Chinese hamster ovary (CHO) cells are widely used to produce complex biopharmaceuticals. Improving their productivity is necessary to fulfill the growing demand for such products. One way to enhance productivity is by cultivating cells at high densities, but inhibitory by-products, such as metabolite derivatives from amino acid degradation, can hinder achieving high cell densities.
View Article and Find Full Text PDFChinese Hamster Ovary (CHO) cells have rapidly become a cornerstone in biopharmaceutical production. Recently, a reinvigoration of perfusion culture mode in CHO cell cultivation has been observed. However, most cell lines currently in use have been engineered and adapted for fed-batch culture methods, and may not perform optimally under perfusion conditions.
View Article and Find Full Text PDFThe manufacturing scale implementation of membrane chromatography to purify monoclonal antibodies has gradually increased with the shift in industry focus toward flexible manufacturing and disposable technologies. Membrane chromatography are used to remove process-related impurities such as host cell proteins (HCPs) and DNA, leachates, and endotoxins, with improved productivity and process flexibility. However, application of membrane chromatography to separate product-related variants such as charge variants has not gained major traction due to low-binding capacity.
View Article and Find Full Text PDFThe reliable and cost-efficient manufacturing of monoclonal antibodies (mAbs) is essential to fulfil their ever-growing demand. Cell death in bioreactors reduces productivity and product quality, and is largely attributed to apoptosis. In perfusion bioreactors, this leads to the necessity of a bleed stream, which negatively affects the overall process economy.
View Article and Find Full Text PDFChinese hamster ovary (CHO) cells are the primary platform for the production of biopharmaceuticals. To increase yields, many CHO cell lines have been genetically engineered to resist cell death. However, the kinetics that governs cell fate in bioreactors are confounded by many variables associated with batch processes.
View Article and Find Full Text PDFMuch of the biopharmaceutical industry's success over the past 30 years has relied on products derived from Chinese Hamster Ovary (CHO) cell lines. During this time, improvements in mammalian cell cultures have come from cell line development and process optimization suited for large-scale fed-batch processes. Originally developed for high cell densities and sensitive products, perfusion processes have a long history.
View Article and Find Full Text PDFThe need to intensify downstream processing of monoclonal antibodies to complement the advances in upstream productivity has led to increased attention toward implementing membrane technologies. With the industry moving toward continuous operations and single use processes, membrane technologies show promise in fulfilling the industry needs due to their operational flexibility and ease of implementation. Recently, the applicability of membrane-based unit operations in integrating the downstream process has been explored.
View Article and Find Full Text PDFRapid advances in intensifying upstream processes for biologics production have left downstream processing as a bottleneck in the manufacturing scheme. Biomanufacturers are pursuing continuous downstream process development to increase efficiency and flexibility, reduce footprint and cost of goods, and improve product consistency and quality. Even after successful laboratory trials, the implementation of a continuous process at manufacturing scale is not easy to achieve.
View Article and Find Full Text PDFThe Biflow, a new isoelectric trapping instrument was designed to obtain a narrow DeltapI fraction from a complex feed in one step. The Biflow contains two identical separation units, each unit houses: an anode and cathode compartment, an anodic and cathodic membrane, an anodic and cathodic separation compartment, and a separation membrane. The separation units are connected to independent power supplies.
View Article and Find Full Text PDFA recirculating, preparative-scale isoelectric trapping device, developed for the binary isoelectric trapping separation of proteins has been used to desalt, isolate and enrich the pI<4 protein fraction from a 150 mL sample of bovine serum. Subsequent re-separation of the 2
Electrophoresis
February 2007
The pH transients that occur during isoelectric trapping separations as a result of the removal of nonampholytic ionic components have been re-examined. Salts containing strong electrolyte anions and cations, both with equal and dissimilar mobilities, have been studied using anodic and cathodic buffering membranes whose pH values were both equidistant and nonequidistant from pH 7. The direction and magnitude of the pH transient (acidic or basic) was found to depend on both the mobilities of the anion and cation (mu(anion)/mu(cation)) and the pH difference between pH 7 and the pH of the buffering membranes (|pH(memb) (anodic) - 7|/|7 - pH(memb) (cathodic)|).
