Publications by authors named "F Kehren"

With the addition of variable bed speed capabilities, continuous bed motion (CBM) becomes an acquisition generalization for axial sensitivity modeling and therefore a flexible tool in axial local image quality adjustment. In this paper, we describe the principles behind CBM mode planning and its influence on image reconstruction. The data correction method underwent the most changes compared to the commonly used step and shoot (S&S) mode.

View Article and Find Full Text PDF

Positron emission tomographs (PETs) are currently almost exclusively designed as hybrid systems. The current standard is the PET/CT combination, while prototype PET/MRI systems are being studied by several research groups. One problem in these systems is that the transaxial field-of-view of the second system is smaller than that of the PET camera and does not provide complete attenuation data.

View Article and Find Full Text PDF

The quality of images reconstructed by statistical iterative methods depends on an accurate model of the relationship between image space and projection space through the system matrix The elements of the system matrix for the clinical Hi-Rez scanner were derived by processing the data measured for a point source at different positions in a portion of the field of view. These measured data included axial compression and azimuthal interleaving of adjacent projections. Measured data were corrected for crystal and geometrical efficiency.

View Article and Find Full Text PDF

Time-of-flight (TOF) positron emission tomography (PET) was studied and preliminarily developed in the 1980s, but the lack of a scintillator able to deliver at the same time proper time resolution and stopping power has prevented this technique from becoming widespread and commercially available. With the introduction of LSO in PET, TOF is now a feasible option. TOF reconstruction has been implemented in the CPS Hi-Rez PET scanner, both with 2D filtered-back-projection (FBP2D) and 3D ordered subset expectation maximization (OSEM3D).

View Article and Find Full Text PDF

Simultaneous emission and transmission measurement is appealing in PET due to the matching of geometrical conditions between emission and transmission and reduced acquisition time for the study. A potential problem remains: when transmission statistics are low, attenuation correction could be very noisy. Although noise in the attenuation map can be controlled through regularization during statistical reconstruction, the selection of regularization parameters is usually empirical.

View Article and Find Full Text PDF