Publications by authors named "Farzana Darain"

Rice starch (RS-)based nano/mesoporous carbon (RSNMC) was prepared via a hard-templating route using cheap rice starch as a carbon source. XRD and TEM characterization indicated the formation of organized nanoporous RSNMC. Nitrogen absorption-desorption studies revealed a high surface area of up to 488 m²∙g, uniform pore size of 3.

View Article and Find Full Text PDF

A central conserved arginine, first identified as a clinical mutation leading to sulfite oxidase deficiency, is essential for catalytic competency of sulfite oxidizing molybdoenzymes, but the molecular basis for its effects on turnover and substrate affinity have not been fully elucidated. We have used a bacterial sulfite dehydrogenase, SorT, which lacks an internal heme group, but transfers electrons to an external, electron accepting cytochrome, SorU, to investigate the molecular functions of this arginine residue (Arg78). Assay of the SorT Mo centre catalytic competency in the absence of SorU showed that substitutions in the central arginine (R78Q, R78K and R78M mutations) only moderately altered SorT catalytic properties, except for R78M which caused significant reduction in SorT activity.

View Article and Find Full Text PDF

A simple and efficient immobilization of streptavidin protein (with hexa-histidine tag) onto the surface of mesoporous NiO is described. Before immobilization of streptavidin protein (with hexa-histidine tag) onto the surface of mesoporous NiO, we first synthesized well-organized mesoporous NiO by a nanocasting method using mesoporous silica SBA-15 as the hard template. Then, the well-organized mesoporous NiO particles were characterized by small angle x-ray diffraction (XRD), wide angle XRD, nitrogen adsorption/desorption, and transmission electron microscopy (TEM).

View Article and Find Full Text PDF

A simple microfluidic immunoassay card was developed based on polystyrene (PS) substrate for the detection of horse IgG, an inexpensive model analyte using fluorescence microscope. The primary antibody was captured onto the PS based on covalent bonding via a self-assembled monolayer (SAM) of thiol to pattern the surface chemistry on a gold-coated PS. The immunosensor chip layers were fabricated from sheets by CO(2) laser ablation.

View Article and Find Full Text PDF

A disposable immunosensor cartridge was developed that allows antibodies to be immobilized on the surface for the detection of myoglobin, a marker for the early assessment of acute myocardial infarction (AMI) using fluorescence techniques. The anti-myoglobin antibody was immobilized on a polystyrene substrate based on covalent bonding via silanization. The immunosensor chip layers were fabricated from sheets by CO(2)-laser ablation.

View Article and Find Full Text PDF

A biosensor based on cytochrome c3 (cyt c3) has been introduced to detect and quantify superoxide radical (O2*-). Cyt c3, isolated from the sulfate-reducing bacterium (Desulfovibrio vulgaris Miyazaki F. strain), and its mutant were immobilized onto a conducting polymer coated electrodes by the covalent bonding with carbodiimide chemistry.

View Article and Find Full Text PDF

A disposable amperometric immunosensor was studied for the rapid detection of carp (Carassius auratus) Vitellogenin (Vtg). The sensor was fabricated based on screen-printed carbon arrays (SPCAs) containing eight carbon working and an integrated carbon counter electrodes. To construct the sensor, a conducting polymer (poly-terthiophene carboxylic acid) was electropolymerized on the surface of working electrodes and the polymer-coated SPCAs was characterized by SEM.

View Article and Find Full Text PDF

To develop a general method for the detection of histidine-tagged proteins, the interactions of the histidine epitope tag of MutH and MutL proteins with the epitope specific monoclonal anti-His6 antibody were monitored by a label-free direct method using impedance spectroscopy. The immunosensor was fabricated by covalent coupling of the antibody on a conducting polymer coated electrode surface. The impedance of the antibody modified electrode was decreased after binding to the histidine-tagged proteins.

View Article and Find Full Text PDF

A simple and direct immunosensor for the determination of carp (Carassius auratus) vitellogenin (Vtg), a female-specific protein, has been proposed based on an antibody-captured conducting polymer-coated electrode. The monoclonal antibody specific to carp (C. auratus) Vtg was immobilized by covalent coupling to the carboxylic acid group on the polymer.

View Article and Find Full Text PDF

A disposable and mediatorless immunosensor based on a conducting polymer (5,2':5'2"-terthiophene-3'-carboxylic acid) coated screen-printed carbon electrode has been developed using a separation-free homogeneous technique for the detection of rabbit IgG as a model analyte. Horseradish peroxidase (HRP) and streptavidin were covalently bonded with the polymer on the electrode and biotinylated antibody was immobilized on the electrode surface using avidin-biotin coupling. This sensor was based on the competitive assay between free and labeled antigen for the available binding sites of antibody.

View Article and Find Full Text PDF