We describe the case of an 18-year-old male Army reservist presenting with left lower extremity pain for which he was initially diagnosed with a stress injury. After failing conservative treatment, a radiograph was obtained showing a "lacelike" appearance of the medullary bone in the foot and ankle. Magnetic resonance imaging subsequently demonstrated widespread polyostotic marrow replacement with coarsened trabeculations.
View Article and Find Full Text PDFAs iterative reconstruction in Computed Tomography (CT) is an ill-posed problem, additional prior information has to be used to get a physically meaningful result (close to ground truth if available). However, the amount of influence of the regularisation prior is crucial to the outcome of the reconstruction. Therefore, we propose a scheme for tuning the strength of the prior via a certain image metric.
View Article and Find Full Text PDFGrating-based phase-contrast computed tomography (GBPC-CT) enables increased soft tissue differentiation, but often suffers from streak artifacts when performing high-sensitivity GBPC-CT of biomedical samples. Current GBPC-CT setups consist of one-dimensional gratings and hence allow to measure only the differential phase-contrast (DPC) signal perpendicular to the direction of the grating lines. Having access to the full two-dimensional DPC signal can strongly reduce streak artefacts showing up as characteristic horizontal lines in the reconstructed images.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
November 2017
X-ray computed tomography (CT) is a powerful noninvasive technique for investigating the inner structure of objects and organisms. However, the resolution of laboratory CT systems is typically limited to the micrometer range. In this paper, we present a table-top nanoCT system in conjunction with standard processing tools that is able to routinely reach resolutions down to 100 nm without using X-ray optics.
View Article and Find Full Text PDFMalignant renal tumors account for 7% of childhood cancers, and Wilms tumors are by far the most common-but not in older children and adolescents. Among individuals in the latter half of their 2nd decade of life, renal cell carcinoma (RCC) is more common than Wilms tumor. The histopathologic spectrum of RCCs in children differs from that in adults.
View Article and Find Full Text PDFObjective: Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment.
Materials And Methods: Institutional review board approval was obtained.
Several dedicated commercial lab-based micro-computed tomography (μCT) systems exist, which provide high-resolution images of samples, with the capability to also deliver in-line phase contrast. X-ray phase contrast is particularly beneficial when visualizing very small features and weakly absorbing samples. The raw measured projections will include both phase and absorption effects.
View Article and Find Full Text PDFFollowing the development of energy-sensitive photon-counting detectors using high-Z sensor materials, application of spectral x-ray imaging methods to clinical practice comes into reach. However, these detectors require extensive calibration efforts in order to perform spectral imaging tasks like basis material decomposition. In this paper, we report a novel approach to basis material decomposition that utilizes a semi-empirical estimator for the number of photons registered in distinct energy bins in the presence of beam-hardening effects which can be termed as a polychromatic Beer-Lambert model.
View Article and Find Full Text PDFIn this article, we report on a novel acquisition scheme for time- and dose-saving retrieval of dark-field data in grating-based phase-contrast imaging. In comparison to currently available techniques, the proposed approach only requires two phase steps. More importantly, our method is capable of accurately retrieving the dark-field signal where conventional approaches fail, for instance in the case of very low photon statistics.
View Article and Find Full Text PDFDentin is a mineralized material making up most of the tooth bulk. A system of microtubules, so called dentinal tubules, transverses it radially from the pulp chamber to the outside. This highly oriented structure leads to anisotropic mechanical properties directly connected to the tubules orientation and density: the ultimate tensile strength as well as the fracture toughness and the shear strength are largest perpendicular to dentinal tubules.
View Article and Find Full Text PDFThe purpose of this work is to develop an image-based de-noising algorithm that exploits complementary information and noise statistics from multi-modal images, as they emerge in x-ray tomography techniques, for instance grating-based phase-contrast CT and spectral CT. Among the noise reduction methods, image-based de-noising is one popular approach and the so-called bilateral filter is a well known algorithm for edge-preserving filtering. We developed a generalization of the bilateral filter for the case where the imaging system provides two or more perfectly aligned images.
View Article and Find Full Text PDFX-ray phase-contrast computed tomography (PCCT) using grating interferometry provides enhanced soft-tissue contrast. The possibility to use standard polychromatic laboratory sources enables an implementation into a clinical setting. Thus, PCCT has gained significant attention in recent years.
View Article and Find Full Text PDFChanges in x-ray attenuating tissue caused by lung disorders like emphysema or fibrosis are subtle and thus only resolved by high-resolution computed tomography (CT). The structural reorganization, however, is of strong influence for lung function. Dark-field CT (DFCT), based on small-angle scattering of x-rays, reveals such structural changes even at resolutions coarser than the pulmonary network and thus provides access to their anatomical distribution.
View Article and Find Full Text PDFPropagation-based imaging or inline holography in combination with computed tomography (holotomography) is a versatile tool to access a sample's three-dimensional (3D) micro or nano structure. However, the phase retrieval step needed prior to tomographic reconstruction can be challenging especially for strongly absorbing and refracting samples. Near-field ptychography is a recently developed phase imaging method that has been proven to overcome this hurdle in projection data.
View Article and Find Full Text PDFGrating-based phase-contrast computed tomography (PCCT) is a promising imaging tool on the horizon for pre-clinical and clinical applications. Until now PCCT has been plagued by strong artifacts when dense materials like bones are present. In this paper, we present a new statistical iterative reconstruction algorithm which overcomes this limitation.
View Article and Find Full Text PDFPurpose: The exciting prospect of Spectral CT (SCT) using photon-counting detectors (PCD) will lead to new techniques in computed tomography (CT) that take advantage of the additional spectral information provided. We introduce a method to reduce metal artifact in X-ray tomography by incorporating knowledge obtained from SCT into a statistical iterative reconstruction scheme. We call our method Spectral-driven Iterative Reconstruction (SPIR).
View Article and Find Full Text PDFPhase-contrast x-ray computed tomography has a high potential to become clinically implemented because of its complementarity to conventional absorption-contrast.In this study, we investigate noise-reducing but resolution-preserving analytical reconstruction methods to improve differential phase-contrast imaging. We apply the non-linear Perona-Malik filter on phase-contrast data prior or post filtered backprojected reconstruction.
View Article and Find Full Text PDFStaphylococcus aureus is found on over 90% of atopic dermatitis skin lesions and is thought to contribute to skin inflammation via the production of potent exotoxins. In contrast, less than 5% of normal subjects harbor S. aureus.
View Article and Find Full Text PDFKawasaki disease (KD) is an acute vasculitis of young children that can be complicated by coronary artery abnormalities. Recent findings suggest that a superantigen(s) may play an important role in stimulating the immune activation associated with the disease, although the origin of this superantigen(s) is unclear. Staphylococcus aureus, isolated from the rectum or pharynx of patients with KD, secretes toxic shock syndrome toxin 1 (TSST-1).
View Article and Find Full Text PDFJ Allergy Clin Immunol
August 1999
Background: Peanuts are a common cause of food-induced anaphylaxis and fatalities. Previous studies have demonstrated that rush immunotherapy to crude peanut extract reduces clinical symptoms triggered by oral peanut challenges, but the immunotherapy was associated with an unacceptably high incidence of systemic allergic reactions. One approach to reduce the frequency of allergic reactions would be to use a modified peanut antigen with low allergenic properties.
View Article and Find Full Text PDFMol Gen Mikrobiol Virusol
August 1999
S. aureus isolates from patients with Kawasaki disease (KD) release high levels of extracellular protein A (SpA), as compared to S. aureus in other diseases.
View Article and Find Full Text PDF