View Article and Find Full Text PDFSuccess in isoelectric trapping separations critically depends on the knowledge of the accurate operational pH value of the buffering membranes used. Currently, due to a lack of easy, rapid, accurate methods that can be used for the post-synthesis determination of the operational pH value of a buffering membrane, only nominal pH values calculated from the amounts of the reagents used in the synthesis of the membranes and their acid-base dissociation constants are available. To rectify this problem, UV-absorbing and fluorescent carrier ampholyte mixtures were prepared by alkylating pentaethylenehexamine with a chromophore and a fluorophore, followed by Michael addition of acrylic acid and itaconic acid to the resulting oligoamine.
View Article and Find Full Text PDFHydrolytically stable, low-pI isoelectric membranes have been synthesized from low-pI ampholytic components, poly(vinyl alcohol), and a bifunctional cross-linker, glycerol-1,3-diglycidyl ether. The low-pI ampholytic components used contain one amino group and at least two weakly acidic functional groups. The acidic functional groups are selected such that the pI value of the ampholytic component is determined by the pK(a) values of the acidic functional groups.
View Article and Find Full Text PDFAlkali-stable, high-pI isoelectric membranes have been synthesized from quaternary ammonium derivatives of cyclodextrins and poly(vinyl alcohol), and bifunctional cross-linkers, such as glycerol-1,3-diglycidyl ether. The new, high-pI isoelectric membranes were successfully applied as cathodic membranes in isoelectric trapping separations in place of the hydrolytically more labile, polyacrylamide-based cathodic isoelectric membranes, and permitted the use of catholytes as alkaline as 1 M NaOH. The new high-pI isoelectric membranes have shown excellent mechanical stability, low electric resistance and long life times, even when subjected to electrophoresis with current densities as high as 80 mA/cm2.
View Article and Find Full Text PDFJ Chromatogr A
May 2004
The typically low aqueous solubilities of small, hydrophobic organic ampholytic molecules limit the production rates that can be achieved in their isoelectric trapping (IET) separations and call for the use of hydro-organic mixtures as solvents. The compatibility of methanol-water mixtures and poly(ethylene terephthalate) substrate-supported isoelectric polyacrylamide hydrogels, developed for binary IET separations in a Gradiflow BF200IET unit, was investigated. The isoelectric polyacrylamide-based hydrogels retained their functional and mechanical integrities when the methanol concentration in the hydro-organic solvent mixture was kept at or below 25% (v/v).
View Article and Find Full Text PDFElectrophoresis
January 2004
In order to improve the production rates and lower the specific electrophoretic energy consumption values in preparative-scale, recirculating, binary isoelectric trapping separations, we propose to add an auxiliary isoelectric agent to the solution in the anodic separation compartment and another to the solution in the cathodic separation compartment to implement pH-biased isoelectric trapping. The auxiliary isoelectric agents are selected such that they are trapped in the respective anodic and cathodic separation compartments and also, have isoelectric point (pI) values that are different from the pI values of the analytes of interest. By proper selection of the auxiliary isoelectric agents and their concentrations, the analytes of interest can be kept in nonisoelectric, charged state during the entire course of the preparative-scale, recirculating, binary isoelectric trapping separation.
View Article and Find Full Text PDFThe new Gradiflow BF200 IET unit, developed for isoelectric trapping protein separations has been modified and used to carry out preparative-scale enantiomer separations. Hydroxypropyl beta-cyclodextrin was used as the chiral resolving agent to induce an isoelectric point difference between the enantiomers. Three isoelectric membranes with isoelectric points below, in between and above the isoelectric points of the complexed enantiomers were used to trap the separated enantiomers in the anodic and cathodic separation compartments of the Gradiflow BF200 IET apparatus, respectively.
View Article and Find Full Text PDFThe Gradiflow BF200 preparative electrophoretic unit (Gradipore), which has been developed for size-based and charge-sign-based protein separations and in which the hydraulic flow path of the recirculating sample stream in the separation cartridge is orthogonal to the electric field, has been modified to carry out binary protein separations using the principles of isoelectric trapping. The disposable separation cartridge contained three isoelectric membranes which, along with the cartridge holder, formed the anode and cathode compartments and the anodic and cathodic separation compartments. The utility of the modified instrument was demonstrated by effecting a binary separation of chicken egg white across an isoelectric point 5.
View Article and Find Full Text PDF