We report the precise measurements of the cross section of e^{+}e^{-}→hadrons at center-of-mass energies from 3.645 to 3.871 GeV.
View Article and Find Full Text PDFCentrosomes are membrane-less organelles that orchestrate a wide array of biological functions by acting as microtubule organizing centers. Here, we report that caspase-2-driven apoptosis is elicited in blood cells failing cytokinesis and that extra centrosomes are necessary to trigger this cell death. Activation of caspase-2 depends on the PIDDosome multi-protein complex, and priming of PIDD1 at extra centrosomes is necessary for pathway activation.
View Article and Find Full Text PDFDespite major therapeutic advances in the treatment of acute lymphoblastic leukemia (ALL), resistances and long-term toxicities still pose significant challenges. Cyclins and their associated cyclin-dependent kinases are one focus of cancer research when looking for targeted therapies. We discovered cyclin C as a key factor for B-ALL development and maintenance.
View Article and Find Full Text PDFPhys Rev Lett
September 2024
Using data samples collected with the BESIII detector operating at the BEPCII storage ring, the cross section of the inclusive process e^{+}e^{-}→η+X, normalized by the total cross section of e^{+}e^{-}→hadrons, is measured at eight center-of-mass energy points from 2.0000 to 3.6710 GeV.
View Article and Find Full Text PDFUsing (10.087±0.044)×10^{9} J/ψ events collected with the BESIII detector at the BEPCII storage ring, the processes Λp→Λp and Λ[over ¯]p→Λ[over ¯]p are studied, where the Λ/Λ[over ¯] baryons are produced in the process J/ψ→ΛΛ[over ¯] and the protons are the hydrogen nuclei in the cooling oil of the beam pipe.
View Article and Find Full Text PDFATP2B1 is a known regulator of calcium (Ca) cellular export and homeostasis. Diminished levels of intracellular Ca content have been suggested to impair SARS-CoV-2 replication. Here, we demonstrate that a nontoxic caloxin-derivative compound (PI-7) reduces intracellular Ca levels and impairs SARS-CoV-2 infection.
View Article and Find Full Text PDFWe report the measurement of the inclusive cross sections for e^{+}e^{-}→nOCH (where nOCH denotes non-open charm hadrons) with improved precision at center-of-mass (c.m.) energies from 3.
View Article and Find Full Text PDFBased on (10087±44)×10^{6} J/ψ events collected with the BESIII detector, a partial wave analysis of the decay J/ψ→γK_{S}^{0}K_{S}^{0}η^{'} is performed. The mass and width of the X(2370) are measured to be 2395±11(stat)_{-94}^{+26}(syst) MeV/c^{2} and 188_{-17}^{+18}(stat)_{-33}^{+124}(syst) MeV, respectively. The corresponding product branching fraction is B[J/ψ→γX(2370)]×B[X(2370)→f_{0}(980)η^{'}]×B[f_{0}(980)→K_{S}^{0}K_{S}^{0}]=(1.
View Article and Find Full Text PDFWe present measurements of the Born cross sections for the processes e^{+}e^{-}→ωχ_{c1} and ωχ_{c2} at center-of-mass energies sqrt[s] from 4.308 to 4.951 GeV.
View Article and Find Full Text PDFUsing a sample of (10087±44)×10^{6} J/ψ events, which is about 45 times larger than that was previously analyzed, a further investigation on the J/ψ→γ3(π^{+}π^{-}) decay is performed. A significant distortion at 1.84 GeV/c^{2} in the line shape of the 3(π^{+}π^{-}) invariant mass spectrum is observed for the first time, which could be resolved by two overlapping resonant structures, X(1840) and X(1880).
View Article and Find Full Text PDFWe perform a study of the χ_{c1}(3872) line shape using the data samples of e^{+}e^{-}→γχ_{c1}(3872), χ_{c1}(3872)→D^{0}D[over ¯]^{0}π^{0}, and π^{+}π^{-}J/ψ collected with the BESIII detector. The effects of the coupled channels and the off-shell D^{*0} are included in the parametrization of the line shape. The line shape mass parameter is obtained to be M_{X}=(3871.
View Article and Find Full Text PDFUsing e^{+}e^{-} collision data corresponding to an integrated luminosity of 7.33 fb^{-1} recorded by the BESIII detector at center-of-mass energies between 4.128 and 4.
View Article and Find Full Text PDFWe perform for the first time an amplitude analysis of the decay D^{+}→K_{S}^{0}π^{+}η and report the observation of the decay D^{+}→K_{S}^{0}a_{0}(980)^{+} using 2.93 fb^{-1} of e^{+}e^{-} collision data taken at a center-of-mass energy of 3.773 GeV with the BESIII detector.
View Article and Find Full Text PDFWe present cross sections for the reaction e^{+}e^{-}→K_{S}^{0}K_{L}^{0} at center-of-mass energies ranging from 3.51 to 4.95 GeV using data samples collected in the BESIII experiment, corresponding to a total integrated luminosity of 26.
View Article and Find Full Text PDFUsing (10087±44)×10^{6} J/ψ events collected with the BESIII detector, numerous Ξ^{-} and Λ decay asymmetry parameters are simultaneously determined from the process J/ψ→Ξ^{-}Ξ[over ¯]^{+}→Λ(pπ^{-})π^{-}Λ[over ¯](n[over ¯]π^{0})π^{+} and its charge-conjugate channel. The precisions of α_{Λ0} for Λ→nπ^{0} and α[over ¯]_{Λ0} for Λ[over ¯]→n[over ¯]π^{0} compared to world averages are improved by factors of 4 and 1.7, respectively.
View Article and Find Full Text PDFBy analyzing 7.33 fb^{-1} of e^{+}e^{-} annihilation data collected at center-of-mass energies between 4.128 and 4.
View Article and Find Full Text PDFBased on data samples collected with the BESIII detector at the BEPCII collider, the process e^{+}e^{-}→Σ^{+}Σ[over ¯]^{-} is studied at center-of-mass energies sqrt[s]=2.3960, 2.6454, and 2.
View Article and Find Full Text PDFBased on 4.4 fb^{-1} of e^{+}e^{-} annihilation data collected at the center-of-mass energies between 4.60 and 4.
View Article and Find Full Text PDFThe adoption of advanced artificial intelligence (AI) systems in healthcare is transforming the healthcare-delivery landscape. Artificial intelligence may enhance patient safety and improve healthcare outcomes, but it presents notable ethical and legal dilemmas. Moreover, as AI streamlines the analysis of the multitude of factors relevant to malpractice claims, including informed consent, adherence to standards of care, and causation, the evaluation of professional liability might also benefit from its use.
View Article and Find Full Text PDFUsing data samples with an integrated luminosity of 5.85 fb^{-1} collected at center-of-mass energies from 4.61 to 4.
View Article and Find Full Text PDF