Objectives: Hexavalent chromium (Cr(VI)) is classified as a human carcinogen. Occupational Cr(VI) exposure can occur during different work processes, but the current exposure to Cr(VI) at Swedish workplaces is unknown.
Methods: This cross-sectional study (SafeChrom) recruited non-smoking men and women from 14 companies with potential Cr(VI) exposure (n = 113) and controls from 6 companies without Cr(VI) exposure (n = 72).
Biosens Bioelectron
January 2016
Wastewater samples from a Swedish chemi-thermo-mechanical pulp (CTMP) mill collected at different purification stages in a wastewater treatment plant (WWTP) were analyzed with an amperometric enzyme-based biosensor array in a flow-injection system. In order to resolve the complex composition of the wastewater, the array consists of several sensing elements which yield a multidimensional response. We used principal component analysis (PCA) to decompose the array's responses, and found that wastewater with different degrees of pollution can be differentiated.
View Article and Find Full Text PDFIn this paper, it is demonstrated that a single-receptor biosensor can be used to quantitatively determine each analyte in binary mixtures using multivariate data analysis tools based on the dynamic responses received from flow injection peaks. Mixtures with different concentrations of two phenolic compounds, catechol and 4-chlorophenol, were measured with a graphite electrode modified with tyrosinase enzyme at an applied potential of -50mV versus Ag/AgCl. A correction algorithm based on measurements of references in-between samples was applied to compensate for biosensor ageing as well as differences caused by deviations between biosensor preparations.
View Article and Find Full Text PDFFour wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chemi-thermo-mechanical pulp mill and pure water were investigated using an amperometric bio-electronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase.
View Article and Find Full Text PDFDirect electron transfer (DET) was shown between the heme containing enzyme theophylline oxidase (ThO) and the surface of both graphite and gold electrodes. As proof on graphite a steady state current for theophylline was recorded using the electrode modified with adsorbed ThO. The electrode showed a Michaelis-Menten-like response to theophylline with a detection limit of 0.
View Article and Find Full Text PDF