Publications by authors named "Fabienne Taillieu"

Background And Purpose: Alignment of the glenoid component with the scapula during total shoulder arthroplasty (TSA) is challenging due to glenoid erosion and lack of both bone stock and guiding landmarks. We determined the extent to which the implant position is governed by the preoperative erosion of the glenoid. Also, we investigated whether excessive erosion of the glenoid is associated with perforation of the glenoid vault.

View Article and Find Full Text PDF

Background: Current techniques for measuring in vivo polyethylene wear suffer from a range of problems, resulting in an unacceptable lack of repeatability and/or insufficient accuracy when they are used to measure the low wear rates associated with new, highly crosslinked polyethylene. We describe an improved CT method for measurement of 3D femoral head penetration in PE acetabular cups that has sufficient accuracy and repeatability to allow assessment of the wear potential of modern implants.

Method: The accuracy and repeatability of the CT-scan method was determined by blindly repeating measurements on a precisely calibrated 28-mm prosthetic head and by comparing them with direct metrological measurements on 10 acetabular specimens with in vitro wear from machining, and on 8 explanted acetabular specimens with in vivo wear.

View Article and Find Full Text PDF

Glenoid fixation failure has only been grossly characterized. This lack of information hinders attempts to improve fixation because of a lack of methodologies for detecting and monitoring fixation failure. Our goal was twofold: to collect detailed data of glenoid fixation fracture, and to investigate computed tomography (CT)-scanning as a tool for investigations of fixation failure.

View Article and Find Full Text PDF

Despite the curvaceous profile of the acetabulum, orthopaedic surgeons have continued to implant hemispheric cups since the introduction of total hip arthroplasty. The geometric discrepancies between the natural acetabulum and implant can result in painful iliopsoas impingement attributable to prosthetic overlap at the anterior acetabular ridge over which the iliopsoas tendon extends to leave the pelvis. We expanded on previous in vitro observations of acetabular morphology using a large in vivo sample and quantified the dimensions of the psoas valley.

View Article and Find Full Text PDF

Purpose: To assess placental perfusion and permeability in mice with magnetic resonance (MR) imaging.

Materials And Methods: This study was conducted according to French law and National Institutes of Health recommendations for animal care. Twenty-two pregnant BALB/c mice were examined at 1.

View Article and Find Full Text PDF