Thermal Magnetic Resonance (ThermalMR) integrates Magnetic Resonance Imaging (MRI) diagnostics and targeted radio-frequency (RF) heating in a single theranostic device. The requirements for MRI (magnetic field) and targeted RF heating (electric field) govern the design of ThermalMR applicators. We hypothesize that helmet RF applicators (HPA) improve the efficacy of ThermalMR of brain tumors versus an annular phased RF array (APA).
View Article and Find Full Text PDFMultifunctional wound dressings based on hydrogels are an efficacious and practicable strategy in therapeutic processes and accelerated chronic wound healing. Here, copper (Cu) nanoparticles were added to chitosan/sodium alginate (CS/SA) hydrogels to improve the antibacterial properties of the prepared wound dressings. Due to the super-hydrophobicity of Cu nanoparticles, polyethylene glycol (PEG) was used as a surfactant, and then added to the CS/SA-based hydrogels.
View Article and Find Full Text PDFKey Clinical Message: Muscular and subcutaneous candidiasis is a rare entity in immunocompromised patients, but it should be kept in mind when we see multiple cystic soft tissue masses in addition to target-shaped hepatosplenic lesions in neutropenic patients. US and MRI are useful imaging modalities for the diagnosis and follow-up of these patients.
Abstract: Soft tissue candidiasis is an opportunistic infection in immunocompromised patients and must always be diagnosed and treated as soon as possible.
Cerebral gliomatosis (GC) is a rare diffuse infiltrative growth pattern of glioma with nonspecific clinical manifestations like visual impairment that may involve bilateral temporal lobes. Herpes simplex encephalitis (HSE) and limbic encephalitis (LE) can also lead to temporal lobe involvement. Differentiating these entities is necessary for patients with misleading presentations and imaging findings.
View Article and Find Full Text PDFIn this study, a new electrochemical sensor was designed based on a hybrid of polyamide (PA) and chromotropic acid (CA) nanofibers electrospun on a glassy carbon electrode (GCE) configured as PANFs-CANFs/GCE. The electrochemical response of this sensor showed an excellent electrochemical activity for the detection of Hg ions using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. The proposed sensor exhibited the prominent electrocatalytic value of (α = 0.
View Article and Find Full Text PDFBackground: Recent case reports and small studies have reported activation of the magnet-sensitive switches in cardiovascular implantable electronic devices (CIEDs) by the new iPhone 12 series, initiating asynchronous pacing in pacemakers and suspension of antitachycardia therapies in implantable cardioverter-defibrillators (ICDs).
Objective: The purpose of this prospective single-center observational study was to quantify the risk of magnetic field interactions of the iPhone 12 with CIEDs.
Methods: A representative model of each CIED series from all manufacturers was tested ex vivo.
Considering the significance of mycotoxin detection in food industries, herein, an ultrasensitive aptasensor was developed based on aflatoxin B1 aptamer immobilized on Carbon quantum dots/octahedral CuO nanocomposite. Electrochemical measurements were based on Electrochemical Impedance Spectroscopy (EIS) and Differential Pulse Voltammetry (DPV). Since the effective parameters (pH, temperature, incubation time and concentration of aptamers) are interdependent, so their dependent study can be nonideal.
View Article and Find Full Text PDF