The artificial pancreas system or an automated insulin dosing system has been the 'holy grail' for patients with type 1 diabetes and their caregivers who have over the years wanted to 'close the loop' between monitoring of glucose and delivery of insulin. The launch of the Medtronic MiniMed 670G system in 2017 and the subsequent release of the Tandem t:slim with Control-IQ system, the DANA RS pump compatible-CamAPS FX app and the more recent announcement of the Medtronic MiniMed 780G system have come as answers to their prayers. However, in the time taken to develop and launch these commercial systems, creative and ebullient parents of young patients with type 1 diabetes, along with other patients, technologists and healthcare professionals have developed mathematical models as software solutions to determine insulin delivery that in conjunction with compatible hardware have helped 'close the loop'.
View Article and Find Full Text PDFBackground: Minimum Toe Clearance (MTC) is defined as the minimum vertical distance between the lowest point under the front part of the foot and the ground, during mid-swing. Low values of MTC and walking on inclines are both related to higher probability of tripping and falling in lower limb amputees. New prosthetic designs aim at improving MTC, especially on ramps, however the real effect on MTC still needs investigation.
View Article and Find Full Text PDFSlope ambulation is a challenge for trans-femoral amputees due to a relative lack of knee function. The assessment of prosthetic ankles on slopes is required for supporting the design, optimisation, and selection of prostheses. This study assessed two hydraulic ankle-foot devices (one of the hydraulic ankles is controlled by a micro-processor that allows real-time adjustment in ankle resistance and range of motion) used by trans-femoral amputees in ascending and descending a 5-degree slope walking, against a rigid ankle-foot device.
View Article and Find Full Text PDFHypoglycaemia is a well-documented 'stroke mimic'. The literature documents numerous case reports of patients presenting with focal neurological deficits subsequently attributed to hypoglycaemia. The significant majority of these cases are found in patients with pre-existing diabetes.
View Article and Find Full Text PDFBackground: Substantial improvements have been perceived in surgical results following major lower limb amputation, but there remains observed variation in amputation quality for patients referred for prosthetic rehabilitation from different hospitals.
Objectives: To assess various elements that influence residual limb quality and evaluate their impact on progress through initial prosthetic rehabilitation and mobility outcome after rehabilitation.
Study Design: Clinical survey.
Background: Stair-related falls of older people cause a substantial financial and social burden. Deterioration of the visual system amongst other factors put older people at a high risk of falling. Improved lighting is often recommended.
View Article and Find Full Text PDFWe present the case of a patient with Cushing's syndrome secondary to ectopic ACTH secretion. A MR of the head showed a left-sided nasal mass extending down from the cribriform plate. The patient underwent endoscopic resection with nearly complete removal of the mass.
View Article and Find Full Text PDFImproved walking comfort has been linked with better bio-mimicking of the prosthetic ankle. This study investigated if a hydraulic ankle/foot can provide enough motion in both the sagittal and frontal planes during level and camber walking and if the hydraulic ankle/foot better mimics the biological ankle moment pattern compared with a fixed ankle/foot device. Five active male unilateral trans-femoral amputees performed level ground walking at normal and fast speeds and 2.
View Article and Find Full Text PDFPhilos Trans A Math Phys Eng Sci
September 2015
Model validation using data from modal tests is now widely practiced in many industries for advanced structural dynamic design analysis, especially where structural integrity is a primary requirement. These industries tend to demand highly efficient designs for their critical structures which, as a result, are increasingly operating in regimes where traditional linearity assumptions are no longer adequate. In particular, many modern structures are found to contain localized areas, often around joints or boundaries, where the actual mechanical behaviour is far from linear.
View Article and Find Full Text PDFUse of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation.
View Article and Find Full Text PDFGyroscopes have been proposed as sensors for ambulatory gait analysis and functional electrical stimulation systems. These applications often require detection of the initial contact (IC) of the foot with the floor and/or final contact or foot off (FO) from the floor during outdoor walking. Previous investigations have reported the use of a single gyroscope placed on the shank for detection of IC and FO on level ground and incline walking.
