Postoperative tests of implantable cardioverter defibrillators (ICDs) are routinely performed to ensure appropriate defibrillation by the device. However, efficacy and complications of this procedure are unknown. To scrutinize the currently accepted indications to test the defibrillation function of the ICD we retrospectively analyzed 844 ICD-tests in 439 ICD-systems and 409 patients.
View Article and Find Full Text PDFPacing Clin Electrophysiol
August 1996
Adequate sensing is a basic requirement for appropriate therapy with ICDs. Integrated sense pace defibrillation leads, which facilitate ICD implantation, show a close proximity of sensing and defibrillation electrodes that might affect the sensing signal amplitude by the high currents of internal defibrillation. In 99 patients, we retrospectively examined two integrated sense pace defibrillation leads, either both with a distance of 6 mm between the tip of the lead (sensing cathode) and the right ventricular defibrillation electrode (sensing anode) or one with a distance of 12 mm.
View Article and Find Full Text PDFPacing Clin Electrophysiol
February 1996
The volume of current implantable cardioverter defibrillators (ICD) is not convenient for pectoral implantation. One way to reduce the size of the pulse generator is to find a more effective defibrillation pulse waveform generated from smaller volume capacitors. In a prospective randomized crossover study we compared the step-down defibrillation threshold (DFT) of a standard biphasic waveform (STD), delivered by two 250-microF capacitors connected in series with an 80% tilt, to an experimental biphasic waveform delivered by a single 450-microF capacitor with a 60% tilt.
View Article and Find Full Text PDFBackground: The availability of implantable cardioverter-defibrillators (ICD) that are capable of antitachycardia pacing may lead to an increased use of ICDs in patients with haemodynamically tolerated ventricular tachycardia without a history of cardiac arrest. The frequency of potentially life-threatening fast ventricular tachycardias (cycle length < 250 ms) was investigated in patients who had a third generation ICD with endocardial leads implanted because they had haemodynamically tolerated ventricular tachycardia without a history of cardiac arrest.
Methods: Between January 1990 and October 1993, 50 patients (age (mean (SD)) 60 (11); ejection fraction 39 (16)%; 82% with coronary artery disease and 8% with dilated cardiomyopathy) with haemodynamically tolerated ventricular tachycardia (cycle length (mean (SD)) 348 (60) ms; range 250-500 ms) and without a history of cardiac arrest were treated with third generation ICDs that were capable of antitachycardia pacing.
J Cardiovasc Electrophysiol
November 1994
Introduction: The defibrillation threshold (DFT) of a transvenous-subcutaneous electrode configuration is sometimes unacceptably high. To obtain a DFT with a sufficient safety margin, the defibrillation field can be modified by repositioning the electrodes or more easily by a change of electrode polarity. In a prospective randomized cross-over study, the effect of transvenous electrode polarity on DFT was evaluated.
View Article and Find Full Text PDF