Publications by authors named "Eugene Wright"

Article Synopsis
  • An error grid is a tool that helps compare glucose levels measured by devices to see if they are correct and to identify any risks.
  • Experts created a new error grid called the DTS Error Grid that works for both blood glucose monitors (BGMs) and continuous glucose monitors (CGMs), organizing accuracy into five risk zones.
  • The results showed that the DTS Error Grid provides a clearer picture of how accurate these devices are and includes a separate matrix to evaluate how well CGMs track glucose trends over time.
View Article and Find Full Text PDF

This podcast discusses innovations, advancements, and discoveries in continuous glucose monitoring that were presented at the American Diabetes Association 84 Scientific Sessions held in Orlando, Florida, June 2024. Specifically, the author will discuss sessions focused on (1) Equity and access to new technologies; (2) The role of the interdisciplinary team in technology onboarding in primary care; (3) New technologies for glucose monitoring and sensing; (4) New technologies for continuous glucose monitoring (CGM); and (5) CGM implementation in primary care.

View Article and Find Full Text PDF

People living with type 2 diabetes (T2D) and chronic kidney disease (CKD) are at risk of CKD progression and kidney failure. This is a summary of the FIDELITY pooled analysis where two clinical trials (FIDELIO-DKD and FIGARO-DKD) were performed to investigate the safety and efficacy of finerenone in people with T2D and CKD. The data from these two studies were combined and analyzed and it was found that those who took finerenone on top of standard-of-care medicine had a 14% reduced risk of having a cardiovascular event and 23% reduced risk of having a kidney event versus those who took placebo.

View Article and Find Full Text PDF

Introduction: Both glucagon-like peptide-1 receptor agonists (GLP-1 RA) and continuous glucose monitoring (CGM) improve glycemia in patients with type 2 diabetes (T2D). However, it is unknown whether adding CGM to GLP-1 RA therapy further improves A1c. We evaluated changes in A1c levels 6 months after initiation of FreeStyle Libre (FSL) in adults with sub-optimally controlled T2D already on GLP-1 RA therapy.

View Article and Find Full Text PDF
Article Synopsis
  • The spectrum of cardiorenal and metabolic diseases includes various disorders like obesity, type 2 diabetes, chronic kidney disease, and heart failure, often co-existing in the same patient due to shared physiological pathways.
  • Recent trials have shown that treatments can benefit multiple conditions simultaneously, highlighting a need for updated clinical guidance.
  • An international task force of specialists has created the DCRM 2.0 Practice Recommendations, which consist of 22 graphics to help clinicians manage these complex conditions effectively, aiming to enhance patient health and outcomes.
View Article and Find Full Text PDF

: Connected insulin pens capture data on insulin dosing/timing and can integrate with continuous glucose monitoring (CGM) devices with essential insulin and glucose metrics combined into a single platform. Standardization of connected insulin pen reports is desirable to enhance clinical utility with a single report. : An international expert panel was convened to develop a standardized connected insulin pen report incorporating insulin and glucose metrics into a single report containing clinically useful information.

View Article and Find Full Text PDF

Clinical practice guidelines for the management of chronic kidney disease (CKD) associated with type 2 diabetes (T2D) are designed to assist healthcare professionals with clinical decision making by providing recommendations on the screening, detection, management, and treatment of these conditions. However, primary care practitioners (PCPs) may have clinical inertia when it comes to routinely enacting CKD and T2D guideline recommendations in their clinical practices. Guideline developers have published a range of resources with the aim of facilitating easier access to guideline recommendations to support efficient and consistent implementation into clinical practice of PCPs.

View Article and Find Full Text PDF

Glucagon-like peptide-1 receptor agonists (GLP-1 RA) therapy provides glycemic benefits to individuals with type 2 diabetes (T2D). However, the effects of GLP-1 RA therapy in combination with FreeStyle Libre systems (FSL) are unknown. This study aimed to compare changes in hemoglobin A1c (HbA1c) between people acquiring GLP-1 with FSL (GLP-1+FSL) versus GLP-1 without FSL (GLP-1).

View Article and Find Full Text PDF

Diabetes technologies such as continuous glucose monitoring (CGM) continue to evolve at an increasingly rapid pace. Seventeen new CGM devices have been introduced to the market during the past decade. The introduction of each new system is supported by well-designed randomized controlled trials and real-world retrospective and prospective studies.

View Article and Find Full Text PDF

Studies that investigate use of diabetes technologies such as blood glucose monitoring (BGM) and continuous glucose monitoring (CGM) often report contradictory findings regarding efficacy and clinical utility. Whereas some studies of a given technology have shown no benefit, others have reported significant benefits. These incongruities derive from how the technology is viewed.

View Article and Find Full Text PDF

Diabetes is the leading cause of chronic kidney disease (CKD), a condition associated with significant morbidity and mortality. As these patients have a high risk of developing cardiovascular disease and end-stage kidney disease, there is a need for early detection and early initiation of appropriate therapeutic interventions that slow disease progression and prevent adverse outcomes. Due to the complex nature of diabetes and CKD management, a holistic, patient-centered, collaborative care approach delivered by a coordinated multidisciplinary team (ideally including a clinical pharmacist as part of a comprehensive medication management program) is needed.

