Conventional electromagnetic navigation bronchoscopy and other guided bronchoscopic modalities have a very desirable safety profile, but their diagnostic yield is only 60-70% for pulmonary lesions. Recently, robotic-assisted bronchoscopy (RAB) platforms have been introduced to improve the diagnostic performance of bronchoscopic modalities. To determine the diagnostic performance and safety profile of RAB (using shape-sensing and electromagnetic navigation-based platforms) by performing a systematic review and meta-analysis.
View Article and Find Full Text PDFTracheobronchial neoplasms are much less common than lung parenchymal neoplasms but can be associated with significant morbidity and mortality. They include a broad differential of both malignant and benign entities, extending far beyond more commonly known pathologic conditions such as squamous cell carcinoma and carcinoid tumor. Airway lesions may be incidental findings at imaging or manifest with symptoms related to airway narrowing or mucosal irritation, invasion of adjacent structures, or distant metastatic disease.
View Article and Find Full Text PDFA 37-year-old woman with a medical history of myasthenia gravis resulting in progressive respiratory failure requiring continuous mechanical ventilation via tracheostomy, as well as multiple cardiac arrests leading to severe anoxic brain injury, was brought to the hospital from a nursing home because of difficulties with ventilation and oxygenation. On presentation to the ED, the patient was found to be agitated and tachypneic on a ventilator, generating low tidal volumes despite elevated peak airway pressures. Before the current presentation, the patient had been mechanically ventilated at a long-term acute care facility for the past 5 years.
View Article and Find Full Text PDFBackground: Endobronchial valve placement is a minimally invasive option for treatment of patients with severe emphysema, by reducing lung volumes in lobes with both poor ventilation and perfusion; ventilation is determined by emphysematous scores and perfusion by quantitative lung perfusion imaging. CT-based fissure identifying artificial intelligence algorithms have recently demonstrated enhanced quantification of the perfusion in a 5-lobar analysis. We hypothesized that this newly developed algorithm may offer greater utility in determining target treatment lobes by supplementing the radiographic risk stratification initiated by the conventional emphysematous scores alone.
View Article and Find Full Text PDFJ Bronchology Interv Pulmonol
October 2021
Interventional pulmonology is a growing field specializing in minimally invasive procedures of the mediastinum, lungs, airways, and pleura. These procedures have both diagnostic and therapeutic indications and are performed for benign and malignant diseases. Endobronchial US has been combined with transbronchial needle aspiration to extend tissue sampling beyond the airways and into the lungs and mediastinum.
View Article and Find Full Text PDFJ Community Hosp Intern Med Perspect
November 2019
: Endobronchial valves (EBV) are considered an innovation in the management of the persistent air leak (PAL). They offer a minimally invasive alternative to the traditional approach of pleurodesis and surgical intervention. We examined trends in mortality, length of stay (LOS), and resources utilization in patients who underwent EBV placement for PAL in the US.
View Article and Find Full Text PDFA 39-year-old female avid marathon runner presented with an abnormal chest radiograph obtained during preoperative evaluation prior to bilateral knee replacement because of osteoarthritis. As shown in Figure 1, chest radiograph revealed a focal nodular opacity in the middle lobe. She did not have any prior imaging for comparison.
View Article and Find Full Text PDFBackground: Percutaneous endoscopic gastrostomy (PEG) tube placement is a procedure frequently done in the intensive care unit. The use of a traditional endoscope can be difficult in cases of esophageal stenosis and theoretically confers an increased risk of infection due to its complex architecture. We describe a technique using the bronchoscope, which allows navigation through stenotic esophageal lesions and also minimizes the risk of endoscopy-associated infections.
View Article and Find Full Text PDFJ Bronchology Interv Pulmonol
January 2019
An understanding of thoracic computed tomographic anatomy is vital for procedural planning in bronchoscopy. When reviewing computed tomographic images in preparation for endobronchial ultrasound-directed staging for lung cancer, the presence of fluid in pericardial recesses can often be mistaken for mediastinal lymphadenopathy, potentially causing pitfalls in radiologic interpretation. We describe 2 cases of a high-riding superior aortic recess extending into right paratracheal lymph node station mimicking paratracheal lymphadenopathy.
View Article and Find Full Text PDFJ Bronchology Interv Pulmonol
July 2018
Background: Transbronchial needle aspiration (TBNA), often used to sample lymph nodes for lung cancer staging, is subject to sampling error even when performed with endobronchial ultrasound. Optical coherence tomography (OCT) is a high-resolution imaging modality that rapidly generates helical cross-sectional images. We aim to determine if needle-based OCT can provide microstructural information in lymph nodes that may be used to guide TBNA, and improve sampling error.
View Article and Find Full Text PDFPurpose Of Review: As the field of interventional pulmonology continues to expand and develop at a rapid pace, anesthesiologists are increasingly called upon to provide well tolerated anesthetic care during these procedures. These patients may not be candidates for surgical treatment and often have multiple comorbidities. It is important for anesthesiologists to familiarize themselves with these procedures and their associated risks and complications.
View Article and Find Full Text PDFObjectives: Bedside sonography for diagnosis of pneumothorax has been well described in emergency and trauma medicine literature. Its role in detection of iatrogenic pneumothorax has not been well studied. We describe the performance of bedside sonography for detection of procedure-related pneumothorax and highlight some limitations.
View Article and Find Full Text PDFJ Bronchology Interv Pulmonol
July 2012
Background: A case-control study was conducted to identify the possible risk factors for acute respiratory failure in patients undergoing bronchoscopy. We also aimed to estimate the financial costs incurred in the care of high-risk patients.
Methods: All hypoxic respiratory complications that occurred during bronchoscopy between January 2005 and March 2009 were reviewed.