Cardiac magnetic resonance (CMR) has acquired a pivotal role in modern cardiology. It represents the gold standard for biventricular volume and systolic function assessment. Moreover, CMR allows for non-invasive myocardial tissue evaluation, highlighting tissue edema, fibrosis, fibro-fatty infiltration and iron overload.
View Article and Find Full Text PDFNumerous studies addressed the topic of behavioral and symptomatic changes in eating disorders. Rates of transition vary widely across studies, ranging from 0 to 70.8%, depending on the diagnoses taken into account and the study design.
View Article and Find Full Text PDFPhotomicrographs of thin sections provide a swift and efficient means of sharing information for consultation, education, documentation and publication within the Geosciences and related areas. In general terms, the main way to capture digital microscopic images involves the use of a mounted camera unit on a high-end costly benchtop microscope. However, freehand methods to capture microscope-scale images using a smartphone, as well as smartphone adapters that can be attached to a microscope have emerged during recent years.
View Article and Find Full Text PDFObjective: The aim of this work was to identify risk predictors of a negative psychological outcome among personal, situational and systemic characteristics of women who choose to interrupt a pregnancy by elective (e.g., not feeling ready for giving birth) or therapeutic means (e.
View Article and Find Full Text PDFAlthough spatially precise systems are now available for small-animal irradiations, there are currently limited software tools available for treatment planning for such irradiations. We report on the adaptation, commissioning, and evaluation of a 3-dimensional treatment planning system for use with a small-animal irradiation system. The 225-kV X-ray beam of the X-RAD 225Cx microirradiator (Precision X-Ray) was commissioned using both ion-chamber and radiochromic film for 10 different collimators ranging in field size from 1 mm in diameter to 40 × 40 mm(2) A clinical 3-dimensional treatment planning system (Metropolis) developed at our institution was adapted to small-animal irradiation by making it compatible with the dimensions of mice and rats, modeling the microirradiator beam orientations and collimators, and incorporating the measured beam data for dose calculation.
View Article and Find Full Text PDFThe first of a new generation of microtron accelerators has been installed and tested. It is currently in use for multisegment conformal radiotherapy at our institution. The unit produces x rays and electrons from 10 to 50 MeV in 5 MeV increments.
View Article and Find Full Text PDFPreclinical evaluation of the therapeutic potential of radiolabeled antibodies is commonly performed in a xenografted nude mouse model. To assess therapeutic efficacy it is important to estimate the absorbed dose to the tumor and normal tissues of the nude mouse. The current study was designed to accurately measure radiation does to human neuroblastoma xenografts and normal organs in nude mice treated with I-131-labeled 3F8 monoclonal antibody (MoAb) against disialoganglioside GD2 antigen.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
March 1994
Purpose: A 50 MeV racetrack microtron has been installed and tested at Memorial Sloan-Kettering Cancer Center. It is designed to execute multi-segment conformal therapy automatically under computer control using scanned X ray and electron beams from 10 to 50 MeV. Prior to acceptance of the machine from the manufacturer, formal reliability testing was carried out.
View Article and Find Full Text PDFThe irradiation of blood before transfusion into immunosuppressed patients is an increasingly common technique used to prevent graft-versus-host disease. A technical procedure is described for the calibration of blood irradiators, including the determination of absolute dose rate and relative dose distribution over the blood volume. Results of dose rate measurements on commercially available irradiators indicate differences of +5% to -13% with manufacturer-supplied calibrations and variations in the relative dose rate over the irradiation volume from 70% to 180%.
View Article and Find Full Text PDF