Background/aims: The dialysis delivered dose is limited by the rate at which urea can be transferred from the different body compartments. The time needed to clear the peripheral compartments of the body has been called the patient clearance time (tp). The aim of the study was to compare delivered dialysis dose using the tp index between patients dialyzed through a permanent central venous catheter (CVC) and patients with an arteriovenous fistula (AVF).
View Article and Find Full Text PDFBackground/aim: Hyperphosphatemia is a well-recognized complication of chronic kidney disease, and phosphorus kinetics during hemodialysis (HD) remains a vague area of investigation. We studied the inorganic phosphorus homeostasis during the first hour of an HD session.
Materials/methods: Twelve patients were studied twice, in two consecutive HD sessions.