View Article and Find Full Text PDFA recent development in prosthetics is the osseointegrated fixation (OF), with improvements in comfort, fatigue, hip movement, and ease of prosthetic attachment reported. However, little information is available regarding muscle function. This study reports on selected gait parameters of the residual limb during the stance phase of level overground walking, focusing on muscle activity.
View Article and Find Full Text PDFThe aim of this review paper is to consider the application of neuromuscular electrical stimulation (NMES) to improve gait or upper limb function in children with cerebral palsy (CP). Although most NMES research has been directed at adults with neurological conditions, there is a growing body of evidence supporting its use in children with CP. In line with a recent meta-analysis, the use of electrical stimulation to minimise impairment and activity limitations during gait is cautiously advocated.
View Article and Find Full Text PDFNeuropsychologia
September 2011
The present study examined how asymmetrical motor symptomatology helps predict the pattern of perceptual judgements of body-scaled aperture width in lateralised Parkinson's disease (PD). Eleven patients with PD predominantly affecting the left side of their body (LPD), 16 patients with PD predominantly affecting their right side (RPD), and 16 healthy controls made forced-choice judgements about whether or not they would fit without turning their shoulders through a life-sized schematic doorway shown on a large screen. Whereas control and LPD groups made accurate estimations of body-scaled aperture width, RPD patients significantly underestimated aperture width relative to their body, perceiving doorways on average that were 12% narrower than their bodies as wide enough to allow them to pass through without rotation.
View Article and Find Full Text PDFBackground: Femoral osseointegrated implants represent a new development in amputee rehabilitation, eliminating socket pressure discomfort, improving hip range of movement and facilitating prosthetic limb attachment. A clinical aspect that has not previously been reported on is the function of muscles in the residuum with implications concerning energy expenditure, hip-hiking and viability of the electrogram as a myoprocessor. Typically, amputees fitted with osseointegrated fixation have shorter residuums and weaker attachment of cleaved muscles.
View Article and Find Full Text PDFThe Ponseti method for clubfoot treatment offers satisfactory initial correction, but success correlates with abduction brace compliance, which is variable. Electrical stimulation as a dynamic intervention to prevent relapses was investigated. Data were compared to a control group.
View Article and Find Full Text PDFGyroscopes have been proposed as sensors for ambulatory gait analysis and functional electrical stimulation systems. Accurate determination of the Initial Contact of the foot with the floor (IC) and the final contact or Foot Off (FO) on different terrains is important. This paper describes the evaluation of a gyroscope placed on the shank for determination of IC and FO in subjects walking outdoors on level ground, and up and down an incline.
View Article and Find Full Text PDFJ Pediatr Orthop B
September 2009
Static measures data for infants are used in clinical practice and studies without published reliabilities. Intraobserver reliabilities for static measures were assessed in normally developing feet and clubfeet. Coefficient of repeatability was used for reliability.
View Article and Find Full Text PDFBackground: Pathways to guide clinical care are well accepted and used in many emergency departments. We wanted to introduce a number ("bundle") over a short space of time and involve the whole patient stay in the pathway. It was hypothesised that a more efficient process would result with an overall reduction in length of stay (LoS).
View Article and Find Full Text PDFKinematic gait analysis is limited by simplified marker sets and related models. The majority of sets in clinical use were developed with low resolution imaging systems so required various assumptions about body behaviour. Further major limitations include soft tissue artefact and ambiguity in landmark identification.
View Article and Find Full Text PDFA portable system capable of accurate detection of initial contact (IC) and foot off (FO) without adding encumbrance to the subject would be extremely useful in many gait analysis applications. Force platforms represent the gold standard method for determining these events and other methods including foot switches and kinematic data have also been proposed. These approaches, however, present limitations in terms of the number of steps that can be analysed per trial, the portability for outdoor measurements or the information needed beforehand.
View Article and Find Full Text PDF