Background: "Fast Track surgery" is a therapeutic program of large application, despite some doubts about its applicability and real validity. Literature review shows that this approach to colo-rectal surgery, particularly video-assisted, can allow a rapid recovery, better performance and a faster postoperative functional autonomy of the work, which can be discharged without cause additional welfare costs; in addition it can be reproducible in different health reality.
Purpose: To analyze the possibility to apply the Fast Truck protocol in patients undergoing colorectal surgery in a rural hospital and non specialistic Unit of Surgery.
We report the first measurement of the parity-violating asymmetry A(PV) in the elastic scattering of polarized electrons from 208Pb. A(PV) is sensitive to the radius of the neutron distribution (R(n)). The result A(PV)=0.
View Article and Find Full Text PDFThe ratio of the electromagnetic proton elastic form factors, G(p)(E)/G(p)(M), has been measured at Jefferson Lab up to Q(2) approximately 9(GeV/c)(2), by using the CEBAF 6GeV electron beam, and revealing an unexpected and challenging physical behaviour. The 2014 scheduled 12GeV upgrade will allow the measurement of G(p)(E)/G(p)(M) up to Q(2) approximately 15(GeV/c)(2), by taking advantage of the new large-acceptance forward spectrometer Super BigBite (SBS) in Hall A. Measurements of neutron form factors in the region around 10(GeV/c)(2), where quark confinement plays an important role, are expected to show the behaviour already observed in the proton case.
View Article and Find Full Text PDFThe "standard" Hall A apparatus at Jefferson Lab (TOF and aerogel threshold Cherenkov detectors) does not provide complete identification for proton, kaon and pion. To this aim, a proximity focusing C(6)F(14)/CsI RICH (Ring Image CHerenkov) detector has been designed, built, tested and operated to separate kaons from pions with a pion contamination of a few percent up to 2.4GeV/c.
View Article and Find Full Text PDFThe possibility of anisotropies in the speed of light relative to the limiting speed of electrons is considered. The absence of sidereal variations in the energy of Compton-edge photons at the European Synchrotron Radiation Facility's GRAAL facility constrains such anisotropies representing the first nonthreshold collision-kinematics study of Lorentz violation. When interpreted within the minimal standard-model extension, this result yields the two-sided limit of 1.
View Article and Find Full Text PDF