Publications by authors named "F A S Peternella"

The presence of opportunistic bacteria such as coagulase-negative Staphylococcus (CoNS) in drinking water poses public health concerns because of its potential to cause human infection and due to its antimicrobial resistance (AMR) diversity. This study evaluated the occurrence, virulence markers and AMR of CoNS in 468 drinking water samples from 15 public fountains located in four urban parks of São Paulo city (Brazil). Out of 104 samples positive for the presence of Staphylococcus genus, we detected CoNS in 75 of them (16%), which did not meet the Brazilian sanitary standards for residual chlorine.

View Article and Find Full Text PDF

The absence of a standardized method for detecting oocysts in water samples makes it difficult to characterize them, including in water for reuse. This study aimed to detect Toxoplasma gondii oocysts using two extraction methods. Using method 1693/2014 USEPA, 30 L of water for reuse from two wastewater treatment plants (WWTPs) in the city of São Paulo, Brazil, was concentrated, totaling 20 samples.

View Article and Find Full Text PDF

The presence of Staphylococcus aureus in drinking water is a concern because of its potential to cause human infection and also because of its multiple antimicrobial resistance. This study evaluated the water quality of drinking water fountains and mist makers in four municipal parks of São Paulo for 13 months. Although all samples met bacteriological water quality criteria according to Brazilian regulations, the absence of residual chlorine (<0.

View Article and Find Full Text PDF

In this paper, the design and the characterization of a novel interrogator based on integrated Fourier transform (FT) spectroscopy is presented. To the best of our knowledge, this is the first integrated FT spectrometer used for the interrogation of photonic sensors. It consists of a planar spatial heterodyne spectrometer, which is implemented using an array of Mach-Zehnder interferometers (MZIs) with different optical path differences.

View Article and Find Full Text PDF

We experimentally demonstrate an interrogation procedure of a ring-resonator ultrasound sensor using a fiber Mach-Zehnder interferometer (MZI). The sensor comprises a silicon ring resonator (RR) located on a silicon-oxide membrane, designed to have its lowest vibrational mode in the MHz range, which is the range of intravascular ultrasound (IVUS) imaging. Ultrasound incident on the membrane excites its vibrational mode and as a result induces a modulation of the resonance wavelength of the RR, which is a measure of the amplitude of the ultrasound waves.

View Article and Find Full Text PDF