Publications by authors named "F Poenisch"

Background: Current fiducial markers (FMs) in external-beam radiotherapy (EBRT) for prostate cancer (PCa) cannot be positively visualized on magnetic resonance imaging (MRI) and create dose perturbation and significant imaging artifacts on computed tomography (CT) and MRI. We report our initial experience with clinical imaging of a novel multimodality FM, NOVA.

Methods: We tested Gold Anchor [G-FM], BiomarC [carbon, C-FM], and NOVA FMs in phantoms imaged with kilovoltage (kV) X-rays, transrectal ultrasound (TRUS), CT, and MRI.

View Article and Find Full Text PDF

Our randomized clinical study comparing stereotactic body radiotherapy (SBRT) and stereotactic body proton therapy (SBPT) for early stage non-small cell lung cancer (NSCLC) was closed prematurely owing to poor enrollment, largely because of lack of volumetric imaging and difficulty in obtaining insurance coverage for the SBPT group. In this article, we describe technology improvements in our new proton therapy center, particularly in image guidance with cone beam CT (CBCT) and CT on rail (CTOR), as well as motion management with real-time gated proton therapy (RGPT) and optical surface imaging. In addition, we have a treatment planning system that provides better treatment plan optimization and more accurate dose calculation.

View Article and Find Full Text PDF

The recently observed FLASH effect related to high doses delivered with high rates has the potential to revolutionize radiation cancer therapy if promising results are confirmed and an underlying mechanism understood. Comprehensive measurements are essential to elucidate the phenomenon. We report the first-ever demonstration of measurements of successive in-spill and post-spill emissions of gammas arising from irradiations by a FLASH proton beam.

View Article and Find Full Text PDF

We demonstrate the first ever recorded positron-emission tomography (PET) imaging and dosimetry of a FLASH proton beam at the Proton Center of the MD Anderson Cancer Center. Two scintillating LYSO crystal arrays, read out by silicon photomultipliers, were configured with a partial field of view of a cylindrical poly-methyl methacrylate (PMMA) phantom irradiated by a FLASH proton beam. The proton beam had a kinetic energy of 75.

View Article and Find Full Text PDF

Purpose: We developed and tested a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources similar to those for regular intensity-modulated proton therapy (IMPT) plans and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries.

Methods: Our IMPAT planning method consists of a geometry-based energy selection step with major scanning spot contributions as inputs computed using ray-tracing and single-Gaussian approximation of lateral spot profiles. Based on the geometric relation of scanning spots and dose voxels, our energy selection module selects a minimum set of energy layers at each gantry angle such that each target voxel is covered by sufficient scanning spots as specified by the planner, with dose contributions above the specified threshold.

View Article and Find Full Text PDF