A sensitive, rapid and green synchronous spectrofluorimetric method was developed to simultaneously analyze a binary mixture of diosmin (DSM) and hesperidin (HSP). The RSFI of both medications was measured in methanol at Δ of 100 nm. The results indicated that specific experimental factors had an impact on these intensities.

View Article and Find Full Text PDF

A new analytical quality by design-assisted HPLC-UV approach is presented, for the first time, for the concurrent determination of cetirizine (CTZ) and azelastine (AZE) in raw materials, commercial eye drops and aqueous humor. The two drugs are co-administered as eye drops in severe ocular allergies. A 2 full factorial design was adopted for the chromatographic optimization to ensure the best analytical performance and reliability, as well as to save time, effort and solvent consumption.

View Article and Find Full Text PDF

A green, simple and sensitive HPLC method coupled with fluorescence detection was implemented for the quantitative determination of the anti-glaucoma drug tafluprost (TFL). Liquid chromatography was performed on HyperClone™ ODS (C18) column of dimensions; 150 × 4.6 mm i.

View Article and Find Full Text PDF

A new, simple and selective HPLC method was implemented for the simultaneous estimation of tafluprost (TFL) and timolol (TIM) in their new anti-glaucoma combination in the challengeable ratio of 3 and 1000 for TFL and TIM, respectively. Separation was achieved using a BDS Hypersil phenyl column and a mobile phase made up of acetonitrile: 0.015 M phosphate buffer (50:50 v/v, pH 3.

View Article and Find Full Text PDF
Article Synopsis
  • The text discusses the formulation of a tablet named Nemeriv Cp, which combines cetirizine (CET), phenylpropanolamine (PPA), and nimesulide (NMS) to treat nasal congestion, allergies, and associated symptoms, noting a lack of methods for their simultaneous analysis.
  • It presents two new methods for quantifying these three drugs: a spectrophotometric method that measures specific wavelengths and an HPLC method using a monolithic column with a defined mobile phase for separation.
  • The proposed methods were successfully applied to laboratory-prepared tablets and showed satisfactory comparison with existing methods, indicating their reliability for drug analysis.
View Article and Find Full Text PDF

A new simple, accurate and sensitive sequential injection analysis chemiluminescence (CL) detection method for the determination of cefditoren pivoxil (CTP) has been developed. The developed method was based on the enhancement effect of silver nanoparticles on the CL signal arising from a luminol-potassium ferricyanide reaction in the presence of CTP. The optimum conditions relevant to the effect of luminol, potassium ferricyanide and silver nanoparticle concentrations were investigated.

View Article and Find Full Text PDF

A simple, rapid and highly sensitive spectrofluorimetric method was developed for determination of gemifloxacin mesylate (GFX) in tablets. The method is based on measuring the native fluorescence of GFX in isopropanol at 400 nm after excitation at 272 nm. The fluorescence-concentration plot was rectilinear over the range of 0.

View Article and Find Full Text PDF

Rapid, simple and highly sensitive flow-injection (FI) chemiluminescence (CL) and flow-injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'-bipyridyl)ruthenium(II) (Ru(bipy)(3)(2)+). Various experimental parameters affecting CL intensity were carefully studied and optimised.

View Article and Find Full Text PDF

A simple and sensitive spectrofluorimetric method was developed for the determination of ezetimibe in its pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behavior of ezetimibe in sodium dodecyl sulfate (SDS) micellar system. In aqueous solution of acetate buffer pH 5.

View Article and Find Full Text PDF

A chemiluminescent method using flow injection (FI) was investigated for rapid and sensitive determination of enalapril maleate and atenolol, which are used in the treatment of hypertension. The method is based on the sensitizing effect of these drugs on the Ce(IV)-sulfite reaction. The different experimental parameters affecting the chemiluminescence (CL) intensity were carefully studied and incorporated into the procedure.

View Article and Find Full Text PDF

A flow injection chemiluminescent (FI-CL) method was developed for the determination of pioglitazone HCl. It is based on the sensitizing effect of the drug on the oxidation reaction of sulfite with cerium(IV). The different experimental parameters affecting the chemiluminescence intensity, such as concentration of reagents and some physical parameters of the manifold, were carefully studied and incorporated into the procedure.

View Article and Find Full Text PDF

Square-wave adsorptive cathodic stripping voltammetry was used to determine pioglitazone HCl in Britton Robinson buffer of pH5. The adsorptive cathodic peak was observed at -1.5 V vs.