Background: Implantable cardioverter defibrillators (ICD) prevent sudden cardiac death (SCD). Patients with end-stage renal disease (ESRD) requiring dialysis are at a very high risk of infection from cardiac implantable electronic device (CIED) implantation as well as mortality. In the present study, we compared the long-term complications and outcomes between subcutaneous ICD (S-ICD) and transvenous ICD (TV-ICD) recipients.
View Article and Find Full Text PDFFront Cardiovasc Med
July 2024
Background And Aims: Wearable cardioverter defibrillator (WCD) can protect patients from sudden cardiac death due to ventricular tachyarrhythmias and serve as a bridge to decision of definite defibrillator implantation. The aim of this analysis from an international, multicenter WCD registry was to identify predictors of sustained ventricular tachycardia (VT) and/or ventricular fibrillation (VF) in this population.
Methods: One thousand six hundred seventy-five patients with WCD were included in a multicenter registry from 9 European centers, with a median follow-up of 440 days (IQR 120-893).
Introduction: Coronary sclerosis is a risk factor for the progression to obstructive coronary artery disease (CAD). However, understanding its impact on the outcomes of patients with myocardial infarction and non-obstructive coronary arteries is limited. This study aimed to explore the prognostic influence of coronary sclerosis on in- and out-of-hospital events in troponin-positive patients with non-obstructive coronary arteries.
View Article and Find Full Text PDFBackground: Cephalic vein cutdown (CVC) and subclavian vein puncture (SVP) are the most commonly used access sites for transvenous lead placement of cardiac implantable electronic devices (CIEDs). Limited knowledge exists about the long-term patency of the vascular lumen housing the leads.
Methods: Among the 2703 patients who underwent CIED procedures between 2005 and 2013, we evaluated the phlebographies of 162 patients scheduled for an elective CIED replacement (median of 6.
Background: The aim of the present study was to evaluate the long-term safety and effectiveness of the subcutaneous implantable cardioverter defibrillator (S-ICD) when implanted intermuscularly in patients with end-stage renal disease and hemodialysis.
Methods: This study is a retrospective analysis of 21 consecutive patients implanted with S-ICDs at three experienced centers in Germany with comorbid renal insufficiency requiring hemodialysis, as well as being at risk of sudden cardiac death. The S-ICD was placed intermuscularly in all patients.
There is a rising number in complications associated with more cardiac electrical devices implanted (CIED). Infection and lead dysfunction are reasons to perform transvenous lead extraction. An ideal anaesthetic approach has not been described yet.
View Article and Find Full Text PDFBackground: Infection, lead dysfunction and system upgrades are all reasons that transvenous lead extraction is being performed more frequently. Many centres focus on a single method for lead extraction, which can lead to either lower success rates or higher rates of major complications. We report our experience with a systematic approach from a less invasive to a more invasive strategy without the use of laser sheaths.
View Article and Find Full Text PDFBackground: The wearable cardioverter defibrillator (WCD), (LifeVest, ZOLL, Pittsburgh, PA, USA) is a medical device designed for the temporary detection and treatment of malignant ventricular tachyarrhythmias. WCD telemonitoring features enable the evaluation of the physical activity (PhA) of the patients. We sought to assess with the WCD the PhA of patients with newly diagnosed heart failure.
View Article and Find Full Text PDFThe relationship between thyroid function and cardiac disease is complex. Both hypothyroidism and thyrotoxicosis can predispose to ventricular arrhythmia and other major adverse cardiovascular events (MACE), so that a U-shaped relationship between thyroid signaling and the incidence of MACE has been postulated. Moreover, recently published data suggest an association between thyroid hormone concentration and the risk of sudden cardiac death (SCD) even in euthyroid populations with high-normal FT4 levels.
View Article and Find Full Text PDFBipolar active fixation (BipolarAFL) and quadripolar passive fixation left-ventricular leads (QuadPFL) have been designed to reduce the risk of phrenic nerve stimulation (PNS), enable targeted left-ventricular pacing, and overcome problems of difficult coronary venous anatomy and lead dislodgment. This study sought to report the long-term safety and performance of a BipolarAFL, Medtronic Attain Stability 20066, compared to QuadPFL. We performed a single-operator retrospective analysis of 81 patients receiving cardiac resynchronization therapy (CRT) (36 BipolarAFL, 45 QuadPFL).
View Article and Find Full Text PDFBackground: Optimization of cardiac resynchronization therapy (CRT) is often time-consuming and therefore underused in a clinical setting. Novel device-based algorithms aiming to simplify optimization include a dynamic atrioventricular delay (AVD) algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott). This study examines the acute effect of SyncAV and MPP on electrical synchrony in patients with newly and chronically implanted CRT devices.
View Article and Find Full Text PDFNutr Metab Cardiovasc Dis
March 2021
Background And Aims: Oral anticoagulation is effective for stroke prevention in atrial fibrillation (AF). However, strokes may still occur in high-risk individuals. We conducted a prospective trial to assess the association between adipocytokine serum levels and surrogate parameters for thromboembolic events.
