Publications by authors named "F Stumpp"

Objective: To compare detection rates of glaucomatous visual field defects (VFDs) between the conventional 6 degrees x 6 degrees stimulus grid and locally condensed target arrangements in morphologically suspicious regions.

Methods: A total of 66 eyes of 66 patients with glaucoma or patients suspected of having glaucoma (34 females and 32 males; age range, 14-85 years) were enrolled in this study. Individual, local target condensation was realized by fundus-oriented perimetry (FOP) using a campimeter and compared with the results of conventional automated perimetry (CAP), obtained with the Humphrey Field Analyzer (30-2 grid).

View Article and Find Full Text PDF

Purpose: We compared detection rates of glaucomatous visual field defects (VFDs) between a conventional rectangular stimulus grid and locally condensed test point arrangements in morphologically suspicious regions.

Methods: Humphrey Field Analyzer model 630 (HFA I, program 30-2 with a rectangular 6 degrees x 6 degrees grid) was used as the conventional perimetric method. Individual local test-point condensation was realized by fundus-oriented perimetry (FOP) on the Tuebingen Computer Campimeter (TCC).

View Article and Find Full Text PDF