Publications by authors named "Fabian QueiSSert"

: Male stress urinary incontinence (SUI) after surgical treatment of benign prostatic enlargement (BPE) is an infrequent but dreadful complication and constitutes a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is rather unknown, mainly due to the rarity of this condition. We aimed to assess the results of ATOMS to treat SUI after transurethral resection (TURP) or holmium laser enucleation (HoLEP) of the prostate.

View Article and Find Full Text PDF

Background: Uroflowmetry (UF) is an established procedure in urology and is recommended before further investigations of neurogenic lower urinary tract dysfunction (NLUTD). Some authors even consider using UF instead of urodynamics (UD). Studies on the interrater reliability of UF regarding treatment recommendations are rare, and there are no relevant data on people with multiple sclerosis (PwMS).

View Article and Find Full Text PDF

Low compliance is not an independent disease but a severe manifestation resulting from various disorders of the storage and excretory function of the bladder. Reduced distensibility of the detrusor muscle can lead to a pressure load on the upper urinary tract but also to urge-dominant LUTS and urinary tract infections. Neurogenic causes, especially spinal cord injury/spina bifida but also iatrogenic damage or subvesical obstruction, can contribute to the development.

View Article and Find Full Text PDF

Objectives: This study aimed to compare the effectiveness and safety of the adjustable trans-obturator male system (ATOMS®) to treat post-prostatectomy incontinence (PPI) in radiated patients compared with non-radiated patients, using propensity score-matching analysis to enhance the validity of the comparison.

Patients And Methods: Consecutive men with PPI treated with silicone-covered scrotal port ATOMS (A.M.

View Article and Find Full Text PDF

In addition to the classical neurourological diseases multiple sclerosis and paraplegia/spina bifida, there are many and also widely spread diseases of the neurological spectrum that can result in significant dysfunctions of the urinary tract. Depending on the location (cerebral/suprapontine, spinal/suprasacral, spinal infrasacral and peripheral), different disorders can result (detrusor overactivity and underactivity, sphincter dyssynergia and low compliance). Changes can also occur over the course of an illness and thus make the analysis of the respective disorder even more difficult.

View Article and Find Full Text PDF

(1) Background: Treatment of male stress incontinence in patients with prostate cancer treated with radical prostatectomy and adjuvant pelvic radiation is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is not well established, despite the general belief that outcomes are worse than in patients without radiation. (2) Methods: Retrospective multicenter study evaluating patients treated with silicone-covered scrotal port (SSP) ATOMS implant after radical prostatectomy and radiotherapy in nine different institutions between 2016 and 2022.

View Article and Find Full Text PDF

Background: Adjustable sling ATOMS-SSP results in ventral compression of the urethra with favorable results in the treatment of men with mild to moderate stress incontinence. However, with transobturator tunneling and mesh fixation, the surgeon has a range of options, which leads to different results and sometimes unfavorable positioning of the silicone cushion. Using retrograde urethrography (RUG), we identified ATOMS patients with considerable misplacement.

View Article and Find Full Text PDF

Background: Circular urethral compression with an artificial sphincter allows control of voiding, even in patients with severe stress urinary incontinence, but it heightens the risk of urethral atrophy and erosion. This study of one of the largest populations of patients treated with radiotherapy investigates the additive effect of the post-radiogenic stricture of the membranous urethra/bladder neck on AMS 800 artificial urinary sphincter outcomes.

Methods: In a retrospective multicenter cohort study, we analyzed patients fitted with an AMS 800, comparing those who had received radiotherapy with patients presenting a devastated bladder outlet (stricture of the membranous urethra/bladder neck).

View Article and Find Full Text PDF

(1) Background: Male stress incontinence in patients with previously treated urethral or bladder neck stricture is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is unknown. (2) Methods: All patients with primary ATOMS implants in our institution between 2014 and 2021 were included.

View Article and Find Full Text PDF

Introduction And Hypothesis: This study analyzes the long-term results of supratrigonal cystectomy and augmentation cystoplasty in patients with severe ulcerative interstitial cystitis/bladder pain syndrome (IC/BPS) and reduced bladder capacity.

Methods: Outcome data were retrospectively and prospectively collected and analyzed in women who underwent supratrigonal cystectomy and augmentation cystoplasty for ulcerative IC/BPS at Muenster University Hospital between 1991 and 2006. We used cross-tabulation and Pearson's Chi-squared test to examine how outcome is influenced by age, preoperative functional bladder volume, and choice of augmentation material.

View Article and Find Full Text PDF

(1) Background: This study examined outcomes of second-line ATOMS implantation after failure of the fixed male sling (FMS) AdVance/AdVance XP. (2) Methods: A retrospective multicenter cohort analysis was carried out in men implanted with an ATOMS between 2011 and 2020 after failure of an AdVance/AdVance XP. Success was assessed on the basis of objective (dryness, 0-1 pad/24 h or >20 g/24 h pad test) and subjective results (PGI-I).

View Article and Find Full Text PDF

Objective: To assess changes in voiding phase, especially urethral resistance after post-prostatectomy urinary incontinence (PPI) treatment with the Adjustable TransObturator Male System (ATOMS).

Material And Methods: A longitudinal prospective study was performed on 45 men treated with ATOMS for PPI, with the intention to evaluate the changes produced by the implant on the voiding phase. Patients with preoperative urodynamic study were offered postoperative urodynamic evaluation, and both studies were compared.