View Article and Find Full Text PDFBackground: The prevalence of aortic valve stenosis is increasing due to the continuously growing geriatric population. Data on procedural success and mortality of very old patients are sparse, raising the question of when this population may be deemed as "too old even for transcatheter aortic valve replacement (TAVR)." We, therefore, sought to evaluate the influence of age on outcome after TAVR and the impact of direct implantation.
View Article and Find Full Text PDFBackground: Current recommendations for valve size selection are based on multidimensional annular measurements, yet the overlap between two different transcatheter heart valve (THV) sizes remains. We sought to evaluate whether undersizing but overfilling eliminates the gray zones of valve sizing.
Methods: Data of 246 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with the balloon-expandable bioprosthesis with either conventional sizing and nominal filling (group 1 (NF-TAVR), n = 154) or undersizing but overfilling under a Less Is More (LIM)-Principle (group 2 (LIM-TAVR), n = 92) were compared.
Herzschrittmacherther Elektrophysiol
March 2020
Malfunctions in implanted pacemaker and defibrillator systems can affect all components of the device (battery, capacitor, central processing unit (CPU), connector, soldering points, electrodes). The resulting problems can manifest themselves as inadequate therapy, a lack of therapy despite the need for stimulation or shock release in case of ventricular tachyarrhythmia, or as an ineffective delivery of therapy. The high number of implanted pacemaker and defibrillator systems, the increased life expectancy and the technical progress of cardiac "device" therapy mean that the treating physician is confronted with increasingly complex problems in the follow-up.
View Article and Find Full Text PDFBackground: Multipoint pacing [Multipoint™ Pacing (MPP), Abbott] via a single left ventricular lead (Quartet™ LV lead, Abbott) improves acute left ventricular (LV) function and response to cardiac resynchronization therapy (CRT). Aim of this study was to examine additional benefits in terms of LV reverse remodeling and CRT response by activating MPP in responders and non-responders to conventional biventricular pacing (CONV).
Methods: 43 consecutive patients receiving CRT (Quadra Assura MP™, Abbott) received LV dP/dt optimized CONV programming for 6 months.
Background: Controversy exists about the pathophysiology of different hemodynamic subgroups of AS. In particular, the mechanism of the paradoxical low-flow, low-gradient (PLFLG) AS with preserved ejection fraction (EF) is unclear.
Methods: A total of 41 patients with severe, symptomatic AS were divided into the following 4 subgroups based on the echocardiographically determined hemodynamics: (1) normal-flow, high-gradient (NFHG) AS; (2) low-flow, high-gradient AS; (3) paradoxical low-flow, low-gradient (PLFLG) AS with preserved EF and (4) low-flow, low-gradient (LFLG) AS with reduced EF.
Aims: Cardiac Contractility Modulation (CCM) is a treatment for heart failure based on electrical signals applied during the absolute refractory period. CCM improves myocardial molecular and biochemical characteristics of heart failure and improves exercise tolerance and quality of life. However, the long term impact on survival has not been described.
View Article and Find Full Text PDFBackground: Cardiac contractility modulation (CCM) signals are non-excitatory electrical signals delivered during the absolute refractory period intended to improve contraction and cardiac function. Clinical trials have shown that CCM treatment significantly improves exercise tolerance and quality of life in symptomatic heart failure patients. Studies with CCM therapy typically include CCM delivery for 3, 5 or 7 h per day, although other configurations are also commonly used.
View Article and Find Full Text PDFBackground: Although hyperthyroidism predisposes to atrial fibrillation, previous trials have suggested decreased triiodothyronine (T3) concentrations to be associated with postoperative atrial fibrillation (POAF). Therapy with thyroid hormones (TH), however, did not reduce the risk of POAF. This study reevaluates the relation between thyroid hormone status, atrial electromechanical function and POAF.
View Article and Find Full Text PDFBackground: Recent studies have suggested a strong association between obstructive sleep apnoea (OSA) and atrial fibrillation (AF). However, the impact of continuous positive airway pressure (CPAP) therapy on reverse atrial remodelling in patients with OSA is poorly understood. We aimed to determine the impact of CPAP therapy on total atrial conduction time measured by PA tissue Doppler imaging (TDI) interval in patients without history of AF.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
October 2015
Background: Silent cerebral events (SCE) have been identified on cerebral diffusion-weighted cerebral magnetic resonance imaging (DE-MRI) after catheter ablation (CA) of atrial fibrillation (AF). The purpose of this study was to investigate the impact of atrial remodeling on the incidence of SCE after AF CA.
Methods: Forty patients (67.
Background: A key mechanism of atrial fibrillation (AF) is atrial remodeling. Total atrial conduction time non-invasively assessed via tissue Doppler imaging (PA-TDI interval) may reflect the degree of electrical and structural atrial remodeling. The purpose of this study was to determine whether the PA-TDI interval is an independent predictor of recurrent AF after successful electrical cardioversion (eCV) and if it suggests reverse atrial remodeling.
View Article and Find Full Text PDF