Publications by authors named "Fabio Lissoni"

We present the case of an 82-year-old woman with history of bivalvular replacement (mitral mechanical prothesis and tricuspid bioprothesis) and subsequent tricuspid percutaneous valve-in-valve bioprothesis implantation. The patient developed an indication for pacemaker implantation. We describe the feasibility of leadless pacemaker implantation across the tricuspid prothesis when all other techniques fail.

View Article and Find Full Text PDF

Introduction: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds).

Methods And Results: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort.

View Article and Find Full Text PDF

Background: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood.

Objectives: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS).

Methods: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds).

View Article and Find Full Text PDF

Background: Parameters measured during implantable cardioverter defibrillator (ICD) implant also depend on bioelectrical properties of the myocardium. We aimed to explore their potential association with clinical outcomes in patients with single/dual-chamber ICD and cardiac resynchronization therapy defibrillator (CRT-D).

Methods: In the framework of the Home Monitoring Expert Alliance, baseline electrical parameters for all implanted leads were compared by the occurrence of all-cause mortality, adjudicated ventricular arrhythmia (VA), and atrial high-rate episode lasting ≥24 hours (24 h AHRE).

View Article and Find Full Text PDF

Background: The role of atrial rate-responsive (RR) pacing in cardiac resynchronization therapy (CRT) is unclear due to the favorable effect of rate lowering in systolic heart failure. Atrial high rate episodes (AHREs) in CRT recipients are particularly worrisome since they cause loss of CRT, beyond representing a stroke risk factor.

Hypothesis: The presence of an association between RR and the incidence of AHREs.

View Article and Find Full Text PDF

Aim: Ventricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry.

Methods And Results: A total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres.

View Article and Find Full Text PDF

Aims: Some barriers seem to exist in changing implantable cardioverter defibrillator (ICD) manufacturer at the time of device replacement. We sought to understand the obstacles to changing ICD manufacturer within the cohort of patients enrolled in the Detect Long-term Complications After ICD Replacement Registry.

Methods: We analyzed 784 consecutive ICD/cardiac resynchronization therapy defibrillator (CRT-D) device replacements within a 1.

View Article and Find Full Text PDF

Epidemiological data show an even greater prevalence of heart failure in the general population, in particular in elderly people, both in Italy and the other European countries. Patients admitted to hospital because of heart failure are commonly complex patients with relevant comorbidities and frequent readmissions. Hospital care accounts largely for the costs due to heart failure, whereas expenditure for therapies (drugs, devices and surgery) is less significant; non-medical and social costs represent also a relevant part of total costs.

View Article and Find Full Text PDF