Publications by authors named "Fadia H Metwally"

Four different stability-indicating procedures are described for determination of tiapride in pure form, dosage form, and human plasma. Second derivative (D2), first derivative of ratio spectra (1DD), spectrofluorimetric, and high-performance column liquid chromatographic (LC) methods are proposed for determination of tiapride in presence of its acid-induced degradation products, namely 2-methoxy-5-(methylsulfonyl) benzoic acid and 2-diethylaminoethylamine. These approaches were successfully applied to quantify tiapride using the information included in the absorption, excitation, and emission spectra of the appropriate solutions.

View Article and Find Full Text PDF

The construction and electrochemical response characteristics of polyvinyl chloride (PVC) membrane sensors for determination of tiapride in presence of its degradation products are described. The sensors are based on the ion association complexes of tiapride cation with sodium tetraphenyl borate (Tia-TPB) [sensor 1]) or ammonium reineckate (Tia-R) [sensor 2] counter anions as ion exchange sites in PVC matrix. The performance characteristics, sensitivity and selectivity of these electrodes in presence of tiapride degradation products were evaluated according to IUPAC recommendations.

View Article and Find Full Text PDF

The quantitative predictive abilities of the new and simple bivariate spectrophotometric method are compared with the results obtained by the use of multivariate calibration methods [the classical least squares (CLS), principle component regression (PCR) and partial least squares (PLS)], using the information contained in the absorption spectra of the appropriate solutions. Mixtures of the two drugs Nifuroxazide (NIF) and Drotaverine hydrochloride (DRO) were resolved by application of the bivariate method. The different chemometric approaches were applied also with previous optimization of the calibration matrix, as they are useful in simultaneous inclusion of many spectral wavelengths.

View Article and Find Full Text PDF

New selective, precise, and accurate methods are described for the determination of a ternary mixture containing drotaverine hydrochloride (I), caffeine (II), and paracetamol (III). The first method uses the first (D1) and third (D3) derivative spectrophotometry at 331 and 315 nm for the determination of (I) and (III), respectively, without interference from (II). The second method depends on the simultaneous use of the first derivative of the ratio spectra (DD1) with measurement at 312.

View Article and Find Full Text PDF

Three new, simple, sensitive, and accurate stability-indicating methods were developed for quantitative determination of bisacodyl in the presence of its degradation products, monoacetyl bisacodyl (I) and desacetyl bisacodyl (II), in enteric coated tablets, suppositories, and raw material. The first is a spectrodensitometric method in which the drug is separated from I and II on silica gel plates using chloroform-acetone (9 + 1, v/v) as the mobile phase with ultraviolet detection of the separated bands at 223 nm over a concentration range of 0.2-1.

View Article and Find Full Text PDF

A binary mixture of hyoscine butylbromide and ketoprofen was determined by 4 different methods. The first involved determination of hyoscine butylbromide and ketoprofen using the ratio-spectra first-derivative spectrophotometric technique at 211 and 234 nm over the concentration ranges of 2-14 and 5-45 microg/mL with mean accuracies 99.84 +/-0.

View Article and Find Full Text PDF

Spectrophotometric, spectrodensitometric and HPLC are stability indicating methods described for determination of Zaleplon in pure and dosage forms. As Zaleplon is easily degradable, the proposed techniques in this manuscript are adopted for its determination in presence of its alkaline degradation product, namely N-[4-(3-cyano-pyrazolo[1,5a]pyridin-7-yl)-phenyl]-N-ethyl-acetamide. These approaches are successfully applied to quantify Zaleplon using the information included in the absorption spectra of appropriate solutions.

View Article and Find Full Text PDF

Four new methods were developed and validated for the determination of cinnarizine HCl in its binary mixture with piracetam in pure and pharmaceutical preparations. The first one was a densitometric analysis that provides a simple and rapid method for the separation and quantification of cinnarizine HCI. The method depends on the quantitative densitometric evaluation of thin-layer chromatograms of cinnarizine HCI at 252 nm over concentration range of 1-6 microg/spot, with a mean accuracy of 100.

View Article and Find Full Text PDF

A rapid, simple, and selective method was developed for the determination of etodolac. The method depends on complexation of etodolac with copper (II) acetate and iron (III) chloride followed by extraction of complexes with dichloromethane and then measuring the extracted complexes spectrophotometrically at 684 and 385 nm in case of Cu (II) or Fe (III), respectively. Different factors affecting the reaction, such as pH, reagent concentration, and time, were studied.

View Article and Find Full Text PDF

Three new, different, simple, sensitive, and accurate methods were developed for quantitative determination of nifuroxazide (I) and drotaverine hydrochloride (II) in a binary mixture. The first method was spectrophotometry, which allowed determination of I in the presence of II using a zero-order spectrum with an analytically useful maximum at 364.5 nm that obeyed Beer's law over a concentration range of 2-10 microg/mL with mean percentage recovery of 100.

View Article and Find Full Text PDF

A binary mixture of terbinafine hydrochloride and triamcinolone acetonide was determined by three different methods. The first one concerned with determination of both drugs using first derivative (D(1)) spectrophotometric technique at 297 and 274 nm over concentration ranges of 5-30 and 4-24 microg ml(-1), with mean percentage accuracies 99.90+/-0.

View Article and Find Full Text PDF