Publications by authors named "F Stichelbaut"

The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H(*)(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS).

View Article and Find Full Text PDF

Proton range monitoring may facilitate online adaptive proton therapy and improve treatment outcomes. Imaging of proton-induced prompt gamma (PG) rays using a knife-edge slit collimator is currently under investigation as a potential tool for real-time proton range monitoring. A major challenge in collimated PG imaging is the suppression of neutron-induced background counts.

View Article and Find Full Text PDF

In this work, we present experimental results of a prompt gamma camera for real-time proton beam range verification. The detection system features a pixelated Cerium doped lutetium based scintillation crystal, coupled to Silicon PhotoMultiplier arrays, read out by dedicated electronics. The prompt gamma camera uses a knife-edge slit collimator to produce a 1D projection of the beam path in the target on the scintillation detector.

View Article and Find Full Text PDF

This paper's goal is to assess secondary neutron doses received by paediatric patients treated for intracranial tumours using a 178 MeV proton beam. The MCNPX Monte Carlo model of the proton therapy facility, previously validated through experimental measurements for both proton and neutron dosimetry, was used. First, absorbed dose was calculated for organs located outside the clinical target volume using a series of hybrid computational phantoms for different ages and considering a realistic treatment plan.

View Article and Find Full Text PDF

Proton therapy offers several advantages compared with classical radiotherapy owing to a better dose conformity to the tumour volume. However, proton interactions with beam transport elements and the human tissues lead to the production of secondary neutrons, resulting in an extra whole-body dose with some carcinogenic potential. In this study, the secondary neutron doses generated with an active beam scanning system and with two compact proton therapy systems recently appeared on the market are compared.