View Article and Find Full Text PDF

Introduction: This analysis, based on pre- and postoperative urodynamic data, is the first to elucidate the influence of the Adjustable Transobturator Male System (ATOMS, A.M.I.

View Article and Find Full Text PDF

Objective: To evaluate the clinical profile and the organisms producing adjustable transobturator male system (ATOMS) infection in a contemporary series.

Methods: Multicenter retrospective study evaluating patients undergoing ATOMS explant for clinical signs of infection from a series of 902 patients treated in 9 academic institutions. Clinical and microbiological data were evaluated.

View Article and Find Full Text PDF

Aim: To evaluate treatment options after surgical revision of adjustable transobturator male system (ATOMS) and the results of further incontinence implantation.

Materials And Methods: A retrospective multicenter study evaluating patients with surgical revision of ATOMS in academic institutions. Causes and factors affecting revision-free interval were studied and also the frequency of device explant and placement of second ATOMS or artificial urinary sphincter (AUS) at surgeon discretion.

View Article and Find Full Text PDF

Objective: To analyze decision-making in patients with male urinary incontinence (SUI) in centers of expertise. The artificial urinary sphincter (AUS) remains the gold standard for male patients with moderate to severe SUI but adjustable male slings are a minimally invasive treatment option with good results, hence without a high level of evidence regarding the optimal patient selection.

Materials And Methods: In total, 220 patients (88 AUS; 132 adjustable slings) were investigated from the DOMINO database that underwent surgery between 2010 and 2012 in 5 urological departments that offer adjustable sling systems as well as AUS systems for patients with moderate to severe urinary incontinence.

View Article and Find Full Text PDF

Background: Fixed and adjustable male slings for the treatment of male urinary stress incontinence became increasingly popular during the last decade. Although fixed slings are recommended for the treatment of mild to moderate stress urinary incontinence, there is still a lack of evidence regarding the precise indication for an adjustable male sling. Furthermore, there is still no evidence that one type of male sling is superior to another.

View Article and Find Full Text PDF

Aim: To analyze the influence of implantation volume of artificial sphincters (AMS 800) on outcome in a large central European multicenter cohort study.

Methods: As part of the DOMINO (Debates on Male Incontinence) project, the surgical procedures and outcomes were retrospectively analyzed in a total of 473 patients who received an artificial sphincter (AMS 800) between 2010 and 2012. Clinics that implanted at least 10 AMS 800 per year were defined as high-volume centers.

View Article and Find Full Text PDF

Objective: The artificial urinary sphincter (AUS) is the surgical gold standard after previously failed surgical treatment for male urinary stress incontinence. The evidence for a male sling as salvage treatment is poor, but there is a proportion of patients that refuse implantation of an AUS or have a relative contraindication. The goal of our retrospective study was an analysis of outcome and complications of patients with a secondary sling after previously failed surgery for stress urinary incontinence (SUI).

View Article and Find Full Text PDF

Objective: To evaluate whether urodynamic voiding risk factors can be predictive of failure of postprostatectomy urinary incontinence (PPI) treatment with adjustable transobturator male system (ATOMS).

Materials And Methods: We carried out a longitudinal study on 77 males treated for PPI with ATOMS. Patients were submitted preoperatively to a urodynamic study.

View Article and Find Full Text PDF

Objective: To investigate the effect of perioperative complications involving artificial urinary sphincter (AUS) implantation on rates of explantation and continence as well as health-related quality of life (HRQOL).

Materials And Methods: Inclusion criteria encompassed non-neurogenic, moderate-to-severe stress urinary incontinence (SUI) post radical prostatectomy and primary implantation of an AUS performed by a high-volume surgeon (>100 previous implantations). Reporting complications followed the validated Clavien-Dindo scale and Martin criteria.

View Article and Find Full Text PDF

Aims: To comparatively analyse outcomes after ARGUS classic and ArgusT adjustable male sling implantation in a real-world setting.

Methods: Inclusion criteria encompassed: non-neurogenic, moderate-to-severe stress urinary incontinence (≥2 pads), implantation of an ARGUS classic or ArgusT male sling between 2010 and 2012 in a high-volume center (>150 previous implantations). Functional outcomes were assessed using daily pad usage, 24-hour pad testing, and International Consultation on Incontinence (ICIQ-SF) questionnaires.

View Article and Find Full Text PDF

Purpose: The aim was to study the correlation between cuff size and outcome after implantation of an AMS 800 artificial urinary sphincter.

Methods: A total of 473 male patients with an AMS 800 sphincter implanted between 2012 and 2014 were analyzed in a retrospective multicenter cohort study performed as part of the Central European Debates on Male Incontinence (DOMINO) Project.

Results: Single cuffs were implanted in 54.

View Article and Find Full Text PDF

Purpose: To compare the efficacy and perioperative complications of the AdVanceXP with the original AdVance male sling.

Methods: We retrospectively enrolled 109 patients with an AdVance and 185 patients with an AdVanceXP male sling. The baseline characteristics and complication rates were analyzed retrospectively.

View Article and Find Full Text PDF

Introduction: To evaluate the safety and efficacy of the TiLOOP® male sling (pfm medical, Cologne, Germany) used in the treatment for male stress urinary incontinence (SUI).

Material And Methods: We retrospectively evaluated a total of 34 patients with a TiLOOP® male sling. Perioperative complication rates were assessed and validated questionnaires were prospectively evaluated to assess quality of life and satisfaction rate.

View Article and Find Full Text PDF