This work presents an adaptive sensor signal-processing approach to enable quantification, using a single gas sensor or a small sensor array, of multianalyte mixtures of aromatic hydrocarbons in the presence of various interferents and humidity for environmental-monitoring applications. Dynamic sensor responses are analyzed by extracting multivariable sensing parameters to provide necessary sensitivity and selectivity. This is achieved by integrating the Levenberg-Marquardt-modified, exponentially weighted, recursive-least-squares-estimation (LM-modified EW-RLSE) algorithm and principal-component analysis (PCA).
View Article and Find Full Text PDFThe isomer-specific detection and quantitation of -, -, and -xylene and ethylbenzene, dissolved singly and as mixtures in aqueous solutions at concentrations from 100 to 1200 ppb by volume, is reported for a specifically designed polymer-plasticizer coating on a shear-horizontal surface acoustic wave (SH-SAW) device. The polystyrene-ditridecyl phthalate-blend coating was designed utilizing Hansen solubility parameters and considering the dipole moment and polarizability of the analytical targets and coating components to optimize the affinity of the sensor coating for the four chemical isomers. The two key coating sorption properties, sensitivity and response time constant, are determined by the (slightly different) dipole moments and polarizabilities of the four target analytes: as analyte dipole moment decreases, coating sensitivity increases; as analyte polarizability decreases, coating response time lengthens.
View Article and Find Full Text PDFA relatively simple design procedure is presented for new, adaptable chemical sensor coatings made from a single polymerplasticizer pair to detect single or a mixture of chemical compounds (e.g., BTEX, the small aromatic hydrocarbon family).
View Article and Find Full Text PDFThermally excited and piezoresistively detected in-plane cantilever resonators have been previously demonstrated for gas- and liquid-phase chemical and biosensing applications. In this work, the hammerhead resonator geometry, consisting of a cantilever beam supporting a wider semicircular "head", vibrating in an in-plane vibration mode, is shown to be particularly effective for gas-phase sensing with estimated limits of detection in the sub-ppm range for volatile organic compounds. This paper discusses the hammerhead resonator design and the particular advantages of the hammerhead geometry, while also presenting mechanical characterization, optical characterization, and chemical sensing results.
View Article and Find Full Text PDFMost chemical sensors are only partially selective to any specific target analyte(s), making identification and quantification of analyte mixtures challenging, a problem often addressed using arrays of partially selective sensors. This work presents and experimentally verifies a signal-processing technique based on estimation theory for online identification and quantification of multiple analytes using only the response data collected from a single polymer-coated sensor device. The demonstrated technique, based on multiple stages of exponentially weighted recursive least-squares estimation (EW-RLSE), first determines which of the analytes included in the sensor response model are absent from the mixture being analyzed; these are then eliminated from the model prior to executing the final stage of EW-RLSE, in which the sample's constituent analytes are more accurately quantified.
View Article and Find Full Text PDFA new approach is reported to detect and quantify the members of a group of small-aromatic-molecule target analytes: benzene, toluene, ethylbenzene, and xylenes (BTEX), dissolved in water, in the presence of interferents, using only the data collected from a single polymer-coated SH-SAW (shear horizontal surface acoustic wave) device and a two-stage adaptive estimation scheme. This technique is composed of exponentially weighted recursive least-squares estimation (EW-RLSE) and a bank of Kalman filters (BKFs) and does not require any prior knowledge of the initial concentration range of the target analytes. The proposed approach utilizes the transient sensor response to sorption and/or desorption of the analytes as well as the error range associated with the response time constants to provide more information about the analyte-specific interactions with the polymer film.
View Article and Find Full Text PDFWe report the first-ever direct detection of benzene in water at concentrations below 100 ppb (parts per billion) using acoustic wave (specifically, shear-horizontal surface acoustic wave, SH-SAW) sensors with plasticized polymer coatings. Two polymers and two plasticizers were studied as materials for sensor coatings. For each polymer-plasticizer combination, the influence of the mixing ratio of the blend on the sensitivity to benzene was measured and compared to commercially available polymers that were used for BTEX (benzene, toluene, ethylbenzene, and xylene) detection in previous work.
View Article and Find Full Text PDFThe present work investigates a compact sensor system that provides rapid, real-time, in situ measurements of the identities and concentrations of aromatic hydrocarbons at parts-per-billion concentrations in water through the combined use of kinetic and thermodynamic response parameters. The system uses shear-horizontal surface acoustic wave (SH-SAW) sensors operating directly in the liquid phase. The 103 MHz SAW sensors are coated with thin sorbent polymer films to provide the appropriate limits of detection as well as partial selectivity for the analytes of interest, the BTEX compounds (benzene, toluene, ethylbenzene, and xylenes), which are common indicators of fuel and oil accidental releases in groundwater.
View Article and Find Full Text PDFA need exists for compact sensor systems capable of in situ monitoring of groundwater for accidental releases of fuel and oil. The work reported here addresses this need, using shear horizontal surface acoustic wave (SH-SAW) sensors, which function effectively in liquid environments. To achieve enhanced sensitivity and partial selectivity for hydrocarbons, the devices are coated with thin chemically sensitive polymer films.
View Article and Find Full Text PDFDirect growth of a suspended single nanostructure (SSN) at a specific location is presented. The SSN is grown across a metallic nanoscale gap by migration in air at room temperature. The nanogap is fabricated by industrial standard optical lithography and anisotropic wet chemical silicon etching.
View Article and Find Full Text PDFExpressions describing the resonant frequency and quality factor of a dynamically driven, polymer-coated microcantilever in a viscous liquid medium have been obtained. These generalized formulas are used to describe the effects the operational medium and the viscoelastic coating have on the device sensitivity when used in liquid-phase chemical sensing applications. Shifts in the resonant frequency are normally assumed proportional to the mass of sorbed analyte in the sensing layer.
View Article and Find Full Text PDFA novel resonant cantilever sensor system for liquid-phase applications is presented. The monolithic system consists of an array of four electromagnetically actuated cantilevers with transistor-based readout, an analog feedback circuit, and a digital interface. The biochemical sensor chip with a size of 3 mm x 4.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
November 2006
Microcantilevers coated with a chemically sensitive layer are increasingly being used in chemical detection systems. The sensitive coating, often a polymer, absorbs specific molecules, which can be detected by monitoring the shift in the mechanical resonant frequency. Usually, the frequency shift resulting from molecular absorption is interpreted as a mass loading effect.
View Article and Find Full Text PDFDirect chemical sensing in liquid environments using polymer-guided shear horizontal surface acoustic wave sensor platforms on 36 degrees rotated Y-cut LiTaO3 is investigated. Design considerations for optimizing these devices for liquid-phase detection are systematically explored. Two different sensor geometries are experimentally and theoretically analyzed.
View Article and Find Full Text PDF