Aim of a low radon cleanroom technology is to minimize at the same time radon, radon decay products concentration and aerosol concentration and to minimize deposition of radon decay products on the surfaces. The technology placed in a deep underground laboratory such as LSM Modane with suppressed muon flux and shielded against external gamma radiation and neutrons provides "Zero dose" space for basic research in radiobiology (validity of the LNT hypothesis for very low doses) and for the fabrication of nanoelectronic circuits to avoid undesirable "single event effects." Two prototypes of a low radon cleanroom were built with the aim to achieve radon concentration lower than 100 mBq·m in an interior space where only radon-free air is delivered into the cleanroom technology from a radon trapping facility.