The extraction of broken femoral nails can be a challenging procedure and surgeons should be familiar with many different techniques. This paper demonstrates a case study and new, simple and cost effective technique for the removal of broken cannulated femoral nails. Our technique uses two guide wires of variable diameter and had several key points of differentiation from previous methods.