze the cardiovascular mortality and change in functional status of elderly patients, medium-long term after pacemaker implantation.
Background: Nowadays, 49% of patients with pacemakers are older than 80 years old. Nevertheless, mortality and change in functional status after pacemaker implantation are not well documented in elderly patients.
Objective: We designed a prospective study to analyze cardiovascular mortality and change in functional status of elderly patients, medium-long term after pacemaker implantation.
J Cardiovasc Electrophysiol
September 2019
Introduction: The most widespread venous sites of access for implantation intravenous implantable cardiac electronic device (CIED) are the cephalic and subclavian vein. Fluoroscopy-guided axillary venous access is an alternative, but efficacy and safety have not been studied under equal conditions. The aim of the present study is to compare the efficacy and safety of fluoroscopy-guided axillary vs cephalic vein access in CIED implant.
View Article and Find Full Text PDFPacemaker-induced superior vena cava syndrome (SVCS) is a rare but incapacitating adverse event that can occur years after implantation. Inasmuch as it is a rare disease, there is no consensus about its treatment. The most widely used option is balloon angioplasty and venous stent implantation, with preservation of the lead or previous extraction and subsequent reimplantation after the procedure, which is associated with new episodes of thrombosis.
View Article and Find Full Text PDFA 41-year-old man with a history of tachycardia refractory to multiple antiarrhythmic drugs was sent to our institution. His 12-lead electrocardiogram demonstrated incessant narrow QRS complex tachycardia with negative waves in the inferior leads and long RP interval. Occasionally, the tachycardia terminated after a wave and then was restarted after a sinusal beat.
View Article and Find Full Text PDF