Objective: To compare the implant-abutment connection microgap between computer-aided design and computer-aided manufacturing (CAD/CAM) milled or laser-sintered cobalt-chrome custom abutments with or without ceramic veneering and titanium stock abutments with or without crown cementation.
Material And Methods: Six groups of six abutments each were prepared: (1) CAD/CAM cobalt-chrome custom abutments: milled, milled with ceramic veneering, laser-sintered, and laser-sintered with ceramic veneering (four groups: MIL, MIL-C, SIN, and SIN-C, respectively) and (2) titanium stock abutments with or without zirconia crown cementation (two groups: STK and STK-Z, respectively). Abutments were screwed to the implants by applying 30 Ncm torque.
Int J Environ Res Public Health
January 2021
Implant dentistry has evolved over time, resulting in better treatment outcomes for both patients and clinicians. The aim of this trial was to test whether the immediate loading of implants with a platform-switching design influences the marginal bone level, compared to four-week loading, after one year of follow-up. Moreover, a comparison of clinical data regarding implant survival, implant stability, and patient-reported outcome measures (PROMs) was conducted.
View Article and Find Full Text PDFThe aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4).
View Article and Find Full Text PDFMed Oral Patol Oral Cir Bucal
September 2009
Objectives: 1) To evaluate and compare the stability of two types of implants in an animal model after preparing the implant bed with various sequences of osteotomes in bone type IV. 2) To evaluate the hypothesis of whether or not the sequence of using osteotomes influences the primary implant stability.
Material And Method: We selected bone from cow ribs, which in its cross section (the most medullar area of the bone) would be equivalent to a type IV human bone.
Aims: Immediate loading has become a predictable option for treatment, while one of the main requirements for its implementation is obtaining appropriate primary stability in implants. With that aim, conical implants are commercially available, since, according to specialized literature, they provide greater stability. One of the methods to measure implant stability which has evolved to further stages is resonance frequency analysis (RFA).
View Article and Find Full Text PDF