The massive usage of per- and polyfluoroalkyl substances (PFAS), as well as their high chemical stability, have led to their ubiquitous presence in environmental matrices and direct human exposure through contaminated food, particularly fish. In the analysis of this large group of substances, the use of ion mobility coupled to mass spectrometry is of particular relevance because it uses an additional descriptor, the collision cross-section (CCS), which results in increased selectivity. In the present work, the CCS of 24 priority PFAS were experimentally obtained, and the reproducibility of these measurements was evaluated over seven weeks.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
November 2022
An Ultra-High Performance Supercritical Fluid Chromatography coupled with tandem Mass Spectrometry analytical method (UHPSFC-MS/MS) was developed for the determination of 34 perfluoroalkylated substances (PFASs) in food-related matrices. Two parameters (i.e.
View Article and Find Full Text PDFIn order to overcome the challenge associated with the screening of Anabolic-Androgenic Steroids abuses in animal competitions, a non-targeted liquid chromatography coupled to high resolution mass spectrometry based metabolomics approach was implemented on equine urine samples to highlight potential biomarkers associated with the administration of such compounds, using testosterone esters as model steroids. A statistical model relying on four potential biomarkers intensity could be defined to predict the status of the samples. With a routine application perspective, the monitoring of the highlighted potential biomarkers was first transferred into high-throughput liquid chromatography-selected reaction monitoring (LC-SRM).
View Article and Find Full Text PDFThe aim of this study was to assess the interlaboratory reproducibility of ultra-high performance supercritical fluid chromatography coupled with tandem mass spectrometry method for routine antidoping analyses. To do so, a set of 21 doping agents, spiked in urine and analyzed after dilute and shoot treatment, was used to assess the variability of their retention times between four different laboratories, all equipped with the same chromatographic system and with the same ultra-high performance supercritical fluid chromatography stationary phase chemistry. The average relative standard deviations (RSD%) demonstrated a good reproducibility of the retention times for 19 out of 21 analytes, with RSD% values below 3.
View Article and Find Full Text PDF