Aim: To compare the biomechanical properties of a newly proposed technique, utilizing intramedullary nailing and compression bolts, for the osteosynthesis of intra-articular proximal tibial fractures with meta-diaphyseal comminution, with modern and conventional plating techniques.
Methods: Fifteen left tibia 4th generation composite Sawbones models (in 3 groups of 5 for each technique) with identically reproduced type VI Schatzker tibial plateau fractures, including meta-diaphyseal dissociation, were used. Three different techniques of osteosynthesis were tested: (a) a new technique that combines intramedullary nailing and compression bolts, (b) internal fixation with a single lateral locking plate and (c) internal fixation with dual buttress plating technique.