View Article and Find Full Text PDF

Diabetes Technology Society assembled a panel of clinician experts in diabetology, cardiology, clinical chemistry, nephrology, and primary care to review the current evidence on biomarker screening of people with diabetes (PWD) for heart failure (HF), who are, by definition, at risk for HF (Stage A HF). This consensus report reviews features of HF in PWD from the perspectives of 1) epidemiology, 2) classification of stages, 3) pathophysiology, 4) biomarkers for diagnosing, 5) biomarker assays, 6) diagnostic accuracy of biomarkers, 7) benefits of biomarker screening, 8) consensus recommendations for biomarker screening, 9) stratification of Stage B HF, 10) echocardiographic screening, 11) management of Stage A and Stage B HF, and 12) future directions. The Diabetes Technology Society panel recommends 1) biomarker screening with one of two circulating natriuretic peptides (B-type natriuretic peptide or N-terminal prohormone of B-type natriuretic peptide), 2) beginning screening five years following diagnosis of type 1 diabetes (T1D) and at the diagnosis of type 2 diabetes (T2D), 3) beginning routine screening no earlier than at age 30 years for T1D (irrespective of age of diagnosis) and at any age for T2D, 4) screening annually, and 5) testing any time of day.

View Article and Find Full Text PDF

Increasing rates of obesity and diabetes have driven corresponding increases in related cardiorenal and metabolic diseases. In many patients, these conditions occur together, further increasing morbidity and mortality risks to the individual. Yet all too often, the risk factors for these disorders are not addressed promptly in clinical practice, leading to irreversible pathologic progression.

View Article and Find Full Text PDF

Comorbid type 2 diabetes mellitus (T2D) and chronic kidney disease (CKD) is associated with poor health outcomes and a high economic burden. Management of these conditions remains a significant challenge for current healthcare systems. The objective of this article is to describe the experiences of patients living with T2D and CKD and their thoughts on how communication between patients and their clinicians could be improved despite the multiple comorbidities that need to be addressed.

View Article and Find Full Text PDF

Non-alcoholic fatty liver disease (NAFLD) affects at least 25% of the general population and is an increasingly important cause of cirrhosis and hepatocellular carcinoma. Although it is the research focus of the hepatology field, it is clear that primary care physicians are seeing the majority of NAFLD patients and are in a pivotal position to provide quality care. In this article, we review the role of primary care in the management of NAFLD.

View Article and Find Full Text PDF

People with type 2 diabetes (T2D) who change their basal insulin (BI) may have variable persistence with therapy. Compared with first-generation (long-acting) BI analogs (insulin glargine 100U/mL [Gla-100]; insulin detemir [IDet]), second-generation (longer-acting) BI analogs (insulin glargine 300U/mL [Gla-300]; insulin degludec) have similar glycated hemoglobin (HbA1c) attainment and lowered hypoglycemia risk, which could impact treatment persistence. To compare persistence, adherence, health care resource utilization (HRU), and costs for individuals switching from neutral protamine Hagedorn insulin or a first-generation BI analog with either the second-generation BI, Gla-300, or an alternative first-generation BI analog (Gla-100 or IDet).

View Article and Find Full Text PDF

Background: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data.

Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia.

View Article and Find Full Text PDF

Background: ACHIEVE Control, a prospective, open-label, randomized, pragmatic, real-life study in insulin-naive people with type 2 diabetes (A1C 8.0-11.0%), demonstrated superiority of insulin glargine 300 units/mL (Gla-300) versus first-generation standard-of-care basal insulin (SOC-BI; glargine 100 units/mL or insulin detemir) in achieving individualized A1C targets without documented symptomatic (glucose ≤3.

View Article and Find Full Text PDF

Patients with chronic kidney disease (CKD) and type 2 diabetes (T2D) are at high risk of CKD progression and cardiovascular (CV) disease. Prevalence of CKD in patients with T2D is currently around 40% and continues to grow. The increasing number of people with CKD and T2D will ultimately have a significant impact upon health resource use and costs of care for people with T2D.

View Article and Find Full Text PDF

Objectives: We evaluated the effects of acquiring a flash continuous glucose monitoring (CGM) system in the population with type 2 diabetes (T2D) treated with basal or noninsulin therapy.

Study Design: This was a retrospective database analysis of the IBM MarketScan Commercial Claims and Medicare Supplemental databases that assessed rates of acute diabetes-related events (ADEs) and all-cause inpatient hospitalizations (ACHs) in a large population with T2D treated with basal insulin therapy or noninsulin medications. ADE and ACH rates 6 months prior to and 6 months post CGM acquisition were compared.

View Article and Find Full Text PDF

Numerous studies have demonstrated the clinical benefits of continuous glucose monitoring (CGM) use in individuals with type 1 diabetes and type 2 diabetes (T2D) who are treated with intensive insulin therapy. A growing body of evidence suggests that CGM use may also confer similar glycemic benefits in T2D individuals who are treated with less-intensive therapies. Investigators are also exploring the potential use of CGM as an aid in weight management.

View Article and Find Full Text PDF
Article Synopsis
  • Many individuals with type 2 diabetes struggle with glycemic control, particularly those on nonintensive treatment regimens, and the benefits of flash continuous glucose monitoring (CGM) in these cases have not been extensively studied.
  • A study analyzed data from over 1,000 adults with type 2 diabetes using the FreeStyle Libre flash CGM system, showing a significant decrease in average A1C levels from 10.1% to 8.6% after its prescription, particularly in those with the highest initial A1C.
  • The results suggest that flash CGM could effectively help improve glycemic control among a wider population of individuals with type 2 diabetes, warranting increased access to this technology.
View Article and Find Full Text PDF